Benchtop Ion meter for F, LBIM-A11 comes with (F) fluoride ion selective electrode for fluoride ion concentration measurement. This Ion meter comes with ± 0.5 % F.S. measurement accuracy. The direct ion concentration readout helps in elaborate measurement process. The system menu allows setting the 8 parameters like calibration points, stability condition etc. It can measure concentration in ppm, mg / L, mol / L. The mV measurement is used to check the performance of ion selective electrode.
Request QuoteIon measurement range | F range: 1 × 106M – saturation, 0.02 ppm to saturation |
Ion measurement accuracy | ± 0.5 % F.S. |
Resolution | 0.001, 0.01, 0.1, 1 |
Calibration points | 2 to 5 points |
Calibration solutions | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L |
mV range | (-1999.9) to 1999.9 mV |
mV accuracy | ± 0.2 mV |
mV resolution | 0.1 mV |
Temperature measurement range | 0 to 105 °C, 32 to 221 °F |
Temperature accuracy | ± 0.5 °C, ± 0.9 °F |
Temperature resolution | 0.1°C |
Temperature compensation | 0 to 100 °C, 32 to 212 °F |
Compensation mode | Manual or automatic |
Data hold function | Manual or automatic endpoint detection |
Reset function | Yes |
Stability condition | Low or high |
Calibration due | 0 to 31 days |
Power off | Manual or automatic (10,20,30 minutes) |
Memory | Stores up to 500 sets of data |
Output | USB communication interface |
Connector | BNC |
Display | LCD (130 × 110 mm) |
Power | DC 5 V, using AC adapter, AC 220 V / 50 Hz |
Dimension (L × W × H) | 210 × 188 × 60 mm |
Weight | 1.5 kg |
Benchtop Ion meter is used to measure the fluoride ion concentration present in potable water, D/W water, waste water and natural water resources using different ion concentration electrodes.
F fluoride Ion selective electrode
Temperature probe
Standard solution (1000 ppm)
Ionic strength adjuster (30 mL)
USB cable
DC 5 V Power adapter
Ion selective electrode: F range: 0.02 ppm to saturation
Ion standard solutions: 480 mL / bottle
Ionic strength adjuster: 480 mL / bottle
Temperature probe with sensor
Available Range :
Test Parameters : pH/ISE/Temp. (mV/pX) Ion measurement range : Na range: 0 to 19990 g/L Ion measurement range : Cu range: 0 to 19990 g/L Ion measurement range : I range: 0 to 19990 g/L Ion measurement range : NH range: 0 to 19990 g/L Ion measurement range : K range: 0 to 19990 g/LRelated Models :
Model | Ion measurement range | Ion measurement accuracy | Resolution | Calibration points | Calibration solutions | mV range | mV accuracy | mV resolution | Temperature measurement range | Temperature accuracy | Temperature resolution | Temperature compensation | Compensation mode | Data hold function | Reset function | Stability condition | Calibration due | Power off | Memory | Output | Connector | Display | Power | Dimension (L × W × H) | Weight |
LBIM-C15 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
LBIM-C11 | Na range: 0 to 19990 g/L | 0.005 | - | - | - | 1999.9 to1999.9 mV | 0.1% FS | 1 mV | -10 °C to 110.0 °C | 0.1 °C | 0.1 °C | - | - | - | - | - | - | - | - | - | - | - | DC12V/1A (with standard power adapter) | - | 600 Kg |
LBIM-C18 | Cu range: 0 to 19990 g/L | 0.005 | - | - | - | 1999.9 to 1999.9 mV | 0.1%FS | 1mV | -10 °C to 110.0 °C | 0.1 °C | 0.1 °C | - | - | - | - | - | - | - | - | - | - | - | DC 12 V/1 A (with standard power adapter) | - | - |
