Temperature and Humidity Test Chamber LTHC-B20 is designed to simulate constant climatic conditions for testing a wide variety of products for their quality, performance, shelf life and stability. It's used to simulate constant temperature and humidity conditions, thereby creating a physiologically ideal environment for product testing. A good temperature humidity chamber is essential for evaluating potential success or failure of a product in the field.
Capacity | 100 L |
Temperature range | (-70 )℃ to 150 ℃ |
Temperature cooling rate | 5 ℃ / min |
Overall dimension (D x W x H) | 860 x 1050 x 1620 mm |
Temperature heating rate | 3 ℃ / min |
Temperature fluctuations | ± 0.5 ℃ |
Temperature deviation | ± 2.0 ℃ |
Humidity range | 20 % ~ 98 % R.H |
Humidity deviation | ± 2.5 % RH |
High temperature | 180 ℃ |
Lowest humidity | 10 % RH |
Internal dimension (D x W x H) | 400 x 500 x 500 mm |
Extensively used in basic and advanced research, pharmaceutical industries, chemical industries, food and beverage industry.
Available Range :
Capacity : 50 L Capacity : 80 L Capacity : 100 L Capacity : 225 L Capacity : 500 L Capacity : 800 LRelated Models :
Model | Capacity | Temperature range | Temperature cooling rate | Overall dimension (D x W x H) | Temperature heating rate | Temperature fluctuations | Temperature deviation | Humidity range | Humidity deviation | High temperature | Lowest humidity | Internal dimension (D x W x H) |
LTHC-A10 | 50 L | (- 20 °C) to 150 °C | - | - | - | - | ± 2 °C | 20 % - 98 % RH | ± 2.5 % RH | - | - | - |
LTHC-A11 | 80 L | (- 20 °C) to 150 °C | - | - | - | - | ± 2 °C | 20 % - 98 % RH | ± 2.5 % RH | - | - | - |
LTHC-B10 | 100 L | (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃ | 1 ℃ / min | 860 x 1050 x 1620 mm | 3 ℃ / min | ± 0.5 ℃ | ± 2.0 ℃ | 20 % ~ 98 % R.H | ± 2.5 % RH | 180 ℃ | 10 % RH | 400 x 500 x 500 mm |
LTHC-B11 | 225 L | (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃ | 1 ℃ / min | 960 x 1150 x 1860 mm | 3 ℃ / min | ± 0.5 ℃ | ± 2.0 ℃ | 20 % ~ 98 % R.H | ± 2.5 % RH | 180 ℃ | 10 % RH | 500 x 600 x 750 mm |
LTHC-B12 | 500 L | (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃ | 1 ℃ / min | 1180 x 1350 x 2010 mm | 3 ℃ / min | ± 0.5 ℃ | ± 2.0 ℃ | 20 % ~ 98 % R.H | ± 2.5 % RH | 180 ℃ | 10 % RH | 700 x 800 x 900 mm |
LTHC-B13 | 800 L | (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃ | 1 ℃ / min | 1280 x 1550 x 2110 mm | 3 ℃ / min | ± 0.5 ℃ | ± 2.0 ℃ | 20 % ~ 98 % R.H | ± 2.5 % RH | 180 ℃ | 10 % RH | 800 x 1000 x 1000 mm |
LTHC-B14 | 1000 L | (-20)℃ to 150 ℃ ,(-40) ℃ to 150 ℃ , (-70 )℃ to 150 ℃ | 1 ℃ / min | 1500 x 1550 x 2110 mm | 3 ℃ / min | ± 0.5 ℃ | ± 2.0 ℃ | 20 % ~ 98 % R.H | ± 2.5 % RH | 180 ℃ | 10 % RH | 1000 x 1000 x 1000 mm |
LTHC-B20 | 100 L | (-70 )℃ to 150 ℃ | 5 ℃ / min | 860 x 1050 x 1620 mm | 3 ℃ / min | ± 0.5 ℃ | ± 2.0 ℃ | 20 % ~ 98 % R.H | ± 2.5 % RH | 180 ℃ | 10 % RH | 400 x 500 x 500 mm |
LTHC-B21 | 225 L | (-70 )℃ to 150 ℃ | 5 ℃ / min | 960 x 1150 x 1860 mm | 3 ℃ / min | ± 0.5 ℃ | ± 2.0 ℃ | 20 % ~ 98 % R.H | ± 2.5 % RH | 180 ℃ | 10 % RH | 500 x 600 x 750 mm |
LTHC-B22 | 500 L | (-70 )℃ to 150 ℃ | 5 ℃ / min | 1180 x 1350 x 2010 mm | 3 ℃ / min | ± 0.5 ℃ | ± 2.0 ℃ | 20 % ~ 98 % R.H | ± 2.5 % RH | 180 ℃ | 10 % RH | 700 x 800 x 900 mm |
LTHC-B23 | 800 L | (-70 )℃ to 150 ℃ | 5 ℃ / min | 1280 x 1550 x 2110 mm | 3 ℃ / min | ± 0.5 ℃ | ± 2.0 ℃ | 20 % ~ 98 % R.H | ± 2.5 % RH | 180 ℃ | 10 % RH | 800 x 1000 x 1000 mm |
LTHC-B24 | 1000 L | (-70 )℃ to 150 ℃ | 5 ℃ / min | 1500 x 1550 x 2110 mm | 3 ℃ / min | ± 0.5 ℃ | ± 2.0 ℃ | 20 % ~ 98 % R.H | ± 2.5 % RH | 180 ℃ | 10 % RH | 1000 x 1000 x 1000 mm |
LTHC-B30 | 3150 L | -40℃ to 150℃ | 1℃ / min | - | 1℃ / min | ± 0.5℃ | ± 2.0℃ | 10% to 98% RH | ± 2.5 % RH | - | - | - |
LTHC-C10 | - | - | - | - | - | - | - | - | - | - | - | - |
LTHC-C20 | 150 L | 10 to 70°C | - | - | - | - | - | 40 to 95% | - | - | - | - |
LTHC-B25 | 1500 L | (-60) ℃ to +150 ℃ | 3 ℃ / min | - | 3 ℃ / min | - | ± 1.0 ℃ | 10% to 98% RH | ± 2.5 % RH | - | - | - |