
Automatic Bomb Calorimeter LABC-B10 is capable of holding a bomb volume of 250 ml and delivers quick results within 10 minutes. It features a fully automatic bomb raising and lowering system. The heating system enables faster heat transfer in the oxygen bomb, reducing the test period. Features include analysis, statistics reporting, and system monitoring. Our bomb calorimeter complies with international standards ASTM D5865 and ISO 1928.
Bomb Volume | 250 ml |
Analysis Time | < 8 min full test process: <10 min |
Bomb Washing | Manual |
Maximum Bomb Pressure | 20 MPa |
Bomb Identity | Yes |
Calorimeter Type | Isoperibol |
Oxygen Filling | Fully Automatic Oxygen Filling & Releasing |
Bomb Raising | Fully Automatic Bomb Raising & Lowering |
No. of Tests | 6/hour |
Temperature Resolution | 0.0001 K |
Precision (RSD) | ≤ 0.01 % |
Heat Capacity Stability | ≤ 0.25 % within three months |
Gas Requirement | 99.5 % oxygen |
Water Requirements | Distilled water |
Energy Measurement Range | 0 to 50000 J |
Bucket Filling | Automatic |
Stirring Method | Propeller |
Safety Function | Self-protection and self-diagnostic functions |
Reproducibility | 0.10 % (analysis of 1 g of benzoic acid) |
Temperature Increase | 2°C (average) |
Temperature Measurement | PT1000 (temperature probe) |
Working Temperatures | ≤ 32°C |
Cooling Type | Refrigerating device |
Network | Yes |
Advance Calculations | Yes |
Maximum Power | 0.6 kW |
Power Supply | 220 V ±, 15 to 10 %, 50/60 Hz |
Water Tank Dimension | 390 × 550 × 440 mm |
Main Body Dimension | 440 × 550 × 460 mm |
Weight | 50 kg |
Our automatic bomb calorimeter is used in the determination of the calorific value of solid and liquid combustibles such as coal, coke, oil, petroleum material, biomass, cement, and others.
Accessory Name | Unit | Quantity |
Main Frame | Piece | 1 |
Refrigerating Device | Unit | 1 |
PC screen | Piece | 1 |
Ignition thread (500 pieces) Box | Box | 20 |
Standard Benzoic Acid (1 gm × 10 pieces) | Bottle | 10 |
Download catalog for
Automatic Bomb Calorimeter LABC-B10 Catalog
Download manual for
Automatic Bomb Calorimeter LABC-B10 Manual
Labtron Automatic Bomb Calorimeter features a semi-conductor water refrigeration system, ensuring efficient and reliable cooling performance. These are equipped with auto-stop and auto-draining joints, providing convenience and safety during operation. Their high-efficiency magnetic churning mechanism enhances mixing performance for precise results. They are integrated electronic measuring cups that allow accurate liquid measurements for improved accuracy. Our automatic bomb calorimeter features helix tube multipoint isothermal technology, ensuring enhanced thermal stability for precise and accurate readings.
Address:Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608