Dry bath incubator LDBI-A21 is a safe and reliable equipment that uses high purity aluminum as a heat conducting medium. It is fitted with a microprocessor controlled system along with digital temperature display, sloped control panel, user calibration feature and in-built over temperature protection device.
Temperature range | RT. 5°C ~ 100°C |
Temperature setting range | 0 °C - 100 °C |
Temperature accuracy | ≤ ± 0.3 °C |
Temperature uniformity | ≤ ± 0.3 °C |
Heating time | ≤ 12 min (25°C ~ 100°C) |
Display accuracy | 0.1 °C |
Time range | 1 min - 99 hr. 59 min |
Auto running | Yes |
Auto heating | Yes |
Auto resume to run | Yes |
Multi points running | Yes (Max. 5 points) |
Multi points running circularly | Yes (Max. 99 times) |
Voltage | AC 24 V / 1.67 A |
Power | 150 W |
Fuse | 250 V / 3A / ɸ5 x 20 |
Dimension (L x W x H) | 260 x 195 x 150 mm |
Net weight | 2.5 kg |
Gross Weight | 2.5 kg |
Dry bath incubator can be used for: DNA amplification, enzyme-substrate reactions, serum coagulation, blood-urea nitrogen determination etc.
Model | Diameter of test tube | Capacity |
DBA-23 | 0.2 ml | 96 |
DBA-24 | 0.5 ml | 54 |
DBA-25 | 1.5 ml | 35 |
DBA-26 | 2.0 ml | 35 |
DBA-27 | 0.5 ml + 1.5 ml | 15 + 20 |
DBA-28 | 0.2 ml (Elisa plate) | 96 |
DBA-29 | 5 ml | 24 |
DBA-30 | 10 ml | 15 |
DBA-31 | 15 ml | 12 |
DBA-32 | 50 ml | 6 |
Model | Temperature range | Temperature control range | Temperature setting range | Temperature accuracy | Temperature uniformity | Temperature stability | Block quantity | Heating time | Cooling time | Display accuracy | Time range | Auto warming | Auto running | Auto heating | Auto resume to run | Multi points running | Multi points running circularly | Voltage | Power | Fuse | Dimension (L x W x H) | Net weight | Gross Weight |
LDBI-A10 | RT. 5°C ~ 160°C | - | - | ± 0.5 °C at 40 °C ; ± 1 °C at 120°C | ± 0.5 °C | - | 1 or 2 | ≤ 15 min (25 °C ~ 160 °C) | - | ± 0.1 °C | 1 min - 99 hr. 59 min | - | - | - | - | - | - | AC 220 V / 110 V (Optional) | 300 W | - | 260 x 220 x 100 mm | 5 kg | 5.5 kg |
LDBI-A11 | RT. 5°C ~ 130°C | - | - | ± 0.5 °C at 40 °C ; ± 1 °C at 120°C | ± 0.5 °C | - | 4 | ≤ 20 min (25 °C ~ 130 °C) | - | 0.1 °C | 1 min - 99 hr. 59 min | - | - | - | - | - | - | 220 V,50 / 60 Hz | 600 W | - | 360 x 220 x 100 mm | 8 kg | 8.0 kg |
LDBI-A20 | RT. 5°C ~ 100°C | - | - | ≤ ± 0.3°C | ≤ ± 0.3 °C | ± 0.3°C | - | ≤ 10 min (25°C ~ 100°C) | - | 0.1 °C | 1 min - 99 hr. | - | - | - | - | - | - | AC 24 V/ 1.67 A | 40 W | - | 260 x 195 x 150 mm | 4.5 kg | 4.5 kg |
LDBI-A21 | RT. 5°C ~ 100°C | - | 0 °C - 100 °C | ≤ ± 0.3 °C | ≤ ± 0.3 °C | - | - | ≤ 12 min (25°C ~ 100°C) | - | 0.1 °C | 1 min - 99 hr. 59 min | - | Yes | Yes | Yes | Yes (Max. 5 points) | Yes (Max. 99 times) | AC 24 V / 1.67 A | 150 W | 250 V / 3A / ɸ5 x 20 | 260 x 195 x 150 mm | 2.5 kg | 2.5 kg |
LDBI-A30 | - | RT. (-30) °C - 100°C | (-10) ℃ - 100 ℃ | ≤ ± 0.3 °C | ≤ ± 0.3 °C | - | - | ≤ 10 min (25°C ~ 100°C) | ≤ 10 min (100°C ~ 25°C) / ≤ 25 min (from room temp. to under it 30°C) | 0.1°C | 1 min - 99 hr. 59 min | Yes | Yes | Yes | Yes | Yes (Max. 5 points) | Yes (Max. 99 times) | AC 110 V - 220 V / 50 - 60 Hz | 150 W | 250 V / 3A / ɸ5 x 20 | 260 x 195 x 150 mm | 4.5 kg | 4.5 kg |
LDBI-B10 | Room temperature +5 to 120 ℃ | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |