Labtron UV-Vis double beam Spectrophotometers are small, tabletop devices with twin beam designs that span a wide range of wavelengths. They have silicon photodiode detectors, automatic wavelength adjustments, and tungsten and deuterium lamps. These feature LCD displays and USB ports for data storage and transportation. They provide a variety of measurement methods to satisfy various analytical needs. Our double beam spectrophotometers have exceptional performance and durability, auto calibration, user-friendly interfaces, and enhanced optics for precision.
Wavelength Range : 190 to 1100 nm
Spectral Bandwidth : 1.8 nm
Optical System : Double beam
Wavelength Accuracy : ±0.3 nm
Wavelength range : 190 to 1100 nm
Spectral bandwidth : 1.8 nm
Optical system : Double beam; 1200 lines/mm grating
Wavelength accuracy : ±0.1nm (D2 656.1nm), ±0.3nm @ all
Wavelength Range : 190 to 1100 nm
Spectral Bandwidth : 1.8 nm
Optical System : Double beam, C-T monochromator,1200 L/mm holographic grating
Wavelength Accuracy : ±0.3 nm
Wavelength Range : 190 to 1100 nm
Spectral Bandwidth : 1.0 nm
Optical System : Double beam
Wavelength Accuracy : ±0.3 nm
Wavelength range : 190 ~ 1100 nm
Spectral bandwidth : 2 nm
Wavelength accuracy : 0.5 nm
Wavelength repeatability : ≤ 0.2 nm
Optical System : Double beam
Wavelength Range : 190 to 1100 nm
Band Width : 0.5 / 1.0 / 2.0 / 4.0 nm adjustable
Wavelength Setting : Automatic
Optical System : Double beam
Wavelength Range : 190 to 1100 nm
Band Width : 1.8 nm
Wavelength Accuracy : ± 0.3 nm
Wavelength range : 190 to 1100 nm
Spectral bandwidth : 1.0 to 5.0 nm (adjustable)
Optical system : Double beam, C-T monochromator, 1600 L/mm holographic grating
Wavelength accuracy : ±0.3 nm
Wavelength Range : 190 to 900nm
Spectral Bandwidth : 4nm, 2nm, 1nm, 0.5nm, 0.2nm, 0.1nm
Optical System : Double beam
Wavelength Accuracy : ±0.1nm
Wavelength range : 190 to 1100 nm
Spectral bandwidth : 2 nm
Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability : ≤ 0.1 nm
Wavelength range : 190 to 1100 nm
Spectral bandwidth : 1 nm
Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability : ≤ 0.1 nm
Wavelength range : 190 to 1100 nm
Spectral bandwidth : 0.5/1/2/4/5 nm
Wavelength Accuracy : ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all
Wavelength Repeatability : ≤ 0.1 nm
Wavelength Range : 190 to 1100 nm
Spectral Bandwidth : 0.5/1/2/4/5 nm
Wavelength Accuracy : ±0.3nm
Wavelength Repeatability : ≤ 0.1nm
Wavelength range : 190 to 1100 nm
Spectral bandwidth : 0.5/1/2/4 nm
Wavelength Accuracy : ± 0.1nm (D2, 656.1 nm), ± 0.3 nm full range
Wavelength Repeatability : ≤ 0.1 nm
Wavelength Range : 190 to 1100 nm
Wavelength Accuracy : ± 0.3 nm
Wavelength Repeatability : ≤ 0.2 nm
Spectral Bandwidth : 1.8/1.0 nm
Wavelength Range : 190nm to 1100nm
Wavelength Accuracy : ± 0.3nm
Wavelength Repeatability : ≤ 0.1nm
Spectral Bandwidth : 0.5 to 6.0nm
Wavelength Range : 190 to 1100nm
Wavelength Accuracy : ±0.3nm
Wavelength Repeatability : ≤ 0.1nm
Spectral Bandwidth : 2nm or 1nm
Wavelength Range : 190 to 1100nm
Spectral Bandwidth : 6 nm
Wavelength Accuracy : ± 2nm
Wavelength Repeatability : ≤ 1nm
Wavelength Range : 190 to 1100 nm
Spectral Bandwidth : 5 nm
Wavelength Accuracy : ± 1.8 nm
Wavelength Repeatability : ≤ 1 nm
Optical System : Double beam
Wavelength Range : 190 to 1100 nm
Spectral Bandwidth : 1.0 nm
Wavelength Accuracy : ±0.3 nm
Address: Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608