info@labtron.com +44 2080 043608

Automatic PMCC Flash Point Tester LCFP-A13

LCFP-A13 is designed with RS-323 and 485 computer ports which can calibrate the effect of barometric pressure to the test and calculate the modified value. It modifies system deviation automatically and can simulate and show temperature-time curve. It is designed as per “Test Methods for Flash Point of Petroleum Products (Closed Cup Methods)” ASTM D93.

Request Quote
Ambient temperature 10 °C ~ 40 ℃
Relative humidity ≤ 80 %
Ignition Mode electron igniter / gas flame
Temperature range Room Temperature ~ 300 ℃
Measurement Range Room Temperature ~ 300 ℃
Resolution 0.1 ℃
Repeatability ≤ 2 ℃
Reproducibility ≤ 4 ℃
Accuracy 0.005
Total Power Consumption 300 W
Power supply AC 220 V ± 10 %, 50 Hz
  • Predetermined temperature, sample serial number, atmospheric pressure, test data and other parameters Modifies test data, test time, and other parameters LCD display Electron igniter for flame ignition Effective wind cooling function It can save test data of 100 groups

It is used to determine the flash point of diesel and other fuel types in petrochemical analysis, flavors in food testing, paints in materials testing, and waste removal for environmental analysis

Compare Models

Model Ambient temperature Relative humidity Ignition Mode Temperature range Aperture of ignition device Standard oil cup-Inner diameter Standard oil cup- Depth Standard oil cup- Depth of Marked line on the oil cup Standard oil cup-Oil sample cubage Stirring speed Stirring blade Sample temperature rising rate Measurement Range Flash Point Resolution Repeatability Reproducibility Accuracy Precision Gas Flame Heating power Dimension Total Power Consumption Power supply Net Weight
LCFP-A10 ≤ 35 °C ≤ 85 % - 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C 0.8 mm 50.7 ~ 50.8 mm 55.7 ~ 56.0 mm 33.9 ~ 34.3 mm About 70 ml 90 ~ 120 rpm for procedure A; 250 ± 10 rpm for procedure B 8 × 40 mm 1 ~ 12 °C per minute - - - - - - - - 0 ~ 600 W 420 × 350 × 350 mm 600 W AC 220 V ± 10 %, 50 Hz -
LCFP-A11 10 °C ~ 40 °C ≤ 80 % - - - - - - - - - - Ambient Temperature ~ 250 °C Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C 0.1 °C - - - 0.005 3 ~ 4 mm - 550 × 470 × 500 mm 350 W AC 220 V ± 10 %, 50 Hz -
LCFP-A13 10 °C ~ 40 ℃ ≤ 80 % electron igniter / gas flame Room Temperature ~ 300 ℃ - - - - - - - - Room Temperature ~ 300 ℃ - 0.1 ℃ ≤ 2 ℃ ≤ 4 ℃ 0.005 - - - - 300 W AC 220 V ± 10 %, 50 Hz -

Most Viewed

Customer Enquiry Form

Ask Expert

Address: Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608