LBIM-C19 | I range: 0 to 19990 g/L | 0.005 | - | - | - | 1999.9 to 1999.9 mV | 0.1%FS | 1mV | -10 °C to 110.0 °C | 0.1 °C | 0.1 °C | - | - | - | - | - | - | - | - | - | - | - | DC 12 V/1 A (with standard power adapter) | - | 600 Kg |
LBIM-C17 | NH range: 0 to 19990 g/L | 0.005 | - | - | - | 1999.9 to 1999.9 mV | 0.1%FS | 1mV | -10 °C to 110.0°C | 0.1°C | 0.1°C | - | - | - | - | - | - | - | - | - | - | - | DC 12 V/1 A (with standard power adapter) | - | 600 Kg |
LBIM-C16 | K range: 0 to 19990 g/L | 0.005 | - | - | - | 1999.9 to 1999.9 mV | 0.1%FS | 1mV | -10 °C to 110.0°C | 0.1 °C | 0.1 °C | - | - | - | - | - | - | - | - | - | - | - | DC 12 V/1 A (with standard power adapter) | - | 600 Kg |
LBIM-A10 | Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm | ± 0.5 % F.S. | 0.001, 0.01, 0.1, 1 | 2 to 5 points | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L | (-1999.9) to 1999.9 mV | ± 0.2 mV | 0.1 mV | 0 to 105 °C, 32 to 221 °F | ± 0.5 °C, ± 0.9 °F | 0.1°C | 0 to 100 °C, 32 to 212 °F | Manual or automatic | Manual or automatic endpoint detection | Yes | Low or high | 0 to 31 days | Manual or automatic (10,20,30 minutes) | Stores up to 500 sets of data | USB communication interface | BNC | LCD (130 × 110 mm) | DC 5 V, using AC adapter, AC 220 V / 50 Hz | 210 × 188 × 60 mm | 1.5 kg |
LBIM-A11 | F range: 1 × 106M – saturation, 0.02 ppm to saturation | ± 0.5 % F.S. | 0.001, 0.01, 0.1, 1 | 2 to 5 points | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L | (-1999.9) to 1999.9 mV | ± 0.2 mV | 0.1 mV | 0 to 105 °C, 32 to 221 °F | ± 0.5 °C, ± 0.9 °F | 0.1°C | 0 to 100 °C, 32 to 212 °F | Manual or automatic | Manual or automatic endpoint detection | Yes | Low or high | 0 to 31 days | Manual or automatic (10,20,30 minutes) | Stores up to 500 sets of data | USB communication interface | BNC | LCD (130 × 110 mm) | DC 5 V, using AC adapter, AC 220 V / 50 Hz | 210 × 188 × 60 mm | 1.5 kg |
LBIM-A12 | Na range: 1 × 105 - 1 M, 0.1 - 23000 ppm | ± 0.5 % F.S. | 0.001, 0.01, 0.1, 1 | 2 to 5 points | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L | (-1999.9) to 1999.9 mV | ± 0.2 mV | 0.1 mV | 0 to 105 °C, 32 to 221 °F | ± 0.5 °C, ± 0.9 °F | 0.1°C | 0 to 100 °C, 32 to 212 °F | Manual or automatic | Manual or automatic endpoint detection | Yes | Low or high | 0 to 31 days | Manual or automatic (10,20,30 minutes) | Stores up to 500 sets of data | USB communication interface | BNC | LCD (130 × 110 mm) | DC 5 V, using AC adapter, AC 220 V / 50 Hz | 210 × 188 × 60 mm | 1.5 kg |
LBIM-A13 | Ca range: 5 × 107 - 1 M, 0.02 - 4000 ppm | ± 0.5 % F.S. | 0.001, 0.01, 0.1, 1 | 2 to 5 points | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L | (-1999.9) to 1999.9 mV | ± 0.2 mV | 0.1 mV | 0 to 105 °C, 32 to 221 °F | ± 0.5 °C, ± 0.9 °F | 0.1°C | 0 to 100 °C, 32 to 212 °F | Manual or automatic | Manual or automatic endpoint detection | Yes | Low or high | 0 to 31 days | Manual or automatic (10,20,30 minutes) | Stores up to 500 sets of data | USB communication interface | BNC | LCD (130 × 110 mm) | DC 5 V, using AC adapter, AC 220 V / 50 Hz | 210 × 188 × 60 mm | 1.5 kg |
LBIM-A14 | Br range: 5 × 106 - 1 M, 0.4 - 79900 ppm | ± 0.5 % F.S. | 0.001, 0.01, 0.1, 1 | 2 to 5 points | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L | (-1999.9) to 1999.9 mV | ± 0.2 mV | 0.1 mV | 0 to 105 °C, 32 to 221 °F | ± 0.5 °C, ± 0.9 °F | 0.1°C | 0 to 100 °C, 32 to 212 °F | Manual or automatic | Manual or automatic endpoint detection | Yes | Low or high | 0 to 31 days | Manual or automatic (10,20,30 minutes) | Stores up to 500 sets of data | USB communication interface | BNC | LCD (130 × 110 mm) | DC 5 V, using AC adapter, AC 220 V / 50 Hz | 210 × 188 × 60 mm | 1.5 kg |
