info@labtron.com +44 2080 043608

Single Beam UV/Visible Spectrophotometer LUS-A40

Single Beam UV/Vis Spectrophotometer is formulated with large LCD display screen and 4 cell holder capacity. It has full functionality from 190 – 1100 nm range of wavelength. It has wide range spectral bandwidth of 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm. This single beam spectrophotometer has highly stable optics with 1200 lines/mm grating. Spectrophotometer is complied using ISO/CE international standards. It is particularly designed to meet its versatility in research and industries.

Request Quote
Wavelength Range 190 ~ 1100 nm
Spectral Bandwidth 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm
Wavelength Accuracy ± 0.3 nm
Wavelength Repeatability 0.2 nm
Photometric Range 0 - 200 % T, (-0.3) to (-3.0)A, 0 - 9999 C
Photometric Accuracy ± 0.3 % T
Photometric Repeatability 0.2 % T
Detector Silicon Photodiode
Light Source Deuterium & Tungsten Halogen Lamp
Stray Light ≤ 0.05 % T at 220 nm, 360 nm
Stability 0.002 A / h at 500 nm
Data Output Port USB
Power Requirement AC 220 V / 50 Hz, 110 V / 60 Hz.
Noise ± 0.001 A
Display LCD Display resolution 320 × 240 Dots LCD
Optical System Single Beam (1200 lines / mm grating)
Baseline Flatness ± 0.001 A
Printer Port Parallel Port
Packing Size 860 x 660 x 465 mm
Packing Weight 35 kg
  • Single beam spectrophotometer
  • Wavelength range 190 nm to 1100 nm
  • Wide range of bandwidth 0.5 / 1.0 /2.0 / 4.0 / 5.0 nm with PC software
  • Optical system with 1200 lines / mm grating
  • 4 cell holder available along with USB port for data storage
  • 6 inches LCD display & integrated user interface
  • Extensive range of accessories available

Single Beam UV/Vis Spectrophotometer is ideal for quality control, general research, pharmaceuticals, biochemical and clinical laboratory applications.

