-86 °C Ultra Low Temperature Upright Freezer LUF-D20 is an upright type freezer comes with 100 L capacity and offers temperature range -40 to -86˚C and -86˚C cooling performance. Features with microprocessor controlled system with interior digital temperature display to show various parameters simultaneously. Designed with direct cooling system and manual defrost mode, equipped with eco- friendly refrigerant Mixture gas, Built-in high-precision microcomputer temperature control system and platinum resistor temperature sensors. It offers high or low temperature alarm, Door open alarm and Keyboard lock, password protection function to prevent arbitrary adjustment of operating parameters.
Cabinet type | Upright |
Capacity | 100 L |
Temperature range | -40 to -86˚C |
Ambient temperature | 16 to 32˚C |
Cooling performance | -86˚C |
Refrigerant | Mixture gas |
Defrost Mode | Manual |
Cooling method | Direct cooling |
Controller | Microprocessor |
Display | Digital display |
Climate class | N |
Insulation thickness | 90, R:115 mm |
Compressor | 1 pcs |
Alarm system | High and low temperature, high ambient temperature |
External material | Steel plates with spraying |
Inner material | Galvanized steel sheet |
Shelves | 1 (stainless steel) |
Door look with key | Yes |
External Lock | Yes |
Access Port | 1pcs. Φ 25 mm |
Casters | 4 |
Data Logging / Interval/ Recording Time | Printer/Record every 20 minute / 7 days |
Electrical | Power failure, Low battery |
System | Sensor error, Main board communication error ,System failure, Condenser cooling failure, Door ajar, Samples out of date |
Backup Battery | Yes |
Rated power | 950 W |
Input power | 1100 W |
Rated current | 5 A |
Power consumption | 9.2 KWh/24h |
Power supply | 230 ±10% V /50 Hz |
Internal dimension | 450 × 439 × 514 mm |
External dimension | 1066 × 742 × 820 mm |
Package size | 1200 × 863 × 991 mm |
Net weight | 145 kg |
Gross weight | 176 kg |
Upright Freezers is used in scientific research, cryogenic test on special materials, blood plasma cryopreservation, low temperature resistance test on biological materials, vaccines, biological products and military products, etc. and Suitable for use in research institutions, the electronic industry, the chemical industry, hospitals, the health & disease prevention system, laboratories in colleges & universities, military enterprises, etc.
Accessories no. | Name |
---|---|
1 | Chart recorder |
2 | CO2 backup system |
Available Range :
Cabinet type : Upright Cabinet type : Upright Cabinet type : Upright Cabinet type : Upright Cabinet type : Upright Cabinet type : UprightRelated Models :
Model | Cabinet type | Capacity | Temperature range | Ambient temperature | Cooling performance | Refrigerant | Defrost Mode | Cooling method | Controller | Display | Climate class | Insulation thickness | Compressor | Alarm system | External material | Inner material | Shelves | Door look with key | External Lock | Access Port | Casters | Data Logging / Interval/ Recording Time | Electrical | System | Backup Battery | Rated power | Input power | Rated current | Power consumption | Power supply | Internal dimension | External dimension | Package size | Net weight | Gross weight |
