| Wavelength range | 185 to 900 nm |
| Spectral Bandwidth | 0.1 nm,0.2 nm,0.4 nm, 0.7 nm, 1.0 nm, 1.4 nm, 2.0 nm automatic setting |
| Wavelength accuracy | ± 0.15 nm |
| Wavelength repeatability | < 0.1 nm |
| Baseline Stability | ≤ ± 0.002 A/30 min (Static), ≤ ± 0.004 A/30 min (Dynamic) |
| Absorbance Range | 0 to 4 A |
| The Program | Automatic temperature controls up to 20 order |
| Temperature Range | Room temperature to 3000 ℃ |
| Detector | Imported photomultiplier tube |
| Heating Mode | Vertical heating |
| Temperature Control Method | Vertical optical temperature monitoring graphite tube wall temperature |
| Temperature Control | The furnace enriched up to 20 times |
| Lamp holder | ≤ 8 lamps automatic turret, automatic alignment |
| Lamp power supply mode | Pulsed power supply |
| Optical System | Large 1800 /mm grating ruling, full closed optical system |
| Atomization Chamber | Polymer explosion-proof spray chamber |
| Characteristics Volume | 0.4 × 10-12g (Cd) |
| Detection Limit | 0.4 × 10-12g (Cd) |
| Detection Limit (Cu) | 0.002 μg/mL |
| Burner | Full titanium combustion head, 50 mm or 100 mm general combustion head |
| Nebulizer | Atomizer efficient glass atomizer, can also be customized |
| Precision | RSD ≤ 0.5 |
| Ignition Type | Microcomputer control, automatic ignition |
| Safety measures | Graphite tube damage, water flow Air pressure and other alarm temperature overheating protection |
| Gas Control | Automatic gas control system |
| Cooling Water | Can choose cooling water circulation system |
| Power supply | 110 / 220 V (+5 % to -10 %), 60 / 50 Hz; 5000 VA |
Broad Wavelength Range
High-Resolution Monochromator
Vertical Heating Mode
Wide Temperature Range
High-Sensitivity Detector
Ultra-Low Detection Limits
Automatic Gas Control
Robust Spray Chamber
Durable Burner Head
Comprehensive Safety Alarm System
Flexible Cooling Options
PMT Detector for High Sensitivity
Explosion-Proof Polymer Spray Chamber
Our Atomic Absorption Spectrophotometer LAAS-A23 is ideally suited for ultra-trace metal analysis in environmental monitoring, ensuring compliance by detecting heavy metals like lead and cadmium in water and soil at parts-per-billion levels. Furthermore, its high precision and sensitivity make it an indispensable tool for clinical and biological research, analyzing metal concentrations in tissues and bodily fluids.
Download catalog for
Atomic Absorption Spectrophotometer LAAS-A23 Catalog
Available Range :
Atomic Absorption Spectrophotometer LAAS-A21 : 180 – 900 nm Atomic Absorption Spectrophotometer LAAS-A23 : 185 to 900 nm Atomic Absorption Spectrophotometer LAAS-A20 : 190 to 900 nm Flame Atomic Absorption Spectrophotometer LAAS-A15 : 190 to 900nm Atomic Absorption Spectrophotometer LAAS-A24 : 190nm to 900nm Atomic Absorption Spectrophotometer LAAS-A30 : 3600 L/mm: 190 nm - 500 nmLabtron Atomic Absorption Spectrophotometers offer precise and efficient trace element analysis with adaptable atomization technologies and high-precision optical systems. These feature a titanium combustion head, polymer explosion-proof spray chamber with enhanced safety features and durability. We offer versatile operation modes, including flame, graphite furnace, and hydride generation systems, these meet diverse analytical needs. Our Spectrophotometers boast powerful software and user-friendly design for consistent, reliable results and seamless data management.








Our LAAS-A23 microcomputer-controlled system ensures great efficiency and accuracy in sample analysis by providing automatic ignition mode, vertical heating mode in the graphite furnace analytical system, and a full titanium ignition head.
Our LAAS-A23 Atomic Absorption Spectrophotometer is a flexible and essential instrument for metal analysis in a variety of fluid samples, with broad applications in industries like food, petroleum, chemicals, pharmaceuticals, etc.
Labtron’s Atomic Absorption Spectrophotometer uses a deuterium lamp for background correction to reduce molecular and spectral interference. It automatically aligns the source and adjusts timing to minimize non-metallic absorption. This ensures accurate results in complex or turbid samples. The correction function enhances reliability for trace-level metal analysis.
An analytical tool called an Atomic Absorption Spectrophotometer (AAS) uses the light that each element's atom absorbs to determine the concentration of that element in a sample.
The basis of spectrophotometry is the light uptake by unbound atoms in a gaseous state. An excited state is created when atoms in the ground state absorb light energy at particular wavelengths. Analyte content in the sample can be calculated by determining the amount of light consumed.
The components include an atomizer (commonly used atomizers are Flame atomizers and Electro thermal atomizers), a Radiation source, and a spectrophotometer.
The hollow cathode lamp in atomic absorption spectrophotometer emits distinctive light at particular wavelengths that match the target analyte. This guarantees that the analyte atoms are excited selectively, resulting in exact and reliable readings.
Labtron’s Atomic Absorption Spectrophotometers boast flexible atomization technologies, accurate optical systems, a titanium combustion head, and a polymer explosion-proof spray chamber. These elements guarantee accurate and effective trace element analysis, along with improved safety and longevity.