Benchtop Ion meter for Na, LBIM-A12

Benchtop Ion meter for Na, LBIM-A12

Benchtop Ion meter for Na, LBIM-A12 comes with (Na) sodium ion selective electrode for sodium ion concentration measurement. This Ion meter comes with ± 0.5 % F.S. measurement accuracy. The direct ion concentration readout helps in elaborate measurement process. The system menu allows setting the 8 parameters like calibration points, stability condition etc. It can measure concentration in ppm, mg / L, mol / L. The mV measurement is used to check the performance of ion selective electrode.

Request Quote
Ion measurement range Na range: 1 × 105 - 1 M, 0.1 - 23000 ppm
Ion measurement accuracy ± 0.5 % F.S.
Resolution 0.001, 0.01, 0.1, 1
Calibration points 2 to 5 points
Calibration solutions 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L
mV range (-1999.9) to 1999.9 mV
mV accuracy ± 0.2 mV
mV resolution 0.1 mV
Temperature measurement range 0 to 105 °C, 32 to 221 °F
Temperature accuracy ± 0.5 °C, ± 0.9 °F
Temperature resolution 0.1°C
Temperature compensation 0 to 100 °C, 32 to 212 °F
Compensation mode Manual or automatic
Data hold function Manual or automatic endpoint detection
Reset function Yes
Stability condition Low or high
Calibration due 0 to 31 days
Power off Manual or automatic (10,20,30 minutes)
Memory Stores up to 500 sets of data
Output USB communication interface
Connector BNC
Display LCD (130 × 110 mm)
Power DC 5 V, using AC adapter, AC 220 V / 50 Hz
Dimension (L × W × H) 210 × 188 × 60 mm
Weight 1.5 kg
  • Large LCD display
  • 2 - 5 points calibration from low to high concentration
  • Direct ion concentration readout for elaborate measurement process
  • Selectable concentration units from ppm, mg / L, mol / L
  • mV measurements to check the performance of ion selective electrode
  • Temperature compensation provides accurate reading over the entire range
  • Stability indicator to show current measurement status
  • Calibration due reminder for regular calibration of the meter
  • Auto hold function to freeze stable reading for better viewing & recording
  • Automatic electrode diagnosis shows the slope of the sensor
  • Reset setting function
  • Expanded memory stores and recalls up to 500 readings
  • Built –in real time clock stamps
  • USB communication interface to transfer stored data to PC

Benchtop Ion meter is used to measure the sodium ion concentration present in potable water, D/W water, waste water and natural water resources using different ion concentration electrodes.

Na sodium Ion selective electrode
Temperature probe
Standard solution (1000 ppm)
Ionic strength adjuster (30 mL)
USB cable
DC 5 V Power adapter

Ion selective electrode: Na range: 0.1 - 23000 ppm
Ion standard solutions: 480 mL / bottle
Ionic strength adjuster: 480 mL / bottle
Temperature probe with sensor

