info@labtron.com +44 2080 043608
Electronic Tearing tester TP-J21

Electronic Tearing tester TP-J21

Electronic Tearing tester TP-J21 is adopted with advanced and supporting components, single-chip microcomputer and has reasonable structure and multi- function design. The variety of parameters included in electronic tester are standard test, conversion, adjustment, display, memory, print and other functions. This electronic tearing resistance tester is suitable for all kinds of paper and some kinds of cardboards.

Request Quote
Capacity 10 -16000 mN
Resolution 0.1 mN
Tearing arm 104 ± 1 mm
Tearing angle 27.5° ± 5°
Chips distance 180 mm
Clamp- paper 2.8 ± 0.3 mm
Resection length 20 ± 0.5 mm
Weight 20 kg
  • High precision angle sensor to ensure rapid collection of data
  • Micro-printer, easy to print test report
  • Flexible configurations to reach different functions
  • Touch screen display
  • Connected to PC for data transfer
  • Compact structure design
  • Easy for maintenance

Electronic Tearing tester is used to test tearing strength of paper material, paper and sheets, cardboards etc. in paper and packaging, textile industry.

Compare Models

Model Measuring range Capacity Resolution Indication error Tearing arm Tearing angle Chips distance Clamp- paper Resection length Tearing distance Frictional resistance Pyramid dimension Platen Size Operating stroke Compression speed Impact angle Unit Error Sample amount Speed adjustment range Track & force speed in stacking test Test area Area differential pressure Inner diameter of grip ring Dimension Weight Power supply
TP-A10 - - - - - - - - - - - - - - - - - - - - - - - - - - 220 V ± 10 %, 50 Hz
TP-A11 - - - ≤ 0.5 % - - - - - - - - - - - - - - - - - - - - - - 220 V ± 10 %, 50 Hz
TP-B10 (1-500) mN.m (divided into 7 small ranges) - - 0.02 - - - - - - - - - - - - - - - - - - - - - - 220 V ± 10 %, 50 Hz
TP-B11 0 to 30, 0 to 100 N,0 to 300 N - - - - - - - - - - - - - - - - - - - - - - - - - 220 V ± 10 %, 50 Hz
TP-B12 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N - - - - - - - - - - - - - - - - - - - - - - - - - 220 V ± 10 %, 50 Hz
TP-B20 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N - - - - - - - - - - - - - - - - - - - - - - - - - 220 V ± 10 %, 50 Hz
TP-C10 - - - - - - - - - - - - - - - - - - - - - - - - 450×250×1100 mm - -
TP-C20 - - - - - - - - - - - - - - - - - - - - - - - - 420×250×380 mm - -
TP-C21 - - - - - - - - - - - - - - - - - - - - - - - - 270×400×300 mm - -
TP-C30 - - - - - - - - - - - - - - - - - - - - - - - - 240×288×435 mm - -
TP-D10 - - - - - - - - - - - - - - - - - - - - - - - - - - -
TP-E10 - - - - - - - - - - - - - - - - - - - - - - - - 200×230×350 mm 15 kg AC220 V ± 10 % , 50 Hz
TP-E20 0 to 4 mm - - - - - - - - - - - - - - - - - - - - - - - 233×160×120 mm 5.5 kg -
TP-E21 0 to 20 mm - - - - - - - - - - - - - - - - - - - - - - - 233×160×120 mm 5.5 kg -
TP-F10 - - - - - - - - - - - - - - - - - - - - - - - - 275×302×297 mm 25 kg AC220 V ± 10 % , 50 Hz
TP-G10 - - - - - - - - - - - - - - - - - - - - - - - - 240×520×70 mm 4 kg -
TP-H10 10 to 1000 mN - - - - - - - - - - - - - - - - - - - - - - - 570×410×200 mm 33 kg AC220 V ± 10 % , 50 Hz
TP-I10 0.1 to 10 kN - - < ± 1% - - - - - - - - 500×500 mm (customized) 500 mm (customized) 10 mm/ min - - - - 2 to 100 mm/ min 2 mm/ min - - - - - AC220 V ± 10 % , 50 Hz
TP-I11 1 to 50 kN - - < ± 1% - - - - - - - - 800×800 mm/ 1000×1000 mm/ 1200×1200 mm/ 1500×1500 mm (customized) 800 mm/ 1000 mm/ 1200 mm/ 1500 mm (customized) 10 mm/ min - - - - 2 to 100 mm/ min 2 mm/ min - - - - - AC220 V ± 10 % , 50 Hz
TP-J10 0 to 1000 ml/min - - - - - - - - - - - - - - - - - - - - 10 ± 0.02 cm2 1 ± 0.01 kPa 35.68 ± 0.05 mm 410×300×1160 mm About 15kg -
TP-J11 - A: 20 to 500 J/m2 B: 500 to 1000 J/m2 - - - - - - - - - - - - - 90° Lb-ft/in2  J/m2 A: ± 1 J/m2 B: ± 2 J/m2 5 pcs - - - - - 700×340×600 mm 92    g -
TP-J12 A (1 to 6) J indicating error ± 0.05 J
B (1 to 12) J indicating error ± 0.05 J
C (1 to 24) J indicating error ± 0.05 J
D (1 to 48) J indicating error ± 0.05 J
The indicating errors w.r.t measurement range of 20 to 80 %
- - - - - - - - - <0.25 J Three sides: 60×60×60 mm, height 25 ± 0.7 mm, Arris edge fillet radius 1.5 ± 0.1 mm - - - - - - - - - - - - 800×470×840 mm 185 kg AC220 V ± 10 % , 50 Hz
TP-J20 0 to 1000 mN - 0.1 mN ± 1 % 104 ± 1 mm 27.5° ± 0.5° - - - 43 ± 0.5 mm - - - - - - - - - - - - - - - - -
TP-J21 - 10 -16000 mN 0.1 mN - 104 ± 1 mm 27.5° ± 5° 180 mm 2.8 ± 0.3 mm 20 ± 0.5 mm - - - - - - - - - - - - - - - - 20 kg -
TP-K10 - - - - - - - - - - - - - - 170 ± 15 ml/min - - - - - - - - - - - AC220 V ± 10 % , 50 Hz
TP-K11 - - 0.01 kPa - - - - - - - - - - - 95 ± 5 ml/min - - - - - - - - - - - AC220 V ± 10 % , 50 Hz
TP-L10 - - 1 N - - - - - - - - - - - - - - - - - - - - - - - AC220 V ± 10 % , 50 Hz
TP-L20 - - - - - - - - - - - - - - - - - - - - - - - - - - AC220 V ± 10 % , 50 Hz
TP-M10 - - - - - - - - - - - - - - - - - - - - - - - - - - AC220 V ± 10 % , 50 Hz
TP-E30 0 to 5 mm - - ± 0.0025 mm or ± 0.5 % - - - - - - - - - - - - - - - - - - - - - 25 Kg -