LUF-C10 | Upright | 398 L | -40 to -86˚C | 16 to 32˚C | -86˚C | Mixture gas | Manual | Direct cooling | Microprocessor | Touch screen | N | 130 mm | 1 pcs | High and low temperature, high ambient temperature | High quality steel plates with spraying | Galvanized steel sheet | 3 (stainless steel) | Yes | Yes | 2 pcs. Φ 25 mm | 4 +(2 leveling feet) | USB/Record every 1 minute / 365 days | Power failure, Low battery | Sensor error, Main board communication error, Built-in data logger USB failure, Condenser cooling failure, Door ajar, Samples out of date, System failure | Yes | 950 W | 980 W | 5 A | 11 KWh/24h | 230 ±10% V /50 Hz | 450 × 696 × 1266 mm | 785 × 1041 × 1947 mm | 890 × 1165 × 2145 mm | 237 kg | 272 kg |
LUF-C11 | Upright | 528 L | -40 to -86˚C | 16 to 32˚C | -86˚C | Mixture gas | Manual | Direct cooling | Microprocessor | Touch screen | N | 130 mm | 1 pcs | High and low temperature, high ambient temperature | High quality steel plates with spraying | Galvanized steel sheet | 3 (stainless steel) | Yes | Yes | 2 pcs. Φ 25 mm | 4 +(2 leveling feet) | USB/Record every 1 minute / 365 days | Power failure, Low battery | Sensor error, Main board communication error, Built-in data logger USB failure, Condenser cooling failure, Door ajar, Samples out of date, System failure | Yes | 1265 W | 1445 W | 6.57 A | 12.82 KWh/24h | 230 ±10% V /50 Hz | 585 × 696 × 1266 mm | 930 × 1041 × 1947 mm | 1035 × 1165 × 2145 mm | 286 kg | 319 kg |
LUF-C12 | Upright | 678 L | -40 to -86˚C | 16 to 32˚C | -86˚C | Mixture gas | Manual | Direct cooling | Microprocessor | Touch screen | N | 130 mm | 1 pcs | High and low temperature, high ambient temperature | High quality steel plates with spraying | Galvanized steel sheet | 3 (stainless steel) | Yes | Yes | 3 pcs. Φ 25 mm | 4 +(2 leveling feet) | USB/Record every 1 minute / 365 days | Power failure, Low battery | Sensor error, Main board communication error, Built-in data logger USB failure, Condenser cooling failure, Door ajar, Samples out of date, System failure | Yes | 1680 W | 2000 W | 9.1 A | 15 KWh/24h | 230 ±10% V /50 Hz | 750 × 696 × 1286 mm | 1090 × 1025 × 1965 mm | 1203 × 1155 × 2171 mm | 330 kg | 382 kg |
LUF-C13 | Upright | 778 L | -40 to -86˚C | 16 to 32˚C | -86˚C | Mixture gas | Manual | Direct cooling | Microprocessor | Touch screen | N | 130 mm | 2 pcs | High and low temperature, high ambient temperature | High quality steel plates with spraying | Galvanized steel sheet | 3 (stainless steel) | Yes | Yes | 3 pcs. Φ 25 mm | 4 +(2 leveling feet) | USB/Record every 1 minute / 365 days | Power failure | Sensor error, Built-in data logger USB failure , Main board communication error , Condenser cooling failure, Door ajar, Samples out of date, System failure | Yes | 1750 W | 2050 W | 9. 31 A | 15 KWh/24h | 230 ±10% V /50 Hz | 865 × 696 × 1286 mm | 1205 × 1025 × 1955 mm | 1203 × 1155 × 2171 mm | 365 kg | 408 kg |
LUF-C14 | Upright | 858 L | -40 to -86˚C | 16 to 32˚C | -86˚C | Mixture gas | Manual | Direct cooling | Microprocessor | Touch screen | N | 130 mm | 2 pcs | High and low temperature, high ambient temperature | High quality steel plates with spraying | Galvanized steel sheet | 3 (stainless steel) | Yes | Yes | 3 pcs. Φ 25 mm | 4 +(2 leveling feet) | USB/Record every 1 minute / 365 days | Power failure, Low battery | Sensor error, Built-in data logger USB failure ,Main board communication error , System failure, Condenser cooling failure ,Door ajar, Samples out of date | Yes | 1900 W | 2380 W | 10.86 A | 16.5 KWh/24h | 230 ±10% V /50 Hz | 877 × 696 × 1378 mm | 1217 × 1025 × 2005 mm | 1330 × 1155 × 2176 mm | 390 kg | 431 kg |
