Nano Spectrophotometer with full spectrum covers a wide wavelength range of 190 to 850 nm. It requires only 0.3 - 2 µl sample for measurement which takes place within 5 seconds. It uses Xenon flash lamp as light source which has high stability and long operating life. It has built in Computer, screen & four USB interface. Nano spectrophotometer connected to mouse, printer, and other wireless card devices for multiple operations.
Cuvette | Yes |
Temperature | 4 ºC - 42 ºC (Heating & Cooling) |
PC | Inbuilt |
Wavelength range | 190 - 850 nm |
Path length | 1 mm, 0.2 mm ,0.04 mm |
Wavelength accuracy | ± 1 nm |
Wavelength Resolution | 2 nm (FWHM at Hg 546 nm) |
Path length of cuvette | 1 mm/2 mm/5 mm/10 mm |
Minimum Sample size | 0.3 - 2.0 µl |
Absorbance range | 0 to 500 Abs |
Precision of wavelength | ± 1 nm |
Absorbance precision | 0.002 ~ 400 Abs (10 mm) |
Absorbance accuracy | 1 % (0.76 absorbance at 350 nm) |
Light source | Xenon flash lamp |
Measurement time | < 5 s |
Sample Pedestal Material | Stainless steel and quartz fiber |
Detector Type | 2048-element linear silicon CCD |
Screen | Color LCD Touchscreen display |
Software Compatibility | Win7 (64-bit operating system)/Win 8 |
Detects nucleic acid up to | 0.4 ~ 19000 ng/µL (dsDNA) |
Detects protein up to | 0.01 ~ 400 mg/mL (BSA) |
Dimension | 350 x 240 x 220 mm |
Weight | 5.2 kg |
The nano spectrophotometer is used in laboratory, food industries, chemistry, microbiology, medicine research and development.
Available Range :
Wavelength range : 200 - 800 nm Wavelength range : 200 - 850 nm Wavelength range : 230 nm, 260 nm, 280 nm Cuvette : No Cuvette : Yes Cuvette : YesRelated Models :
Model | Cuvette | Temperature | PC | Wavelength range | Path length | Wavelength accuracy | Wavelength Resolution | Path length of cuvette | Minimum Sample size | Absorbance range | Precision of wavelength | Absorbance precision | Absorbance accuracy | Light source | Measurement time | Operating Voltage | Sample Pedestal Material | Detector Type | Screen | Software Compatibility | Detects nucleic acid up to | Detects protein up to | Data Output | Operating Power Consumption | Standby Power Consumption | Dimension | Weight |
LNS-A10 | - | - | - | 200 - 800 nm | 0.2 mm (For high concentration measurement); 1.0 mm (For ordinary) | ± 1 nm | ≤ 3 nm (FWHM at Hg 546 nm) | - | 0.5 - 2.0 µl | 0.02 - 90 A (10mm equivalent) | - | 0.003 Abs | 1 % ( 7.332 Abs at 260 nm) | Xenon flash lamp | < 8 s | 24 V DC | Aluminum alloy and Quartz fiber | 3864-element linear silicon CCD array | - | Windows 7, Windows XP | 2 - 4500 ng/µL (dsDNA) | - | - | 20 W | 5 W | 200 x 250 x 166 mm | 2.6 kg |
