info@labtron.com +44 2080 043608
Radio Frequency Identification Water Purification System LRFW-A11

Radio Frequency Identification Water Purification System LRFW-A11

Radio Frequency Identification Water Purification System LRFW-A11 is a 30 L capacited revolutionary, modular design which helps in elimination of large amount of salts and other minerals from tap water, using RO with the least TOC level i.e. < 3 ppb. This system produce and reject water at the same time. The unique feature of this model is that it’s equipped with a RFID Radio Frequency Identification Chip which helps keeping a check on the quality of water in real time. It’s designed to deliver compliant purified water with clear quality parameters and care free maintenance

Request Quote
Output of Pure water ≥ 20 L / hr.
Process Single Pass RO system
Configuration Benchtop
Water Tank capacity 30 L
Output of Ultrapure water ≥ 1- 1.5 L / min
Resistivity at 25 °C 18.25 M Ω. cm
Conductivity at 25 °C ≤ 10 µs / cm
TOC < 3 ppb
Pyrogens / Endotoxins < 0.025 EU / ml
Bacteria < 1 cfu / ml
Particles ( > 0.22 µm ) < 1 / ml
Absorbance ( 254 nm ) ≤ 0.001
Reactive Silica ( SiO2 ) < 0.01 ppm
Heavy metal < 0.01 ppm
Electrical requirements 220 V / 50 Hz
Power ≥ 150 W
Dimensions ( L x W x H ) 340 x 550 x 530 mm
Weight 34 kg
  • Radio Frequency Identification Chip integrated
  • Advanced Single Pass reverse osmosis system for excellent water quality
  • Equipped with 30 L water holding tank
  • Least TOC level < 3 ppb
  • Source of inlet water – Tap water
  • Benchtop model
  • LCD display to display the intake of water pressure and various parameters intuitively
  • Programmed water shortage protection alarm
  • Anti-fouling RO membrane prevention programme
  • Online monitoring of water resistance
  • Ease of cleansing , disinfecting and draining waste water
  • Micro filter membrane to filter out pollutants
  • Automatic RO membrane antiscale flushing to extend the life of the RO membrane

Used in PCR / DNA preparation, HPLC, LC-MS, electrophoresis, chemical analysis experiment, protein analysis

Compare Models

Model Output of Pure water Process Configuration Water Tank capacity Output of Ultrapure water Resistivity at 25 °C Conductivity at 25 °C TOC Pyrogens / Endotoxins Bacteria Particles ( > 0.22 µm ) Absorbance ( 254 nm ) Reactive Silica ( SiO2 ) Heavy metal Electrical requirements Power Dimensions ( L x W x H ) Weight
LRFW-B10 ≥ 10 L / hr. Double Pass RO system Benchtop 30 L ≥ 1- 1.5 L / min 18.25 M Ω. cm ≤ 5 µs / cm < 3 ppb < 0.025 EU / ml < 1 cfu / ml < 1 / ml ≤ 0.001 < 0.01 ppm < 0.01 ppm 220 V / 50 Hz ≥ 150 W 340 x 550 x 530 mm 45 kg
LRFW-B11 ≥ 20 L / hr. Double Pass RO system Benchtop 30 L ≥ 1- 1.5 L / min 18.25 M Ω. cm ≤ 5 µs / cm < 3 ppb < 0.025 EU / ml < 1 cfu / ml < 1 / ml ≤ 0.001 < 0.01 ppm < 0.01 ppm 220 V / 50 Hz ≥ 200 W 340 x 550 x 530 mm 45 kg
LRFW-B12 ≥ 30 L / hr. Double Pass RO system Benchtop 30 L ≥ 1- 1.5 L / min 18.25 M Ω. cm ≤ 5 µs / cm < 3 ppb < 0.025 EU / ml < 1 cfu / ml < 1 / ml ≤ 0.001 < 0.01 ppm < 0.01 ppm 220 V / 50 Hz ≥ 450 W 340 x 550 x 530 mm 45 kg
LRFW-B13 ≥ 40 L / hr. Double Pass RO system Floor standing 80 L ≥ 1- 1.5 L / min 18.25 M Ω. cm ≤ 5 µs / cm < 3 ppb < 0.025 EU / ml < 1 cfu / ml < 1 / ml ≤ 0.001 < 0.01 ppm < 0.01 ppm 220 V / 50 Hz ≥ 450 W 340 x 550 x 530 mm 45 kg
LRFW-B14 ≥ 50 L / hr. Double Pass RO system Floor Standing 80 L ≥ 1- 1.5 L / min 18.25 M Ω. cm ≤ 5 µs / cm < 3 ppb < 0.025 EU / ml < 1 cfu / ml < 1 / ml ≤ 0.001 < 0.01 ppm < 0.01 ppm 220 V / 50 Hz ≥ 550 W 340 x 550 x 530 mm 45 kg
LRFW-A10 ≥ 10 L / hr. Single Pass RO system Benchtop 30 L ≥ 1- 1.5 L / min 18.25 M Ω. cm ≤ 10 µs / cm < 3 ppb < 0.025 EU / ml < 1 cfu / ml < 1 / ml ≤ 0.001 < 0.01 ppm < 0.01 ppm 220 V / 50 Hz ≥ 100 W 340 x 550 x 530 mm 34 kg
LRFW-A11 ≥ 20 L / hr. Single Pass RO system Benchtop 30 L ≥ 1- 1.5 L / min 18.25 M Ω. cm ≤ 10 µs / cm < 3 ppb < 0.025 EU / ml < 1 cfu / ml < 1 / ml ≤ 0.001 < 0.01 ppm < 0.01 ppm 220 V / 50 Hz ≥ 150 W 340 x 550 x 530 mm 34 kg
LRFW-A12 ≥ 30 L / hr. Single Pass RO system Benchtop 30 L ≥ 1- 1.5 L / min 18.25 M Ω. cm ≤ 10 µs / cm < 3 ppb < 0.025 EU / ml < 1 cfu / ml < 1 / ml ≤ 0.001 < 0.01 ppm < 0.01 ppm 220 V / 50 Hz ≥ 200 W 340 x 550 x 530 mm 34 kg
LRFW-A13 ≥ 40 L / hr. Single Pass RO system Floor Standing 80 L ≥ 1- 1.5 L / min 18.25 M Ω. cm ≤ 10 µs / cm < 3 ppb < 0.025 EU / ml < 1 cfu / ml < 1 / ml ≤ 0.001 < 0.01 ppm < 0.01 ppm 220 V / 50 Hz ≥ 200 W 340 x 550 x 530 mm 34 kg
LRFW-A14 ≥ 50 L / hr. Single Pass RO system Floor Standing 80 L ≥ 1- 1.5 L / min 18.25 M Ω. cm ≤ 10 µs / cm < 3 ppb < 0.025 EU / ml < 1 cfu / ml < 1 / ml ≤ 0.001 < 0.01 ppm < 0.01 ppm 220 V / 50 Hz ≥ 350 W 340 x 550 x 530 mm 34 kg
LRFW-C10 - - - - - - - < 5 ppb - - - - - - - - - 36 kg

Most Viewed