LBIM-A15 | NH4 range: 5 × 106 – 1 M, 0.1 – 18000 ppm | ± 0.5 % F.S. | 0.001, 0.01, 0.1, 1 | 2 to 5 points | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L | (-1999.9) to 1999.9 mV | ± 0.2 mV | 0.1 mV | 0 to 105 °C, 32 to 221 °F | ± 0.5 °C, ± 0.9 °F | 0.1°C | 0 to 100 °C, 32 to 212 °F | Manual or automatic | Manual or automatic endpoint detection | Yes | Low or high | 0 to 31 days | Manual or automatic (10,20,30 minutes) | Stores up to 500 sets of data | USB communication interface | BNC | LCD (130 × 110 mm) | DC 5 V, using AC adapter, AC 220 V / 50 Hz | 210 × 188 × 60 mm | 1.5 kg |
LBIM-A20 | NH3 range: 1 × 106 - 1 M, 0.02 - 17000 ppm | ± 1 % F.S. | 0.001, 0.01, 0.1, 1 | 2 to 5 points | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L | (-1999.9) to 1999.9 mV | ± 0.2 mV | 0.1 mV | 0 to 105 °C, 32 to 221 °F | ± 0.5 °C, ± 0.9 °F | 0.1°C | 0 to 100 °C, 32 to 212 °F | Manual or automatic | Manual or automatic endpoint detection | Yes | Low or high | 0 to 31 days | Manual or automatic (10,20,30 minutes) | Stores up to 500 sets of data | USB communication interface | BNC | LCD (130 × 110 mm) | DC 5 V, using AC adapter, AC 220 V / 50 Hz | 210 × 188 × 60 mm | 1.5 kg |
LBIM-A21 | Cn range: 5 × 106 – 0.01 M, 0.2 – 260 ppm | ± 1 % F.S. | 0.001, 0.01, 0.1, 1 | 2 to 5 points | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L | (-1999.9) to 1999.9 mV | ± 0.2 mV | 0.1 mV | 0 to 105 °C, 32 to 221 °F | ± 0.5 °C, ± 0.9 °F | 0.1°C | 0 to 100 °C, 32 to 212 °F | Manual or automatic | Manual or automatic endpoint detection | Yes | Low or high | 0 to 31 days | Manual or automatic (10,20,30 minutes) | Stores up to 500 sets of data | USB communication interface | BNC | LCD (130 × 110 mm) | DC 5 V, using AC adapter, AC 220 V / 50 Hz | 210 × 188 × 60 mm | 1.5 kg |
LBIM-A22 | Ag range: 1 × 107 - 1 M, 0.01 - 107900 ppm | ± 1 % F.S. | 0.001, 0.01, 0.1, 1 | 2 to 5 points | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L | (-1999.9) to 1999.9 mV | ± 0.2 mV | 0.1 mV | 0 to 105 °C, 32 to 221 °F | ± 0.5 °C, ± 0.9 °F | 0.1°C | 0 to 100 °C, 32 to 212 °F | Manual or automatic | Manual or automatic endpoint detection | Yes | Low or high | 0 to 31 days | Manual or automatic (10,20,30 minutes) | Stores up to 500 sets of data | USB communication interface | BNC | LCD (130 × 110 mm) | DC 5 V, using AC adapter, AC 220 V / 50 Hz | 210 × 188 × 60 mm | 1.5 kg |
LBIM-A23 | K range: 1×106 - 1M, 0.04 -39000 ppm | ± 1 % F.S. | 0.001, 0.01, 0.1, 1 | 2 to 5 points | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L | (-1999.9) to 1999.9 mV | ± 0.2 mV | 0.1 mV | 0 to 105 °C, 32 to 221 °F | ± 0.5 °C, ± 0.9 °F | 0.1°C | 0 to 100 °C, 32 to 212 °F | Manual or automatic | Manual or automatic endpoint detection | Yes | Low or high | 0 to 31 days | Manual or automatic (10,20,30 minutes) | Stores up to 500 sets of data | USB communication interface | BNC | LCD (130 × 110 mm) | DC 5 V, using AC adapter, AC 220 V / 50 Hz | 210 × 188 × 60 mm | 1.5 kg |
LBIM-A24 | S range: 1×107 - 1M, 0.003-32100 ppm | ± 1 % F.S. | 0.001, 0.01, 0.1, 1 | 2 to 5 points | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L | (-1999.9) to 1999.9 mV | ± 0.2 mV | 0.1 mV | 0 to 105 °C, 32 to 221 °F | ± 0.5 °C, ± 0.9 °F | 0.1°C | 0 to 100 °C, 32 to 212 °F | Manual or automatic | Manual or automatic endpoint detection | Yes | Low or high | 0 to 31 days | Manual or automatic (10,20,30 minutes) | Stores up to 500 sets of data | USB communication interface | BNC | LCD (130 × 110 mm) | DC 5 V, using AC adapter, AC 220 V / 50 Hz | 210 × 188 × 60 mm | 1.5 kg |
