Base Number Tester LAAT-A13

Labtron LAAT-A13 is composed of automatic potential titrator and titration device. It is designed according to Industry Standard of Petrochemical and follows ASTM D2896 and ASTM D4739"Test Methods for Base Number of Petroleum Products".

Request Quote
Volumetric analysis Titration condensation: 0.1 N;
Controlling accuracy: ≤ ± 0.02 ml
Automatic acid titration Titration condensation: 0.1 N;
Controlling accuracy: ≤ ± 0.1 pH
Automatic potential control Titration condensation: 0.1 N;
Controlling accuracy: ≤ 10 mV
Ambient temperature 0 ~ 35 ℃
Relative humidity ≤ 85 %
Temperature compensation Manual compensation; 5 ~ 60 ℃
Preset adjustment range of end point pH 1 to 13 or ± 100 ~ 1300 mV
Preset controlling range for titration 1 ~ 3 pH or 100 ~ 300 mV from end point
Power supply AC 220 V ± 10 %, 50 Hz
  • Adopts principle of acid-alkali neutralization Wide measuring range High accuracy Easy operation

It is used to determine and calculate base number of sample based on acid-alkali neutralization principle, perchloric and acid potentiometric titration methods and potential changes to detect end point

Compare Models

Model Graduated flask Conical flask Separatory funnel Volumetric analysis Automatic acid titration Automatic potential control Measurement range Potential measurement range Burette volume Minimum titration volume Burette precision Precision Ambient temperature Relative humidity Temperature compensation Preset adjustment range of end point Preset controlling range for titration Precision of titration tube Test tube Acidometer Full scale Acidometer Accuracy Heating power Total power consumption Power supply Dimension Net weight
LAAT-A10 100 ml,50 ml 100ml 250ml - - - - - - - - - (-10 )°C to 35 °C ≤ 85 % - - - - Φ18 mm x 100 mm 0 ~ 14.00 pH ± 0.01 pH 100 W ~ 1000 W Not more than 1200 W AC 220 V ± 10 %, 50 Hz 570 x 540 x 260 mm -
LAAT-A11 - - - - - - - - - - - - ≤ 35 °C ≤ 85 % - - - Scale division is 0.02 ml - - - - ≤ 1200 W AC 220 V ± 10 %, 50 Hz 830 x 290 x 370 mm -
LAAT-A12 - - - - - - ≥0.05 mg KOH/g 0 to 1800.0 mV 10 mL 0.001 ml ±0.1 %FS Fit or above the relative standards 5℃ to 35℃ Less 80 % - - - - - - - - - AC (220±11)V , 50±1 Hz About 350 × 280 ×178 mm Main unit 14 kg
LAAT-A13 - - - Titration condensation: 0.1 N;
Controlling accuracy: ≤ ± 0.02 ml
Titration condensation: 0.1 N;
Controlling accuracy: ≤ ± 0.1 pH
Titration condensation: 0.1 N;
Controlling accuracy: ≤ 10 mV
- - - - - - 0 ~ 35 ℃ ≤ 85 % Manual compensation; 5 ~ 60 ℃ pH 1 to 13 or ± 100 ~ 1300 mV 1 ~ 3 pH or 100 ~ 300 mV from end point - - - - - - AC 220 V ± 10 %, 50 Hz - -