LUF-C15 | Upright | 1008 L | -40 to -86˚C | 16 to 32˚C | -86˚C | HC Mixture gas | Manual | Direct cooling | Microprocessor | 7-inch LED Touch screen | N | 130 mm | 2 pcs | High and low temperature, high ambient temperature, Power failure, Sensor error, Main board communication error, Built-in datalogger USB failure, Condenser overheating failure, Door ajar, System failure | High quality steel plates with spraying | Galvanized steel sheet | 3 (stainless steel) | Yes | Yes | 3 pcs. Φ 25 mm | 4 +(2 leveling feet) | USB/Record every 1 minute / 365 days | - | - | Yes | - | - | - | - | 220 to 230 V /50 Hz | - | - | - | 430 kg | 559 kg |
LUF-C20 | Upright | 100 L | -40 to -86˚C | 16 to 32˚C | -86˚C | Mixture gas | Manual | Direct cooling | Microprocessor | Digital display | N | 90 mm, R:115 mm | 1 pc. | High and low temperature, high ambient temperature, Power failure, Low battery, Sensor error, Main board communication error, System failure, Condenser cooling failure, Door ajar, Built-in data logger USB failure | Steel plates with spraying | Stainless steel | 1 (stainless steel) | Yes | Yes | 1pcs. Φ 25 mm | 4 | USB/Record every 10 minute / 2 years | - | - | Yes | 950 W | 1100 W | 4.75 A | 9.2 kWh/24h | 220 to 240 V /50 Hz | 450 × 439 × 514 mm | 1074 × 751 × 820 mm | 1200 × 863 × 991 mm | 145 kg | 227 kg |
LUF-C30 | Upright | 218 L | -40 to -86˚C | 16 to 32˚C | -86˚C | Mixture gas | Manual | Direct cooling | Microprocessor | Digital display | N | 155 mm | 1 pc. | High and low temperature, high ambient temperature, Power failure, Low battery, Sensor failure, Condenser overheating, Door ajar, Built-in datalogger USB failure, Main board communication error | Steel plates with spraying | Galvanized steel sheet | 1 (stainless steel) | Yes | Yes | 1pcs | 4 | USB/Record every 10 minute / 2 years | - | - | Yes | 1200 W | 1300 W | 5.96 A | 8.63 kWh/24h | 220 to 240 V /50 Hz | 470 × 580 × 767 mm | 862 × 976 × 1555 mm | 983 × 1073 × 1741 mm | 218 kg | 272 kg |
LUF-D20 | Upright | 100 L | -40 to -86˚C | 16 to 32˚C | -86˚C | Mixture gas | Manual | Direct cooling | Microprocessor | Digital display | N | 90, R:115 mm | 1 pcs | High and low temperature, high ambient temperature | Steel plates with spraying | Galvanized steel sheet | 1 (stainless steel) | Yes | Yes | 1pcs. Φ 25 mm | 4 | Printer/Record every 20 minute / 7 days | Power failure, Low battery | Sensor error, Main board communication error ,System failure, Condenser cooling failure, Door ajar, Samples out of date | Yes | 950 W | 1100 W | 5 A | 9.2 KWh/24h | 230 ±10% V /50 Hz | 450 × 439 × 514 mm | 1066 × 742 × 820 mm | 1200 × 863 × 991 mm | 145 kg | 176 kg |
LUF-D21 | Upright | 218 L | -40 to -86˚C | 16 to 32˚C | -86˚C | Mixture gas | Manual | Direct cooling | Microprocessor | Digital display | N | 155 mm | 1 pcs | High and low temperature, high ambient temperature | Steel plates with spraying | Galvanized steel sheet | 1 (stainless steel) | Yes | Yes | 1pcs | 4 | Printer/Record every 20 minute / 7 days | Power failure, Low battery | Sensor error, System failure, Condenser cooling failure, Door ajar | Yes | 1200 W | 1300 W | 5.96 A | 8.63 KWh/24h | 230 ±10% V /50 Hz | 450 × 580 × 767 mm | 840 × 985 × 1568 mm | 1098 × 988 × 1761 mm | 218 kg | 235 kg |
LUF-D22 | Upright | 398 L | -40 to -86˚C | 16 to 32˚C | -86˚C | Mixture gas | Manual | Direct cooling | Microprocessor | Touch screen | N | 130 mm | 1 pcs | High and low temperature, high ambient temperature | High quality steel plates with spraying | Galvanized steel sheet | 3 (stainless steel) | Yes | Yes | 2 pcs. Φ 25 mm | 4 +(2 leveling feet) | USB/Record every 1 minute / 365 days | Power failure, Low battery | Sensor error, Main board communication error, Built-in data logger USB failure, Condenser cooling failure, Door ajar, Samples out of date, System failure | Yes | 950 W | 980 W | 5 A | 11 KWh/24h | 230 ±10% V /50 Hz | 450 × 696 × 1266 mm | 785 × 1041 × 1947 mm | 890 × 1165 × 2145 mm | 237 kg | 272 kg |
LUF-D23 | Upright | 528 L | -40 to -86˚C | 16 to 32˚C | -86˚C | Mixture gas | Manual | Direct cooling | Microprocessor | Touch screen | N | 130 mm | 1 pcs | High and low temperature, high ambient temperature | High quality steel plates with spraying | Galvanized steel sheet | 3 (stainless steel) | Yes | Yes | 2 pcs. Φ 25 mm | 4 +(2 leveling feet) | USB/Record every 1 minute / 365 days | Power failure, Low battery | Sensor error, Main board communication error, Built-in data logger USB failure, Condenser cooling failure, Door ajar, Samples out of date, System failure | Yes | 1265 W | 1445 W | 6.57 A | 12.82 KWh/24h | 230 ±10% V /50 Hz | 585 × 696 × 1266 mm | 930 × 1041 × 1947 mm | 1035 × 1165 × 2145 mm | 286 kg | 319 kg |
LUF-D24 | Upright | 678 L | -40 to -86˚C | 16 to 32˚C | -86˚C | Mixture gas | Manual | Direct cooling | Microprocessor | Touch screen | N | 130 mm | 1 pcs | High and low temperature, high ambient temperature | High quality steel plates with spraying | Galvanized steel sheet | 3 (stainless steel) | Yes | Yes | 3 pcs. Φ 25 mm | 4 +(2 leveling feet) | USB/Record every 1 minute / 365 days | Power failure, Low battery | Sensor error, Main board communication error, Built-in data logger USB failure, Condenser cooling failure, Door ajar, Samples out of date, System failure | Yes | 1680 W | 2000 W | 9.1 A | 15 KWh/24h | 230 ±10% V /50 Hz | 750 × 696 × 1286 mm | 1090 × 1025 × 1965 mm | 1203 × 1155 × 2171 mm | 330 kg | 382 kg |
LUF-D25 | Upright | 778 L | -40 to -86˚C | 16 to 32˚C | -86˚C | Mixture gas | Manual | Direct cooling | Microprocessor | Touch screen | N | 130 mm | 2 pcs | High and low temperature, high ambient temperature | High quality steel plates with spraying | Galvanized steel sheet | 3 (stainless steel) | Yes | Yes | 3 pcs. Φ 25 mm | 4 +(2 leveling feet) | USB/Record every 1 minute / 365 days | Power failure | Sensor error, Built-in data logger USB failure , Main board communication error , Condenser cooling failure, Door ajar, Samples out of date, System failure | Yes | 1750 W | 2050 W | 9. 31 A | 15 KWh/24h | 230 ±10% V /50 Hz | 865 × 696 × 1286 mm | 1205 × 1025 × 1955 mm | 1203 × 1155 × 2171 mm | 365 kg | 408 kg |
LUF-D26 | Upright | 858 L | -40 to -86˚C | 16 to 32˚C | -86˚C | Mixture gas | Manual | Direct cooling | Microprocessor | Touch screen | N | 130 mm | 2 pcs | High and low temperature, high ambient temperature | High quality steel plates with spraying | Galvanized steel sheet | 3 (stainless steel) | Yes | Yes | 3 pcs. Φ 25 mm | 4 +(2 leveling feet) | USB/Record every 1 minute / 365 days | Power failure, Low battery | Sensor error, Built-in data logger USB failure ,Main board communication error , System failure, Condenser cooling failure ,Door ajar, Samples out of date | Yes | 1900 W | 2380 W | 10.86 A | 16.5 KWh/24h | 230 ±10% V /50 Hz | 877 × 696 × 1378 mm | 1217 × 1025 × 2005 mm | 1330 × 1155 × 2176 mm | 390 kg | 431 kg |