Compare Models

Model Ion measurement range Ion measurement accuracy Resolution Calibration points Calibration solutions mV range mV accuracy mV resolution Temperature measurement range Temperature accuracy Temperature resolution Temperature compensation Compensation mode Data hold function Reset function Stability condition Calibration due Power off Memory Output Connector Display Power Dimension (L × W × H) Weight
LBIM-C15 - - - - - - - - - - - - - - - - - - - - - - - - -
LBIM-C11 Na range: 0 to 19990 g/L 0.005 - - - 1999.9 to1999.9 mV 0.1% FS 1 mV -10 °C to 110.0 °C 0.1 °C 0.1 °C - - - - - - - - - - - DC12V/1A (with standard power adapter) - 600 Kg
LBIM-C18 Cu range: 0 to 19990 g/L 0.005 - - - 1999.9 to 1999.9 mV 0.1%FS 1mV -10 °C to 110.0 °C 0.1 °C 0.1 °C - - - - - - - - - - - DC 12 V/1 A (with standard power adapter) - -
LBIM-C19 I range: 0 to 19990 g/L 0.005 - - - 1999.9 to 1999.9 mV 0.1%FS 1mV -10 °C to 110.0 °C 0.1 °C 0.1 °C - - - - - - - - - - - DC 12 V/1 A (with standard power adapter) - 600 Kg
LBIM-C17 NH range: 0 to 19990 g/L 0.005 - - - 1999.9 to 1999.9 mV 0.1%FS 1mV -10 °C to 110.0°C 0.1°C 0.1°C - - - - - - - - - - - DC 12 V/1 A (with standard power adapter) - 600 Kg
LBIM-C16 K range: 0 to 19990 g/L 0.005 - - - 1999.9 to 1999.9 mV 0.1%FS 1mV -10 °C to 110.0°C 0.1 °C 0.1 °C - - - - - - - - - - - DC 12 V/1 A (with standard power adapter) - 600 Kg
LBIM-A10 Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm ± 0.5 % F.S. 0.001, 0.01, 0.1, 1 2 to 5 points 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L (-1999.9) to 1999.9 mV ± 0.2 mV 0.1 mV 0 to 105 °C, 32 to 221 °F ± 0.5 °C, ± 0.9 °F 0.1°C 0 to 100 °C, 32 to 212 °F Manual or automatic Manual or automatic endpoint detection Yes Low or high 0 to 31 days Manual or automatic (10,20,30 minutes) Stores up to 500 sets of data USB communication interface BNC LCD (130 × 110 mm) DC 5 V, using AC adapter, AC 220 V / 50 Hz 210 × 188 × 60 mm 1.5 kg
LBIM-A11 F range: 1 × 106M – saturation, 0.02 ppm to saturation ± 0.5 % F.S. 0.001, 0.01, 0.1, 1 2 to 5 points 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L (-1999.9) to 1999.9 mV ± 0.2 mV 0.1 mV 0 to 105 °C, 32 to 221 °F ± 0.5 °C, ± 0.9 °F 0.1°C 0 to 100 °C, 32 to 212 °F Manual or automatic Manual or automatic endpoint detection Yes Low or high 0 to 31 days Manual or automatic (10,20,30 minutes) Stores up to 500 sets of data USB communication interface BNC LCD (130 × 110 mm) DC 5 V, using AC adapter, AC 220 V / 50 Hz 210 × 188 × 60 mm 1.5 kg
LBIM-A12 Na range: 1 × 105 - 1 M, 0.1 - 23000 ppm ± 0.5 % F.S. 0.001, 0.01, 0.1, 1 2 to 5 points 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L (-1999.9) to 1999.9 mV ± 0.2 mV 0.1 mV 0 to 105 °C, 32 to 221 °F ± 0.5 °C, ± 0.9 °F 0.1°C 0 to 100 °C, 32 to 212 °F Manual or automatic Manual or automatic endpoint detection Yes Low or high 0 to 31 days Manual or automatic (10,20,30 minutes) Stores up to 500 sets of data USB communication interface BNC LCD (130 × 110 mm) DC 5 V, using AC adapter, AC 220 V / 50 Hz 210 × 188 × 60 mm 1.5 kg
LBIM-A13 Ca range: 5 × 107 - 1 M, 0.02 - 4000 ppm ± 0.5 % F.S. 0.001, 0.01, 0.1, 1 2 to 5 points 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L (-1999.9) to 1999.9 mV ± 0.2 mV 0.1 mV 0 to 105 °C, 32 to 221 °F ± 0.5 °C, ± 0.9 °F 0.1°C 0 to 100 °C, 32 to 212 °F Manual or automatic Manual or automatic endpoint detection Yes Low or high 0 to 31 days Manual or automatic (10,20,30 minutes) Stores up to 500 sets of data USB communication interface BNC LCD (130 × 110 mm) DC 5 V, using AC adapter, AC 220 V / 50 Hz 210 × 188 × 60 mm 1.5 kg
