Distillation Tester (low temperature single unit) LDT-A17 is a single distillation system with advanced refrigerator compressor. It is devised according to (Test Methods for Distillation Characteristics of Petroleum Products at Barometric Pressure) as per ASTM D86.
Graduated flasks | 100 ml |
Distillation flask | 125 mL |
Ambient temperature | ≤ 30 °C |
Relative humidity | ≤ 85 % |
Temperature controlling range | 0 °C to 60 °C |
Temperature controlling accuracy | ± 0.5 °C |
Thermometer | (-2 )°C to 300 ℃ and (-2) °C to 400 ℃ |
Division value | 1°C |
Scale division | 1 ml |
Inner diameter of electric furnace | φ32 mm, φ38 mm |
Outer diameter of electric furnace | φ50 mm |
Dimension | 720 x 590 x 660 mm |
Heating power system | 1000 W |
Total power consumption | ≤ 2500 W |
Power supply | AC 220 V ± 10 %, 50 Hz |
It is used to determine distillation characteristics of gasoline, aviation gasoline, jet fuels, special boiling point solvent, naphtha, diesel oil, distillate and similar petroleum products.
Model | Graduated flasks | Distillation flask | Ambient temperature | Relative humidity | Temperature controlling range | Temperature controlling accuracy | Thermometer | Division value | Scale division | Inner diameter of electric furnace | Outer diameter of electric furnace | Dimension | Heating power system | Total power consumption | Power supply |
LADA-A10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
LDT-A11 | - | - | -10°C to 35°C | ≤ 85 % | - | - | Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C | - | 0.1 ℃ | - | - | - | 1000 W | ≤ 1100 W | AC 220 V ± 10 %, 50 Hz |
LDT-A15 | 100 ml | 125 ml | ≤ 35 °C | ≤ 85 % | - | ± 0.5 °C | (-2 )°C to 300 ℃ and (-2) °C to 400 ℃ | - | - | φ32 mm, φ38 mm | φ50 mm | 830 x 610 x 870 mm | 1000 W × 2 | ≤ 2500 W | AC 220 V ± 10 %, 50 Hz |
LDT-A16 | 100 ml | 125 ml | ≤ 35 °C | ≤ 85 % | - | ± 0.5 °C | (-2 )°C to 300 ℃ and (-2) °C to 400 ℃ | 1°C | 1 ml | φ32 mm, φ38 mm | φ50 mm | 830 x 610 x 870 mm | 1000 W × 2 | ≤ 5000 W | AC 220 V ± 10 %, 50 Hz |
LDT-A14 | - | 125 mL | Room temperature to 35 °C | ≤ 85 % | - | - | (-2 )°C to 300 ℃ and (-2) °C to 400 ℃ | 1℃ | 1 ml | - | - | 620 × 510 × 620 mm | 1000 W | - | AC 220 V ± 10 %, 50 Hz |
LDT-A10 | 10 ml and 100 ml | - | (-10) °C ~ 35 °C | ≤ 85 % | - | - | 0 °C ~ 360 °C | - | 1 °C | Ф50 mm, Ф30 mm and with a gap | Ф105 mm | 790 x 360 x 710 mm | 1000 W / 220 V | ≤ 1100 W | AC 220 V ± 10 %, 50 Hz |
LDT-A12 | 100 ml | - | - | - | - | - | - | - | - | - | - | 620 x 510 x 620 mm | 1000 W | - | AC 220 V ± 10 %, 50 Hz |
LDT-A17 | 100 ml | 125 mL | ≤ 30 °C | ≤ 85 % | 0 °C to 60 °C | ± 0.5 °C | (-2 )°C to 300 ℃ and (-2) °C to 400 ℃ | 1°C | 1 ml | φ32 mm, φ38 mm | φ50 mm | 720 x 590 x 660 mm | 1000 W | ≤ 2500 W | AC 220 V ± 10 %, 50 Hz |
LDT-A13 | - | - | 5 °C to 35 ℃ | ≤ 85 % | - | ± 1 ℃ | - | - | - | - | - | - | - | - | AC 220 V, 50 Hz |
LDT-A18 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |