Labtron Automatic Electrolyte Analyzer provide measurement of electrolyte concentration in blood or other biological fluids. They are equipped with specialized electrodes for evaluating specific amount of ions, such as sodium, potassium, and chloride. Their automated pipetting system accurately measures and transfers liquid samples to analysis chamber. They include waste disposal unit that manages removal of used samples and reagents, maintaining clean work environment. Our Automatic Electrolyte Analyzer is essential in diagnosing illnesses, monitoring patients, conducting research, and ensuring safety.
Measuring Parameter : K,Na,Cl
Sample Capacity : 100 µL
Automatic sampling : 25-bit sampling system for option (20 samples, 2 QC, 1 emergency, 1 washing)
Measuring time : 40s
Sample Type : Venous blood
Testing Principle : Dry electrochemistry/Microfluidic method
Measuring Parameters : K+, Na+, Cl-, iCa2+, iMg2+
Minimum Sample Requirement : 100 µL
Sample Type : Plasma, Serum, Whole blood, Urine
Test Parameters : K⁺, Na⁺, Cl ⁻
Sample Volume : 65µL
Test Range : K⁺: 6.00 to 9.00 mmol/L Na⁺: 0.50 to 10.00 mmol/L Cl ⁻: 20.0 to 200.0 mmol/L
Sample Type : Plasma, Serum, Whole blood, Urine
Test Parameters : K⁺, Na⁺, Cl ⁻, Ca²⁺, pH
Sample Volume : 65µL
Test Range : K⁺: 6.00 to 9.00 mmol/L Na⁺: 0.50 to 10.00 mmol/L Cl ⁻: 20.0 to 200.0 mmol/L Ca²⁺: 20.0 to 200.0 mmol/L pH: 0.3 to 5.0 mmol/L
Sample Type : Plasma, Serum, Whole blood, Urine, CSF
Test Parameters : K⁺, Na⁺, Cl ⁻, TCO₂
Sample Volume : 80µL
Test Range : K⁺: 0.5 to 15.0 mmol/L Na⁺: 20.0 to 200.0 mmol/L Cl ⁻: 20.0 to 200.0 mmol/L TCO₂: 6.0 TO 50.0 mmol/L
Sample Type : Plasma, Serum, Whole blood, Urine, CSF
Test Parameters : K⁺, Na⁺, Cl ⁻, Ca²⁺, pH, TCO₂
Sample Volume : 80µL
Test Range : K⁺: 0.5 to 15.0 mmol/L Na⁺: 20.0 to 200.0 mmol/L Cl ⁻: 20.0 to 200.0 mmol/L Ca²⁺: 0.1 to 5.0 mmol/L pH: 6.0 to 9.0 TCO₂: 6.0 TO 50.0 mmol/L
Sample Type : Plasma, Serum, Whole blood, Urine, CSF
Test Parameters : K⁺, Na⁺, Cl ⁻, Ca²⁺, Li⁺, pH, TCO₂
Sample Volume : 80µL
Test Range : K⁺: 0.5 to 15.0 mmol/L Na⁺: 20.0 to 200.0 mmol/L Cl ⁻: 20.0 to 200.0 mmol/L Ca²⁺: 0.1 to 5.0 mmol/L Li⁺: 0.0 to 3.0 mmol/L pH: 6.0 to 9.0 TCO₂: 6.0 TO 50.0 mmol/L
Sample Type : Plasma, Serum, Whole blood, Urine, CSF
Test Parameters : K⁺, Na⁺, Cl ⁻
Sample Volume : 80µL
Test Range : K⁺: 0.5 to 15.0 mmol/L Na⁺: 20.0 to 200.0 mmol/L Cl ⁻: 20.0 to 200.0 mmol/L
Sample Type : Plasma, Serum, Whole blood, Urine, CSF
Test Parameters : K⁺, Na⁺, Cl ⁻, Li⁺
Sample Volume : 80µL
Test Range : K⁺: 0.5 to 15.0 mmol/L Na⁺: 20.0 to 200.0 mmol/L Cl ⁻: 20.0 to 200.0 mmol/L Li⁺: 0.0 to 3.0 mmol/L
Sample Type : Plasma, Serum, Whole blood, Urine, CSF
Test Parameters : K⁺, Na⁺, Cl ⁻, Ca²⁺, pH
Sample Volume : 80µL
Test Range : K⁺: 0.5 to 15.0 mmol/L Na⁺: 20.0 to 200.0 mmol/L Cl ⁻: 20.0 to 200.0 mmol/L Ca²⁺: 0.1 to 5.0 mmol/L pH: 6.0 to 9.0
Sample Type : Plasma, Serum, Whole blood, Urine, CSF
Test Parameters : K⁺, Na⁺, Cl ⁻, Ca²⁺, Li⁺, pH
Sample Volume : 80µL
Test Range : K⁺: 0.5 to 15.0 mmol/L Na⁺: 20.0 to 200.0 mmol/L Cl ⁻: 20.0 to 200.0 mmol/L Ca²⁺: 0.1 to 5.0 mmol/L Li⁺: 0.0 to 3.0 mmol/L pH: 6.0 to 9.0
Sample Type : Plasma, Serum, Whole blood, Urine, CSF
Test Parameters : K⁺, Na⁺, Cl ⁻, Li⁺, TCO₂
Sample Volume : 80µL
Test Range : K⁺: 0.5 to 15.0 mmol/L Na⁺: 20.0 to 200.0 mmol/L Cl ⁻: 20.0 to 200.0 mmol/L Li⁺: 0.0 to 3.0 mmol/L TCO₂: 6.0 TO 50.0 mmol/L