Wavelength range | 180 – 900 nm |
Spectral Bandwidth | 0 nm, 0.2 nm, 0.4 nm, 1.0 nm, 2.0 nm (5 steps with automatic changeover) |
Wavelength accuracy | ≤ 0.15 nm |
Wavelength repeatability | ± 0.1 nm |
Baseline drift | ≤ ± 0.002 Abs / 30 min (Static) ≤ ± 0.005 Abs / 30 mins (Dynamic) |
Absorbance Range | 0 - 4 A |
Lamp holder | ≤ 3 lamps automatic turret, automatic alignment |
Lamp power supply mode | pulsed power supply |
Optical System | large 1800 /mm grating ruling, full closed optical system |
Atomization Chamber | Polymer explosion-proof spray chamber |
Characteristic concentration (Cu) | 0.015 μg / mL / 1 % |
Detection Limit (Cu) | 0.002 μg/mL |
Burner | Full titanium combustion head, 50 mm or 100 mm general combustion head |
Nebulizer | Atomizer efficient glass atomizer,can also be customized |
Precision | RSD ≤ 0.5 % |
Ignition Type | Microcomputer control, automatic ignition |
Gas Control | Automatic gas control system |
Measurement | Flame method, Hydride generation-Atomic absorption method |
Concentration calculation | Standard curve method(1 - 3 times curve), automatic fitting |
The number of repeated measurements | 1 to 99, automatic calculation of average concentration, standard deviation, relative standard deviation. |
Print results | Print the final stages of test data or analysis. The results can be exported into Excel worksheet. |
Download catalog for
Atomic Absorption Spectrophotometer LAAS-A21 Catalog
Available Range :
Atomic Absorption Spectrophotometer LAAS-A20 : 180 - 900 nm Atomic Absorption Spectrophotometer LAAS-A21 : 180 – 900 nm Atomic Absorption Spectrophotometer LAAS-A23 : 185 to 900 nm Atomic Absorption Spectrophotometer LAAS-A11 : 190 to 900 nm Flame Atomic Absorption Spectrophotometer LAAS-A15 : 190 to 900nm Atomic Absorption Spectrophotometer LAAS-A24 : 190nm to 900nmSimilar Products
Our LAAS-A21 can accommodate varied customer requests for different kinds of elemental testing because it has a built-in flame, graphite furnace, and hydride generating system.
Yes, our LAAS-A21 can automatically switch between flame and graphite furnace operating modes, providing flexibility and convenience for different types of analysis.
Our LAAS-A21 is equipped with an automatic gas control system, which precisely regulates gas flows required for various types of analysis. This system ensures accuracy and safety by automatically adjusting gas parameters according to the selected analysis mode, guaranteeing optimal conditions for reliable results.
An analytical tool called an Atomic Absorption Spectrophotometer (AAS) uses the light that each element's atom absorbs to determine the concentration of that element in a sample.
The basis of spectrophotometry is the light uptake by unbound atoms in a gaseous state. An excited state is created when atoms in the ground state absorb light energy at particular wavelengths. Analyte content in the sample can be calculated by determining the amount of light consumed.
The components include an atomizer (commonly used atomizers are Flame atomizers and Electro thermal atomizers), a Radiation source, and a spectrophotometer.
The hollow cathode lamp in atomic absorption spectrophotometer emits distinctive light at particular wavelengths that match the target analyte. This guarantees that the analyte atoms are excited selectively, resulting in exact and reliable readings.
Labtron’s Atomic Absorption Spectrophotometers boast flexible atomization technologies, accurate optical systems, a titanium combustion head, and a polymer explosion-proof spray chamber. These elements guarantee accurate and effective trace element analysis, along with improved safety and longevity.