Nano spectrophotometer is micro volume UV spectrophotometer which takes measurements at 230 nm, 260 nm, 280 nm. It utilizes CCD detector, Xenon flash lamp as light source which has high stability and long operating life. They are used to detect micro volume quantities of nucleic acids and other concentrated or dilute components is specially designed to analyze the concentration of pure of nucleic acid. The data can be printed with built in printer and can be transferred via SD- RAM card or USB. It requires only minimal amount of sample for accurate measurement.
Wavelength range | 230 nm, 260 nm, 280 nm |
Path length | 1.0 mm, 0.2 mm |
Minimum Sample size | 0.3 - 2.0 µl |
Absorbance range | 0.2 - 75A (10 mm equivalent absorbance) |
Absorbance precision | 0.002 Abs |
Absorbance accuracy | 0.01 |
Light source | Xenon flash lamp |
Measurement time | < 5 s |
Detects nucleic acid up to | 10 - 3750 ng/µL (dsDNA) |
Detects protein up to | 0.5 - 110 mg/mL (BSA) |
Dimension | 240 x 220 x 140 mm |
Weight | 2.35 kg |
The nano spectrophotometer is used in laboratory, food industries, chemistry, microbiology, medicine research and development.
Available Range :
Wavelength range : 200 - 800 nm Wavelength range : 200 - 850 nm Wavelength range : 230 nm, 260 nm, 280 nm Cuvette : No Cuvette : Yes Cuvette : YesRelated Models :
Model | Cuvette | Temperature | PC | Wavelength range | Path length | Wavelength accuracy | Wavelength Resolution | Path length of cuvette | Minimum Sample size | Absorbance range | Precision of wavelength | Absorbance precision | Absorbance accuracy | Light source | Measurement time | Operating Voltage | Sample Pedestal Material | Detector Type | Screen | Software Compatibility | Detects nucleic acid up to | Detects protein up to | Data Output | Operating Power Consumption | Standby Power Consumption | Dimension | Weight |
LNS-A10 | - | - | - | 200 - 800 nm | 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary) | ± 1 nm | ≤ 3 nm (FWHM at Hg 546 nm) | - | 0.5 - 2.0 µl | 0.02 - 90 A (10mm equivalent) | - | 0.003 Abs | 1 % ( 7.332 Abs at 260 nm) | Xenon flash lamp | < 8 s | 24 V DC | Aluminum alloy and Quartz fiber | 3864-element linear silicon CCD array | - | Windows 7, Windows XP | 2 - 4500 ng/µL (dsDNA) | - | - | 20 W | 5 W | 200 x 250 x 166 mm | 2.6 kg |
LNS-A21 | - | - | - | 200 - 850 nm | 1 mm, 2 mm, 5 mm, 10 mm | ± 1 nm | 2 nm (FWHM at Hg 546 nm) | - | 0.3 - 2.0 µl | 0.00 2 ~ 75 A (150, 300 optional, 10mm equivalent absorbance) | - | 0.002 Abs | 1 % (0.76 absorbance at 350 nm) | Xenon flash lamp | < 5 s | - | - | 2048-element linear silicon CCD | - | - | 4 - 3750 ng/µL (7500,15000 optional, dsDNA) | 0.01 - 100 mg/mL (200, 400 optional, BSA) | - | - | - | 240 x 210 x 110 mm | 1.92 kg |
LNS-B11 | - | - | - | 230 nm, 260 nm, 280 nm | 1.0 mm, 0.2 mm | - | - | - | 0.3 - 2.0 µl | 0.2 - 75A (10 mm equivalent absorbance) | - | 0.002 Abs | 0.01 | Xenon flash lamp | < 5 s | - | - | - | - | - | 10 - 3750 ng/µL (dsDNA) | 0.5 - 110 mg/mL (BSA) | - | - | - | 240 x 220 x 140 mm | 2.35 kg |
LNS-C10 | No | - | Inbuilt | 190 - 850 nm | 1 mm, 0.2 mm ,0.04 mm | ± 1 nm | 2 nm (FWHM at Hg 546 nm) | NA | 0.3 - 2.0 µl | 0 to 500 Abs | ± 1 nm | 0.002 ~ 400 Abs (10 mm) | 1 % (0.76 absorbance at 350 nm) | Xenon flash lamp | < 5 s | - | Stainless steel and quartz fiber | 2048-element linear silicon CCD | Color LCD Touchscreen display | Win7 (64-bit operating system)/Win 8 | 0.4 ~ 19000 ng/µL (dsDNA) | 0.01 ~ 400 mg/mL (BSA) | - | - | - | 350 x 240 x 220 mm | 5.2 kg |
LNS-C12 | Yes | Room Temperature 42 ºC | Inbuilt | 190 - 850 nm | 1 mm, 0.2 mm ,0.04 mm | ± 1 nm | 2 nm (FWHM at Hg 546 nm) | 1 mm/2 mm/5 mm/10 mm | 0.3 - 2.0 µl | 0 to 500 Abs | ± 1 nm | 0.002 ~ 400 Abs (10 mm) | 1 % (0.76 absorbance at 350 nm) | Xenon flash lamp | < 5 s | - | Stainless steel and quartz fiber | 2048-element linear silicon CCD | Color LCD Touchscreen display | Win7 (64-bit operating system)/Win 8 | 0.4 ~ 19000 ng/µL (dsDNA) | 0.01 ~ 400 mg/mL (BSA) | - | - | - | 350 x 240 x 220 mm | 5.2 kg |
LNS-C13 | Yes | 4 ºC - 42 ºC (Heating & Cooling) | Inbuilt | 190 - 850 nm | 1 mm, 0.2 mm ,0.04 mm | ± 1 nm | 2 nm (FWHM at Hg 546 nm) | 1 mm/2 mm/5 mm/10 mm | 0.3 - 2.0 µl | 0 to 500 Abs | ± 1 nm | 0.002 ~ 400 Abs (10 mm) | 1 % (0.76 absorbance at 350 nm) | Xenon flash lamp | < 5 s | - | Stainless steel and quartz fiber | 2048-element linear silicon CCD | Color LCD Touchscreen display | Win7 (64-bit operating system)/Win 8 | 0.4 ~ 19000 ng/µL (dsDNA) | 0.01 ~ 400 mg/mL (BSA) | - | - | - | 350 x 240 x 220 mm | 5.2 kg |
LNS-A20 | - | - | - | 190 to 850 nm | - | ± 1 nm | 2 nm (FWHM at Hg 546 nm) | 1 mm, 2 mm, 5 mm, 10 mm | - | 0.002 to 300 Abs | - | 0.002 Abs | 1 % (0.76 absorbance at 350 nm) | Xenon flash lamp | < 5 s | - | - | 3864 linear silicon CCD array | Color LCD Touchscreen display | Win7 (64-bit operating system)/Win 8 | 0.4 to 15000 ng/µL (dsDNA) | - | - | - | - | 350 × 240 × 220 mm | 5.2 kg |
LNS-B10 | - | - | - | - | 0.5 mm | - | - | - | - | 0.2 to 50 A | - | 0.005 Abs | 2% (7.332 Abs at 260 nm) | UV LED | < 6 s | - | - | - | - | - | - | - | - | - | - | - | 2 kg |
LNS-C11 | Yes | - | - | - | - | - | 2 nm (FWHM at Hg 546 nm) | 1 mm/2 mm/5 mm | - | - | - | - | - | - | < 3 s | - | Stainless steel and quartz fiber | 2048-element linear silicon CCD | Color LCD Touchscreen display | - | - | - | - | - | - | 350 × 240 × 220 mm | 5.2 kg |