A CO2 incubator, also known as a carbon dioxide incubator, is a specialized piece of laboratory equipment used to maintain a controlled environment for the growth and maintenance of cell cultures, microorganisms, and other biological specimens. It is primarily used in biological, medical, and biotechnological research settings where precise environmental conditions are required to support growth. These incubators are equipped with sensors and alarms to monitor and alert users in case of temperature, CO2 concentration, or humidity deviations outside the set parameters, helping to protect valuable samples.
Chamber Volume : 101 L
Temperature Range : Ambient 5 °C to 60 °C
Temperature Accuracy : ± 0.2 at 37 °C
CO2 Range : 0 to 20 %
Chamber Volume : 150 L
Temperature Range : Ambient 5 °C to 60 °C
Temperature Accuracy : ± 0.2 at 37 °C
CO2 Range : 0 to 20 %
Chamber Volume : 324 L
Temperature Range : Ambient 5 °C to 60 °C
Temperature Accuracy : ± 0.2 at 37 °C
CO2 Range : 0 to 20 %
Chamber Volume : 49 L
Temperature Range : Ambient 5 °C to 60 °C
Temperature Accuracy : ± 0.2 at 37 °C
CO2 Range : 0 to 20 %
Heating method : Water Jacketed
Chamber volume : 170 L
CO2 range : 0 to 20 %
CO2 control resolution : ± 0.1% (IR Sensor)
Chamber volume : 240 L
Heating method : Water Jacketed
CO2 control range : 0 to 20%
CO2 control accuracy : ±0.1% (IR sensor)
Chamber Volume : 80 L
Shelves : 2 (pcs)
Heating Method : Air-jacketed, PID Control
Temperature Range : RT + 5 to 50°C
Chamber Volume : 155 L
Shelves : 3 (pcs)
Heating Method : Air-jacketed, PID Control
Temperature Range : RT + 5 to 50°C
Chamber Volume : 233 L
Shelves : 3 (pcs)
Heating Method : Air-jacketed, PID Control
Temperature Range : RT + 5 to 50°C
Chamber Volume : 49 L
Shelves : 2 (pcs)
Heating Method : Air-jacketed, PID Control
Temperature Range : RT + 5 to 50°C
Chamber Volume : 80 L
Shelves : 2 (pcs)
Heating Method : Air-jacketed, PID Control
Temperature Range : RT + 5 to 50°C
Chamber Volume : 150 L
Shelves : 2 (pcs)
Heating Method : Air-jacketed, PID Control
Temperature Range : RT + 5 to 50°C
Chamber Volume : 40 L
Shelves : 2
Heating Method : Air-jacketed
Temperature Range : RT+5 ℃ to 50 ℃
Chamber Volume : 80 L
Shelves : 2
Heating Method : Air-jacketed
Temperature Range : RT+5 ℃ to 50 ℃
Chamber Volume : 155 L
Shelves : 3
Heating Method : Air-jacketed
Temperature Range : RT+5 ℃ to 50 ℃
Chamber Volume : 233 L
Shelves : 3
Heating Method : Air-jacketed
Temperature Range : RT+5 ℃ to 50 ℃
CO2 range : 0-20%
CO2 recovery time : (Return to 5% after opening the door for 30 seconds) ≤3 mins
CO2 control accuracy : ±0.1%
CO2 stability of 5%CO2 : ±0.1%
CO2 range : 0-20%
CO2 recover time : (Return to 5% after opening the door for 30 seconds) ≤3 mins
CO2 control accuracy : ±0.1%
CO2 stability of 5%CO2 : ±0.1%
Capacity : 570 L
Temperature Range : 5 to 40 °C
Ambient Temperature : 5 to 60 °C
Accuracy : 0.1 °C