LBIM-A25 | Pb range: 1×108 – 0.1M, 0.2-20700 ppm | ± 1 % F.S. | 0.001, 0.01, 0.1, 1 | 2 to 5 points | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L | (-1999.9) to 1999.9 mV | ± 0.2 mV | 0.1 mV | 0 to 105 °C, 32 to 221 °F | ± 0.5 °C, ± 0.9 °F | 0.1°C | 0 to 100 °C, 32 to 212 °F | Manual or automatic | Manual or automatic endpoint detection | Yes | Low or high | 0 to 31 days | Manual or automatic (10,20,30 minutes) | Stores up to 500 sets of data | USB communication interface | BNC | LCD (130 × 110 mm) | DC 5 V, using AC adapter, AC 220 V / 50 Hz | 210 × 188 × 60 mm | 1.5 kg |
LBIM-A26 | I range: 1×108- 1M, 0.06 -127000 ppm | ± 1 % F.S. | 0.001, 0.01, 0.1, 1 | 2 to 5 points | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L | (-1999.9) to 1999.9 mV | ± 0.2 mV | 0.1 mV | 0 to 105 °C, 32 to 221 °F | ± 0.5 °C, ± 0.9 °F | 0.1°C | 0 to 100 °C, 32 to 212 °F | Manual or automatic | Manual or automatic endpoint detection | Yes | Low or high | 0 to 31 days | Manual or automatic (10,20,30 minutes) | Stores up to 500 sets of data | USB communication interface | BNC | LCD (130 × 110 mm) | DC 5 V, using AC adapter, AC 220 V / 50 Hz | 210 × 188 × 60 mm | 1.5 kg |
LBIM-A27 | Cu range: 1×108 - 1M, 0.06-6400 ppm | ± 1 % F.S. | 0.001, 0.01, 0.1, 1 | 2 to 5 points | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L | (-1999.9) to 1999.9 mV | ± 0.2 mV | 0.1 mV | 0 to 105 °C, 32 to 221 °F | ± 0.5 °C, ± 0.9 °F | 0.1°C | 0 to 100 °C, 32 to 212 °F | Manual or automatic | Manual or automatic endpoint detection | Yes | Low or high | 0 to 31 days | Manual or automatic (10,20,30 minutes) | Stores up to 500 sets of data | USB communication interface | BNC | LCD (130 × 110 mm) | DC 5 V, using AC adapter, AC 220 V / 50 Hz | 210 × 188 × 60 mm | 1.5 kg |
LBIM-A28 | Cd range: 1×106– 1M, 0.01-11200 ppm | ± 1 % F.S. | 0.001, 0.01, 0.1, 1 | 2 to 5 points | 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L | (-1999.9) to 1999.9 mV | ± 0.2 mV | 0.1 mV | 0 to 105 °C, 32 to 221 °F | ± 0.5 °C, ± 0.9 °F | 0.1°C | 0 to 100 °C, 32 to 212 °F | Manual or automatic | Manual or automatic endpoint detection | Yes | Low or high | 0 to 31 days | Manual or automatic (10,20,30 minutes) | Stores up to 500 sets of data | USB communication interface | BNC | LCD (130 × 110 mm) | DC 5 V, using AC adapter, AC 220 V / 50 Hz | 210 × 188 × 60 mm | 1.5 kg |
LBIM-C14 | Br range: 0 to 19990 g/L | 0.005 | - | - | - | 1999.9 to1999.9 mV | 0.1% FS | 1 mV | -10 °C to 110.0 °C | 0.1 °C | 0.1 °C | - | - | - | - | - | - | - | - | - | - | - | DC12V/1A (with standard power adapter) | - | 600 Kg |
LBIM-C13 | Ca range: 0 to 19990 g/L | 0.005 | - | - | - | 1999.9 to1999.9 mV | 0.1% FS | 1 mV | -10 °C to 110.0 °C | 0.1 °C | 0.1 °C | - | - | - | - | - | - | - | - | - | - | - | DC12V/1A (with standard power adapter) | - | 600 Kg |
LBIM-C12 | Cl range: 0 to 19990 g/L | 0.005 | - | - | - | 1999.9 to1999.9 mV | 0.1% FS | 1 mV | -10 °C to 110.0 °C | 0.1 °C | 0.1 °C | - | - | - | - | - | - | - | - | - | - | - | DC12V/1A (with standard power adapter) | - | 600 Kg |
LBIM-C10 | F range: 0 to 19990 g/L | 0.005 | - | - | - | 1999.9 to1999.9 mV | 0.1% FS | 1 mV | -10 °C to 110.0 °C | 0.1 °C | 0.1 °C | - | - | - | - | - | - | - | - | - | - | - | DC12V/1A (with standard power adapter) | - | 600 Kg |