LNS-A21 | - | - | - | 200 - 850 nm | 1 mm, 2 mm, 5 mm, 10 mm | ± 1 nm | 2 nm (FWHM at Hg 546 nm) | - | 0.3 - 2.0 µl | 0.00 2 ~ 75 A (150, 300 optional, 10mm equivalent absorbance) | - | 0.002 Abs | 1 % (0.76 absorbance at 350 nm) | Xenon flash lamp | < 5 s | - | - | 2048-element linear silicon CCD | - | - | 4 - 3750 ng/µL (7500,15000 optional, dsDNA) | 0.01 - 100 mg/mL (200, 400 optional, BSA) | - | - | - | 240 x 210 x 110 mm | 1.92 kg |
LNS-B11 | - | - | - | 230 nm, 260 nm, 280 nm | 1.0 mm, 0.2 mm | - | - | - | 0.3 - 2.0 µl | 0.2 - 75A (10 mm equivalent absorbance) | - | 0.002 Abs | 0.01 | Xenon flash lamp | < 5 s | - | - | - | - | - | 10 - 3750 ng/µL (dsDNA) | 0.5 - 110 mg/mL (BSA) | - | - | - | 240 x 220 x 140 mm | 2.35 kg |
LNS-C10 | No | - | Inbuilt | 190 - 850 nm | 1 mm, 0.2 mm ,0.04 mm | ± 1 nm | 2 nm (FWHM at Hg 546 nm) | NA | 0.3 - 2.0 µl | 0 to 500 Abs | ± 1 nm | 0.002 ~ 400 Abs (10 mm) | 1 % (0.76 absorbance at 350 nm) | Xenon flash lamp | < 5 s | - | Stainless steel and quartz fiber | 2048-element linear silicon CCD | Color LCD Touchscreen display | Win7 (64-bit operating system)/Win 8 | 0.4 ~ 19000 ng/µL (dsDNA) | 0.01 ~ 400 mg/mL (BSA) | - | - | - | 350 x 240 x 220 mm | 5.2 kg |
LNS-C12 | Yes | Room Temperature 42 ºC | Inbuilt | 190 - 850 nm | 1 mm, 0.2 mm ,0.04 mm | ± 1 nm | 2 nm (FWHM at Hg 546 nm) | 1 mm/2 mm/5 mm/10 mm | 0.3 - 2.0 µl | 0 to 500 Abs | ± 1 nm | 0.002 ~ 400 Abs (10 mm) | 1 % (0.76 absorbance at 350 nm) | Xenon flash lamp | < 5 s | - | Stainless steel and quartz fiber | 2048-element linear silicon CCD | Color LCD Touchscreen display | Win7 (64-bit operating system)/Win 8 | 0.4 ~ 19000 ng/µL (dsDNA) | 0.01 ~ 400 mg/mL (BSA) | - | - | - | 350 x 240 x 220 mm | 5.2 kg |
LNS-C13 | Yes | 4 ºC - 42 ºC (Heating & Cooling) | Inbuilt | 190 - 850 nm | 1 mm, 0.2 mm ,0.04 mm | ± 1 nm | 2 nm (FWHM at Hg 546 nm) | 1 mm/2 mm/5 mm/10 mm | 0.3 - 2.0 µl | 0 to 500 Abs | ± 1 nm | 0.002 ~ 400 Abs (10 mm) | 1 % (0.76 absorbance at 350 nm) | Xenon flash lamp | < 5 s | - | Stainless steel and quartz fiber | 2048-element linear silicon CCD | Color LCD Touchscreen display | Win7 (64-bit operating system)/Win 8 | 0.4 ~ 19000 ng/µL (dsDNA) | 0.01 ~ 400 mg/mL (BSA) | - | - | - | 350 x 240 x 220 mm | 5.2 kg |
LNS-A20 | - | - | - | 190 to 850 nm | - | ± 1 nm | 2 nm (FWHM at Hg 546 nm) | 1 mm, 2 mm, 5 mm, 10 mm | - | 0.002 to 300 Abs | - | 0.002 Abs | 1 % (0.76 absorbance at 350 nm) | Xenon flash lamp | < 5 s | - | - | 3864 linear silicon CCD array | Color LCD Touchscreen display | Win7 (64-bit operating system)/Win 8 | 0.4 to 15000 ng/µL (dsDNA) | - | - | - | - | 350 × 240 × 220 mm | 5.2 kg |
LNS-B10 | - | - | - | - | 0.5 mm | - | - | - | - | 0.2 to 50 A | - | 0.005 Abs | 2% (7.332 Abs at 260 nm) | UV LED | < 6 s | - | - | - | - | - | - | - | - | - | - | - | 2 kg |
LNS-C11 | Yes | - | - | - | - | - | 2 nm (FWHM at Hg 546 nm) | 1 mm/2 mm/5 mm | - | - | - | - | - | - | < 3 s | - | Stainless steel and quartz fiber | 2048-element linear silicon CCD | Color LCD Touchscreen display | - | - | - | - | - | - | 350 × 240 × 220 mm | 5.2 kg |