Compare Models

Model Wavelength Range Setting Wavelength Spectral Bandwidth Wavelength Accuracy Wavelength Repeatability Photometric Range Photometric Mode Photometric Accuracy Photometric Repeatability Transmittance accuracy Transmittance repeatability Detector Light Source Stray Light Stability Data Output Port Power Requirement Dimensions Noise Weight Gross Weight Net Weight Power Display LCD Optical System Baseline Linearity Baseline Drift Baseline Flatness Printer Port Packing Size Software Packing Weight
LUS-A50 - - - ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all ≤ 0.1 nm 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F) - 0.2%T (0 to 100 %T), ±0.002A(0 to 0.5 A), ±0.004A (0.5 to 1 A) ≤0.15 % T (0 to 100 %T), 0.001A (0 to 0.5A), 0.002A (0.5 to 1A) - - Imported silicon photodiode - - ± 0.0005 A/h @ 500 nm USB drive, USB host, RS232 - - 0.0005 A @ 500 nm - - - - - - - - - - - - -
LUS-A51 - - - ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all ≤ 0.1 nm 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F) - 0.2%T (0 to 100 %T), ±0.002A(0 to 0.5 A), ±0.004A (0.5 to 1 A) ≤0.15 % T (0 to 100 %T), 0.001A (0 to 0.5A), 0.002A (0.5 to 1A) - - Imported silicon photodiode - - ± 0.0005 A/h @ 500 nm USB drive, USB host, RS232 - - 0.0005 A @ 500 nm - - - - - - - - - - - - -
LUS-A52 - - - ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all ≤ 0.1 nm 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F) - 0.2%T (0 to 100 %T), ±0.002A(0 to 0.5 A), ±0.004A (0.5 to 1 A) ≤0.15 % T (0 to 100 %T), 0.001A (0 to 0.5A), 0.002A (0.5 to 1A) - - Imported silicon photodiode - - ± 0.0005 A/h @ 500 nm USB drive, USB host, RS232 - - 0.0005 A @ 500 nm - - - - - - - - - - - - -
LUS-A10 190 ~ 1100 nm - 1 nm ± 0.3 nm 0.2 nm 0 - 200 % T, (-0.3) to (-3.0) A, 0 - 9999 C - ± 0.3 % T 0.2 % T - - Silicon Photodiode Deuterium & Tungsten Halogen Lamp ≤ 0.05 % T at 220 nm, 360 nm 0.002 A / h at 500 nm USB AC 220 V / 50 Hz, 110 V / 60 Hz. - ± 0.001 A - - - - - Single Beam (1200 lines / mm grating) - - ± 0.001 A Parallel Port 860 x 660 x 465 mm - 35 kg
LUS-A11 190 ~ 1100 nm - 1.8 nm ± 0.3 nm 0.2 nm 0 - 200 % T, (-0.3) to (-3.0) A, 0 - 9999 C - ± 0.3 % T 0.2 % T - - Silicon Photodiode Deuterium & Tungsten Halogen Lamp ≤ 0.05 % T at 220 nm, 360 nm 0.002 A / h at 500 nm USB AC 220 V / 50 Hz, 110 V / 60 Hz. - ± 0.001 A - - - - - Single Beam (1200 lines / mm grating) - - ± 0.001 A Parallel Port 860 x 660 x 465 mm - 35 kg
LUS-A20 190 ~ 1100 nm Automatic 2 nm ± 0.5 nm ≤ 0.2 nm (-0.3) ~ 3 A T,A,C,E ± 0.3 % T 0.15 % τ - - Import Silicon Photodiode Import Deuterium Lamp & Tungsten Halogen Lamp ≤ 0.05 % T at 220 nm, 360 nm 0.001 A / h at 500 nm - AC 220 V / 50 Hz, 110 V / 60 Hz. 480 × 350 × 220 mm - 15 kg - - 120 W Display resolution 128 × 64 Dots LCD - - - - - - - 15 kg
LUS-A21 190 ~ 1100 nm Automatic 1.8 nm ± 0.3 nm ≤ 0.1 nm (-4) to 4A T,A,C,E ± 0.3 % τ(0 - 100 % τ) ; ± 0.002A(0 ~ 0.5 A) ; ± 0.003 A (0.5 A ~ 1 A) 0.15% τ(0-100%τ); ± 0.001 A(0 ~ 0.5 A) ; ± 0.0015 A(0.5 A ~ 1 A) - - Import Silicon Photodiode Import Deuterium Lamp & Tungsten Halogen Lamp ≤ 0.05 % T at 220 nm, 360 nm 0.0005 A / h at 500 nm - AC 220 V / 50 Hz, 110 V / 60 Hz. 560 × 450 × 230 mm ± 0.0002 A at 500 nm 28 kg - - 120 W 6 inches blue LCD - - - ± 0.001 A - - - 28 kg
LUS-A30 190 ~ 1100 nm Automatic 4 nm ± 0.5 nm ≤ 0.2 nm (-0.3) ~ 3 A T,A,C,E ± 0.3 % T 0.15 % τ - - Import Silicon Photodiode Import Deuterium Lamp & Tungsten Halogen Lamp ≤ 0.05 % T at 220 nm, 360 nm 0.001 A / h at 500 nm - AC 220 V / 50 Hz, 110 V / 60 Hz. 480 × 350 × 220 mm - 15 kg - - 120 W Display resolution 128 × 64 Dots LCD - - - - - - - -
LUS-A40 190 ~ 1100 nm - 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm ± 0.3 nm 0.2 nm 0 - 200 % T, (-0.3) to (-3.0)A, 0 - 9999 C - ± 0.3 % T 0.2 % T - - Silicon Photodiode Deuterium & Tungsten Halogen Lamp ≤ 0.05 % T at 220 nm, 360 nm 0.002 A / h at 500 nm USB AC 220 V / 50 Hz, 110 V / 60 Hz. - ± 0.001 A - - - - Display resolution 320 × 240 Dots LCD Single Beam (1200 lines / mm grating) - - ± 0.001 A Parallel Port 860 x 660 x 465 mm - 35 kg
LUS-A22 190 ~ 1100 nm - 0.5 nm, 1 nm, 2 nm, 4 nm adjustable ± 0.3 nm ≤ 0.1 nm (-4)A to 4 A T,A,C,E ± 0.3 % τ(0 - 100 % τ) ± 0.002 A (0 to 0.5 A) ± 0.003 A(0.5 A to 1 A) 0.15 % τ(0 - 100 % τ); ± 0.001 A(0 to 0.5 A); ± 0.0015 A(0.5 A to 1 A) - - Imported Silicon Photodiode Imported Deuterium Lamp & Tungsten Halogen Lamp ≤ 0.05 % T at 220 nm, 360 nm 0.0005 A / h at 500 nm - AC 220 V / 50 Hz, 110 V / 60 Hz. 560 × 450 × 230 mm ± 0.0002 A at 500 nm 28 kg - - 120 W 6 inches blue LCD - - - ± 0.001 A - - - -
LUS-C10 200 to 1000 nm - 4.0 nm ±0.2 nm 0.2 nm - T, A, C, E ±0.2% τ 0.2% τ - - Silicon photodiode Tungsten lamp, Deuterium lamp ≤0.05% τ (220 nm NaI, 340 nm NaNO2) 0.001 A/h @500 nm - - - ± 0.002 A @500 nm - - 11 kg - - - - - ± 0.001 A - - - -

Most Viewed

Customer Enquiry Form

Ask Expert

Address: Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608

Copyright © 2023 Labtron Equipment Ltd. All rights reserved.