LBIM-A14 Br range: 5 × 106 - 1 M, 0.4 - 79900 ppm ± 0.5 % F.S. 0.001, 0.01, 0.1, 1 2 to 5 points 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L (-1999.9) to 1999.9 mV ± 0.2 mV 0.1 mV 0 to 105 °C, 32 to 221 °F ± 0.5 °C, ± 0.9 °F 0.1°C 0 to 100 °C, 32 to 212 °F Manual or automatic Manual or automatic endpoint detection Yes Low or high 0 to 31 days Manual or automatic (10,20,30 minutes) Stores up to 500 sets of data USB communication interface BNC LCD (130 × 110 mm) DC 5 V, using AC adapter, AC 220 V / 50 Hz 210 × 188 × 60 mm 1.5 kg
LBIM-A15 NH4 range: 5 × 106 – 1 M, 0.1 – 18000 ppm ± 0.5 % F.S. 0.001, 0.01, 0.1, 1 2 to 5 points 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L (-1999.9) to 1999.9 mV ± 0.2 mV 0.1 mV 0 to 105 °C, 32 to 221 °F ± 0.5 °C, ± 0.9 °F 0.1°C 0 to 100 °C, 32 to 212 °F Manual or automatic Manual or automatic endpoint detection Yes Low or high 0 to 31 days Manual or automatic (10,20,30 minutes) Stores up to 500 sets of data USB communication interface BNC LCD (130 × 110 mm) DC 5 V, using AC adapter, AC 220 V / 50 Hz 210 × 188 × 60 mm 1.5 kg
LBIM-A20 NH3 range: 1 × 106 - 1 M, 0.02 - 17000 ppm ± 1 % F.S. 0.001, 0.01, 0.1, 1 2 to 5 points 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L (-1999.9) to 1999.9 mV ± 0.2 mV 0.1 mV 0 to 105 °C, 32 to 221 °F ± 0.5 °C, ± 0.9 °F 0.1°C 0 to 100 °C, 32 to 212 °F Manual or automatic Manual or automatic endpoint detection Yes Low or high 0 to 31 days Manual or automatic (10,20,30 minutes) Stores up to 500 sets of data USB communication interface BNC LCD (130 × 110 mm) DC 5 V, using AC adapter, AC 220 V / 50 Hz 210 × 188 × 60 mm 1.5 kg
LBIM-A21 Cn range: 5 × 106 – 0.01 M, 0.2 – 260 ppm ± 1 % F.S. 0.001, 0.01, 0.1, 1 2 to 5 points 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L (-1999.9) to 1999.9 mV ± 0.2 mV 0.1 mV 0 to 105 °C, 32 to 221 °F ± 0.5 °C, ± 0.9 °F 0.1°C 0 to 100 °C, 32 to 212 °F Manual or automatic Manual or automatic endpoint detection Yes Low or high 0 to 31 days Manual or automatic (10,20,30 minutes) Stores up to 500 sets of data USB communication interface BNC LCD (130 × 110 mm) DC 5 V, using AC adapter, AC 220 V / 50 Hz 210 × 188 × 60 mm 1.5 kg
LBIM-A22 Ag range: 1 × 107 - 1 M, 0.01 - 107900 ppm ± 1 % F.S. 0.001, 0.01, 0.1, 1 2 to 5 points 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L (-1999.9) to 1999.9 mV ± 0.2 mV 0.1 mV 0 to 105 °C, 32 to 221 °F ± 0.5 °C, ± 0.9 °F 0.1°C 0 to 100 °C, 32 to 212 °F Manual or automatic Manual or automatic endpoint detection Yes Low or high 0 to 31 days Manual or automatic (10,20,30 minutes) Stores up to 500 sets of data USB communication interface BNC LCD (130 × 110 mm) DC 5 V, using AC adapter, AC 220 V / 50 Hz 210 × 188 × 60 mm 1.5 kg
LBIM-A23 K range: 1×106 - 1M, 0.04 -39000 ppm ± 1 % F.S. 0.001, 0.01, 0.1, 1 2 to 5 points 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L (-1999.9) to 1999.9 mV ± 0.2 mV 0.1 mV 0 to 105 °C, 32 to 221 °F ± 0.5 °C, ± 0.9 °F 0.1°C 0 to 100 °C, 32 to 212 °F Manual or automatic Manual or automatic endpoint detection Yes Low or high 0 to 31 days Manual or automatic (10,20,30 minutes) Stores up to 500 sets of data USB communication interface BNC LCD (130 × 110 mm) DC 5 V, using AC adapter, AC 220 V / 50 Hz 210 × 188 × 60 mm 1.5 kg
