Labtron Distillation Tester determine boiling point characteristics for analyzing purity and composition of substance. Their high-quality glass components ensure visibility while withstanding rigors of use. They utilize energy-efficient heating elements to minimize power consumption during lengthy processing. Their innovative design minimizes cross-contamination risks between different fractions, ensuring purity. Our Distillation Tester is suitable for oil and gas industry to assess crude oil fractions and in pharmaceuticals to check solvent purity.
Heating Power: 2 KW
Refrigeration Power: 0.5 KW
Standard: ASTM D86
Display: 10.4-inch large color touchscreen
Graduated flasks: 10 ml and 100 ml
Scale division of graduated flask: 10 ml is 0.1 ml and 100 ml is 1 ml
Ambient temperature: (-10) °C ~ 35 °C
Relative humidity: ≤ 85 %
Ambient temperature: -10°C to 35°C
Relative humidity: ≤ 85 %
Thermometer: Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
Scale division: 0.1 ℃
Graduated flasks: 100 ml
Scale division of graduated flask: 1 ml
Outer diameter of distillation flask: φ65
Refrigeration tube: φ14
Ambient temperature: 5 °C to 35 ℃
Relative humidity: ≤ 85 %
Cubage of buffer vessel: 1000 ml
Max. Residual pressure: ≤ 2 mm Hg
Distillation flask: 125 mL
Ambient temperature: Room temperature to 35 °C
Relative humidity: ≤ 85 %
Thermometer: (-2 )°C to 300 ℃ and (-2) °C to 400 ℃
Graduated flasks: 100 ml
Scale division of graduated flask: 1ml
Distillation flask: 125 ml
Ambient temperature: ≤ 35 °C
Distillation Flask: 125 ml
Graduated Flasks: 100 ml
Ambient Temperature: ≤ 35 °C
Relative Humidity: ≤ 85 %
Distillation Flask: 125 ml
Graduated Flasks: 100 ml
Ambient Temperature: ≤ 30 °C
Relative Humidity: ≤ 85 %
Evaporation tube specifications: 200 Φ mm
Evaporation tube heat transfer area: 0.4 m2
Built-in cooling area: 0.5 m2
Constant pressure feeding bottle: 3 L
Test Range: Temperature Range: 0~400℃ Accuracy: ±0.1℃ (PT100 Probe)
Receiving Chamber: Temp. Range: 0~60℃ (0℃ can be reached when AT is below 15℃) Accuracy: ±0.1℃
Condenser Bath: Peltier cooling Temp. Range: 0~60 ℃ (0℃ can be reached when AT is below 25℃) Accuracy: ± 0.1℃
Heating System: Low mass/low voltage heater Unique heating optimization system for fully automatic initial heat settings and heating regulation
Temperature Range: AT to 400℃
Left Bath Temperature Range: 0 to 60℃, Accuracy: ±0.5℃
Right Bath Temperature Range: 0 to 60℃, Accuracy: ±0.5℃
Receiving Chamber Temperature Range: 0℃ to AT (Auto control)
Address:Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608