-86°C Ultra Low Temperature Chest Freezer LCF-D10 is an ultra-low temperature freezer comprised with 50 L of capacity, offers -40 to -86°C of temperature range with direct cooling method and manual defrost mode. Features microprocessor control system and SECOP compressor with EBM fan and mixture gas refrigerant, provides -86°C of cooling performance. Ergonomic design with high quality steel plate with spraying exterior and stainless-steel interior, has two-times foaming technology with 110 mm foaming insulation. Equipped with advanced alarm system and digital display, has delayed start and safe stop interval protection along with keyboard lock and password access.
Cabinet type | Chest |
Capacity | 50 L |
Temperature Range | -40 to -86°C |
Ambient Temperature | 16 to 32°C |
Cooling Performance | -86°C |
Cooling Method | Direct Cooling |
Defrost Mode | Manual |
Refrigerant | Mixture Gas |
Climate Class | N |
Controller | Microprocessor |
Display | Digital Display |
Compressor | 1 pc. |
Alarm System | High/Low temperature, High ambient temperature, Power failure, Low battery, Sensor failure, Condenser overheating alarm, Built-in datalogger USB failure, Main board communication error |
External Material | High Quality Steel Plates with Spraying |
Internal Material | Stainless-steel |
Insulation | 110 mm |
Casters | 4 |
Door Lock with Key | Yes |
Access Port | 1 pc. Φ25 mm |
Data Logging/Interval/Recording Time | USB/Record every 10 minute / 2 years |
Backup Battery | Yes |
Protection Function | Delayed start and safe stop interval protection |
Power Supply | 220 to 240 V, 50 Hz |
Rated Current | 5.3 A |
Internal Dimension (W×D×H) | 430×305×425 mm |
External Dimension (W×D×H) | 677×606×1081 mm |
Packaging Dimension (W×D×H) | 788×720×1283 mm |
Net Weight | 74 kg |
Gross Weight | 123 kg |
-86°C Ultra Low Temperature Chest Freezer is used across hospitals, health and epidemic prevention system, scientific research institutes, biological engineering, laboratory in colleges and universities, military industrial enterprises, etc.
RS485
Remote alarm contact
Chart Recorder
CO2 Backup System
Available Range :
Cabinet type : Chest Cabinet Type : Chest Cabinet Type : Chest Cabinet Type : Chest Cabinet Type : Chest Cabinet Type : ChestRelated Models :
Model | Cabinet type | Capacity | Temperature Range | Ambient Temperature | Cooling Performance | Cooling Method | Defrost Mode | Refrigerant | Climate Class | Controller | Display | Compressor | Alarm System | External Material | Internal Material | Insulation | Casters | Door Lock with Key | Access Port | Data Logging/Interval/Recording Time | Backup Battery | Protection Function | Power Supply | Rated Current | Internal Dimension (W×D×H) | External Dimension (W×D×H) | Packaging Dimension (W×D×H) | Net Weight | Gross Weight |
LCF-D10 | Chest | 50 L | -40 to -86°C | 16 to 32°C | -86°C | Direct Cooling | Manual | Mixture Gas | N | Microprocessor | Digital Display | 1 pc. | High/Low temperature, High ambient temperature, Power failure, Low battery, Sensor failure, Condenser overheating alarm, Built-in datalogger USB failure, Main board communication error | High Quality Steel Plates with Spraying | Stainless-steel | 110 mm | 4 | Yes | 1 pc. Φ25 mm | USB/Record every 10 minute / 2 years | Yes | Delayed start and safe stop interval protection | 220 to 240 V, 50 Hz | 5.3 A | 430×305×425 mm | 677×606×1081 mm | 788×720×1283 mm | 74 kg | 123 kg |
LCF-D20 | - | 138 L | -40 to -86°C | 16 to 32°C | -86°C | Direct Cooling | Manual | Mixture Gas | N | Microprocessor | Digital Display | 1 pc | High/Low temperature, High ambient temperature, Power failure , Low battery, Sensor failure, Condenser overheating alarm, Built-in datalogger USB failure, Main board communication error | Steel plates with Spraying | Stainless-steel | 152 mm | 4 | Yes | 1 pc Φ40 mm | USB/Record every 10 minute / 2 years | Yes | Delayed start and safe stop interval protection, keyboard lock and password protection | 220 to 240 V, 50 Hz | 5.78 A | 490×470×580 mm | 1320×890×1030 mm | 1470×990×1241 mm | 200 kg | 231 kg |
LCF-D21 | - | 328 L | -40 to -86°C | 16 to 32°C | -86°C | Direct Cooling | Manual | Mixture Gas | N | Microprocessor | Digital Display | 1 pc | High/Low temperature, High ambient temperature, Power failure , Low battery, Sensor failure, Condenser overheating alarm, Built-in datalogger USB failure, Main board communication error | Steel plates with Spraying | Stainless-steel | 152 mm | 6 | Yes | 1 pc Φ40 mm | USB/Record every 10 minute / 2 years | Yes | Delayed start and safe stop interval protection, keyboard lock and password protection | 220 to 240 V, 50 Hz | 5.6 A | 1200×470×570 mm | 2030×890×1020 mm | 2193×1003×1256 mm | 280 kg | 328 kg |
LCF-D22 | - | 668 L | -40 to -86°C | 16 to 32°C | -86°C | Direct Cooling | Manual | Mixture Gas | N | Microprocessor | Digital Display | 2 pcs | High/Low temperature, High ambient temperature, Power failure , Low battery, Sensor failure, Condenser overheating alarm, Built-in datalogger USB failure, Main board communication error | Steel plates with Spraying | Stainless-steel | 130 mm | 6 | Yes | 1 pc Φ40 mm | USB/Record every 10 minute / 2 years | Yes | Delayed start and safe stop interval protection, keyboard lock and password protection | 220 to 240 V, 50 Hz | 9.5 A | 1200×815×610 mm | 2033×1190×1037 mm | 2145×1305×1234 mm | 352 kg | 398 kg |
LCF-D30 | - | 258 L | -40°C to -86°C | - | -86°C | Direct cooling | Manual | CFC free | N | Microprocessor | LED | Single | High/low temperature, Power failure, Remote alarm contact, Sensor error | Powder coated steel | SUS304 | PU forming | 6 | Yes | - | - | - | - | 220 to 240 V/110 V, 50/60 Hz | - | 780×500×660 mm | 1510×885×1095 mm | 1570×945×1230 mm | 220 kg | 240 kg |
LCF-D31 | - | 458 L | -40°C to -86°C | - | -86°C | Direct cooling | Manual | CFC free | N | Microprocessor | LED | Single | High/low temperature, Power failure, Remote alarm contact, Sensor error | Powder coated steel | SUS304 | PU forming | 8 | Yes | - | - | - | - | 220 to 240 V/110 V, 50/60 Hz | - | 1330×500×600 mm | 2110×885×1095 mm | 2170×945×1230 mm | 240 kg | 270 kg |
LCF-D14 | - | 458 L | -60°C to -86°C | - | -86°C | Direct cooling | Manual | CFC free | N | Microprocessor | LED | Single | High/low temperature, Power failure and Sensor error | Powder coated steel | SUS304 | PU forming | 8 Universal lockable casters | Yes | - | - | - | - | 220 to 240 V/110 V, 50/60 Hz | - | 1330×500×600 mm | 2110×885×1095 mm | 2170×945×1230 mm | 240 kg | 270 kg |