Labtron Biochemistry analyzer are designed to analyze a wide range of test samples. Includes blood, plasma, serum, urine and more. They provide a broader test spectrum. Our analyzer are capable of performing multiple tests simultaneously. These analyzer optimize workflows and save valuable time. We offer both automatic and semi-automatic models for clinical laboratories and medical research. Our biochemistry analyzer are essential for diagnosing diseases and advancing our understanding of biochemical processes.
Sample Volume: 1 to 100 µl , 0.1 µl / step
Reagent Position: 2 × 40
Reagent Volume R1: 1 to 400 µl , 1 µl / step
Reagent Volume R2: 1 to 400 µl , 1 µl / step
Detection Speed: 100 tests per hour
Wavelength: 9 wavelengths, 340nm to 700nm
Sample Size: 2 to 50μL, 0.1μL increments
Absorbance Range: 0 to 4.8 Abs
Sample Type: Anticoagulant whole blood, serum and plasma
Sample Volume: 90-120 μl
Testing Time: 12 minutes / sample
Bar Code: QR code
Absorbance Range: 0 to 3.0 Abs
Aspiration Volume: 100 to 5000 µl
Wavelengths: 340 nm, 380 nm, 405 nm, 505 nm, 546 nm, 578 nm, 620 nm and 1 free position
Principle: Colorimetery, turbimetry
Absorbency Range: -0.3 to 3.0 abs
Resolution: 0.001 abs (display), 0.0001 abs (inner calculation)
Temperature Accuracy: ± 0.1°C
Wavelength: 340 nm, 405 nm, 510 nm, 546 nm, 578 nm, 620 nm + 2 free positions
Measuring System: Measuring Range: 0 to 3.0 OD Method: Absorbance, End Point, Fixed Time, Rate, Sample Blank, Multi Standard, Two point Non Linear, and Sample Blank Non Linear Photometric linearity: ±2% (0 to 3.000 OD) Photometric accuracy: ±1% (0 to 3.000 OD) Carry over: ≤1%
Photometric System: Light source: 6 V, 10 W halogen lamp; standby function Filters: 340 nm, 405 nm, 492 nm, 510 nm, 546 nm, 578 nm, 620 nm and 2 more open filter positions (on request) Wavelength Accuracy: ±2 nm
Thermostatic Control: Temperature: 25˚C, 30˚C, 37˚C Precision: ±0.1˚C
Drift:
Measuring System: Measuring Range: 0 to 3.0 OD Method: Absorbance, End Point, Fixed Time, Rate, Sample Blank, Multi Standard, Two point Non Linear, and Sample Blank Non Linear Photometric linearity: ±2% (0 to 3.000 OD) Photometric accuracy: ±1% (0 to 3.000 OD) Carry over: ≤1%
Photometric System: Light source: 6 V, 10 W halogen lamp; standby function Filters: 340 nm, 405 nm, 492 nm, 510 nm, 546 nm, 578 nm, 620 nm and 2 more open filter positions (on request) Wavelength Accuracy: ±2 nm
Thermostatic Control: Temperature: 25˚C, 30˚C, 37˚C Precision: ±0.1˚C
Drift:
Test Mode: Kinetic, Endpoint, Two-point
Wavelengths: 7wavelength: 340, 405, 492,510, 546,578,630 nm
Wavelength Precision: ±2 nm, width ≤ 10nm
Absorbance Range: 0 to 4.500 Abs