LBIM-A24 S range: 1×107 - 1M, 0.003-32100 ppm ± 1 % F.S. 0.001, 0.01, 0.1, 1 2 to 5 points 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L (-1999.9) to 1999.9 mV ± 0.2 mV 0.1 mV 0 to 105 °C, 32 to 221 °F ± 0.5 °C, ± 0.9 °F 0.1°C 0 to 100 °C, 32 to 212 °F Manual or automatic Manual or automatic endpoint detection Yes Low or high 0 to 31 days Manual or automatic (10,20,30 minutes) Stores up to 500 sets of data USB communication interface BNC LCD (130 × 110 mm) DC 5 V, using AC adapter, AC 220 V / 50 Hz 210 × 188 × 60 mm 1.5 kg
LBIM-A25 Pb range: 1×108 – 0.1M, 0.2-20700 ppm ± 1 % F.S. 0.001, 0.01, 0.1, 1 2 to 5 points 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L (-1999.9) to 1999.9 mV ± 0.2 mV 0.1 mV 0 to 105 °C, 32 to 221 °F ± 0.5 °C, ± 0.9 °F 0.1°C 0 to 100 °C, 32 to 212 °F Manual or automatic Manual or automatic endpoint detection Yes Low or high 0 to 31 days Manual or automatic (10,20,30 minutes) Stores up to 500 sets of data USB communication interface BNC LCD (130 × 110 mm) DC 5 V, using AC adapter, AC 220 V / 50 Hz 210 × 188 × 60 mm 1.5 kg
LBIM-A26 I range: 1×108- 1M, 0.06 -127000 ppm ± 1 % F.S. 0.001, 0.01, 0.1, 1 2 to 5 points 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L (-1999.9) to 1999.9 mV ± 0.2 mV 0.1 mV 0 to 105 °C, 32 to 221 °F ± 0.5 °C, ± 0.9 °F 0.1°C 0 to 100 °C, 32 to 212 °F Manual or automatic Manual or automatic endpoint detection Yes Low or high 0 to 31 days Manual or automatic (10,20,30 minutes) Stores up to 500 sets of data USB communication interface BNC LCD (130 × 110 mm) DC 5 V, using AC adapter, AC 220 V / 50 Hz 210 × 188 × 60 mm 1.5 kg
LBIM-A27 Cu range: 1×108 - 1M, 0.06-6400 ppm ± 1 % F.S. 0.001, 0.01, 0.1, 1 2 to 5 points 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L (-1999.9) to 1999.9 mV ± 0.2 mV 0.1 mV 0 to 105 °C, 32 to 221 °F ± 0.5 °C, ± 0.9 °F 0.1°C 0 to 100 °C, 32 to 212 °F Manual or automatic Manual or automatic endpoint detection Yes Low or high 0 to 31 days Manual or automatic (10,20,30 minutes) Stores up to 500 sets of data USB communication interface BNC LCD (130 × 110 mm) DC 5 V, using AC adapter, AC 220 V / 50 Hz 210 × 188 × 60 mm 1.5 kg
LBIM-A28 Cd range: 1×106– 1M, 0.01-11200 ppm ± 1 % F.S. 0.001, 0.01, 0.1, 1 2 to 5 points 0.001, 0.01, 0.1, 1, 10, 100, 1000, 10000 ppm, mol / L, mg / L (-1999.9) to 1999.9 mV ± 0.2 mV 0.1 mV 0 to 105 °C, 32 to 221 °F ± 0.5 °C, ± 0.9 °F 0.1°C 0 to 100 °C, 32 to 212 °F Manual or automatic Manual or automatic endpoint detection Yes Low or high 0 to 31 days Manual or automatic (10,20,30 minutes) Stores up to 500 sets of data USB communication interface BNC LCD (130 × 110 mm) DC 5 V, using AC adapter, AC 220 V / 50 Hz 210 × 188 × 60 mm 1.5 kg
LBIM-C14 Br range: 0 to 19990 g/L 0.005 - - - 1999.9 to1999.9 mV 0.1% FS 1 mV -10 °C to 110.0 °C 0.1 °C 0.1 °C - - - - - - - - - - - DC12V/1A (with standard power adapter) - 600 Kg
LBIM-C13 Ca range: 0 to 19990 g/L 0.005 - - - 1999.9 to1999.9 mV 0.1% FS 1 mV -10 °C to 110.0 °C 0.1 °C 0.1 °C - - - - - - - - - - - DC12V/1A (with standard power adapter) - 600 Kg
LBIM-C12 Cl range: 0 to 19990 g/L 0.005 - - - 1999.9 to1999.9 mV 0.1% FS 1 mV -10 °C to 110.0 °C 0.1 °C 0.1 °C - - - - - - - - - - - DC12V/1A (with standard power adapter) - 600 Kg
LBIM-C10 F range: 0 to 19990 g/L 0.005 - - - 1999.9 to1999.9 mV 0.1% FS 1 mV -10 °C to 110.0 °C 0.1 °C 0.1 °C - - - - - - - - - - - DC12V/1A (with standard power adapter) - 600 Kg

Most Viewed

Customer Enquiry Form

Ask Expert

Address: Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608

Copyright © 2023 Labtron Equipment Ltd. All rights reserved.