LCFP-A10 is compact, stand-alone closed cup flash point tester which determines the low temperature operability in diesel fuel, biodiesel, blends and gas oils. It is designed as per “Test Methods for Flash Point of Petroleum Products (Pensky-Martens Closed Cup Methods)” ASTM D93.
Ambient temperature | ≤ 35 °C |
Relative humidity | ≤ 85 % |
Temperature range | 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C |
Aperture of ignition device | 0.8 mm |
Standard oil cup-Inner diameter | 50.7 ~ 50.8 mm |
Standard oil cup- Depth | 55.7 ~ 56.0 mm |
Standard oil cup- Depth of Marked line on the oil cup | 33.9 ~ 34.3 mm |
Standard oil cup-Oil sample cubage | About 70 ml |
Stirring speed | 90 ~ 120 rpm for procedure A; 250 ± 10 rpm for procedure B |
Stirring blade | 8 × 40 mm |
Sample temperature rising rate | 1 ~ 12 °C per minute |
Heating power | 0 ~ 600 W |
Dimension | 420 × 350 × 350 mm |
Total Power Consumption | 600 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
It is suitable to determine closed cup flash point of petroleum products having a flash point higher than 40 °C
Available Range :
Ambient temperature : ≤ 35 °C Ambient temperature : 10 °C ~ 40 °C Ambient temperature : 10 °C ~ 40 ℃Related Models :
Model | Ambient temperature | Relative humidity | Ignition Mode | Temperature range | Aperture of ignition device | Standard oil cup-Inner diameter | Standard oil cup- Depth | Standard oil cup- Depth of Marked line on the oil cup | Standard oil cup-Oil sample cubage | Stirring speed | Stirring blade | Sample temperature rising rate | Measurement Range | Flash Point | Resolution | Repeatability | Reproducibility | Accuracy | Precision | Gas Flame | Heating power | Dimension | Total Power Consumption | Power supply | Net Weight |
LCFP-A10 | ≤ 35 °C | ≤ 85 % | - | 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C | 0.8 mm | 50.7 ~ 50.8 mm | 55.7 ~ 56.0 mm | 33.9 ~ 34.3 mm | About 70 ml | 90 ~ 120 rpm for procedure A; 250 ± 10 rpm for procedure B | 8 × 40 mm | 1 ~ 12 °C per minute | - | - | - | - | - | - | - | - | 0 ~ 600 W | 420 × 350 × 350 mm | 600 W | AC 220 V ± 10 %, 50 Hz | - |
LCFP-A11 | 10 °C ~ 40 °C | ≤ 80 % | - | - | - | - | - | - | - | - | - | - | Ambient Temperature ~ 250 °C | Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C | 0.1 °C | - | - | - | 0.005 | 3 ~ 4 mm | - | 550 × 470 × 500 mm | 350 W | AC 220 V ± 10 %, 50 Hz | - |
LCFP-A13 | 10 °C ~ 40 ℃ | ≤ 80 % | electron igniter / gas flame | Room Temperature ~ 300 ℃ | - | - | - | - | - | - | - | - | Room Temperature ~ 300 ℃ | - | 0.1 ℃ | ≤ 2 ℃ | ≤ 4 ℃ | 0.005 | - | - | - | - | 300 W | AC 220 V ± 10 %, 50 Hz | - |