info@labtron.com +44 2080 043608
Double Beam UV/Vis Spectrophotometer LUS-B16

Double Beam UV/Vis Spectrophotometer LUS-B16

Double beam UV/Vis spectrophotometer LUS-B16 is fully automated with improved and optimized optical path design to give highly accurate and reliable measurements. This double beam spectrophotometer offers four customized spectral bandwidth ranges from (4 nm, 2 nm, 1 nm, 0.5 nm) to meet the market needs. The wide range of measurement methods e.g. wavelength scanning, time scanning, microarray measurement meets the different range of applications.

Request Quote
Wavelength Range 190 ~ 1100 nm
Setting Wavelength Automatic
Spectral Bandwidth 0.5 / 1.0 / 2.0 / 4.0 nm adjustable
Wavelength Accuracy ± 0.3 nm
Wavelength Repeatability ≤ 0.1 nm
Photometric Range (-4) ~ 4 A
Photometric Mode T,A,C,E
Photometric Accuracy ± 0.3 % τ(0 - 100 % τ) ; ± 0.002 A (0 ~ 0.5 A) ; ± 0.003 A(0.5 A ~ 1 A)
Photometric Repeatability 0.15 % τ(0 -100 % τ); ± 0.001 A(0 ~ 0.5 A) ; ± 0.0015 A(0.5 A ~ 1 A)
Stray Light ≤ 0.03 % τ (220 nm NaI, 340 nm NaNO2)
Power Requirement AC 220 V / 50 Hz, 110 V / 60 Hz.
Dimensions 560 × 450 × 230 mm
Noise ± 0.0002A @500nm
Weight 28 kg
Power 120 W
Display LCD 6 inches blue LCD
Optical System Double beam
Baseline Flatness ± 0.001 A
  • Wide wavelength range of 190 - 1100 nm
  • 4 spectral bandwidth (4.0 nm, 2.0 nm, 1.0 nm, 0.5 nm)
  • 6 inches large LCD screen to display measurement parameters & readings
  • Improved and optimized optical design
  • Automatic wavelength adjustment
  • Wide range of measurement methods: wavelength scanning, time scanning, microarray measurement
  • Adapted with PC software to measure more precise measurements
  • Large scale integrated circuit design to improve the scalability and reliability of the system
  • Measurement data can be output through the printer with USB interface
  • Improved scalability and reliability of the system through LSI design

The double beam UV/VIS spectrophotometer has applications in pharmaceutical analysis, biological research, chemistry, environmental science, food science, medicine & other fields.

Accessory No Accessory Quantity
1 1 cm quartz cuvette 2
2 1 cm glass cuvette 4
3 Dust cover 1
4 Power line 1

Hole rack
Automatic rack with eight hole stand
Automatic English frame
Glass stand
Test tube rack
1 cm colorimetric frame
5 cm colorimetric frame
10 cm colorimetric rack

Compare Models

Model Wavelength Range Setting Wavelength Spectral Bandwidth Wavelength Accuracy Wavelength Repeatability Photometric Range Photometric Mode Photometric Accuracy Photometric Repeatability Transmittance accuracy Transmittance repeatability Detector Light Source Stray Light Stability Data Output Port Power Requirement Dimensions Noise Weight Gross Weight Net Weight Power Display LCD Optical System Baseline Linearity Baseline Drift Baseline Flatness Printer Port Packing Size Software Packing Weight
LUS-B30 - - - ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all ≤ 0.1 nm 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F) - 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F) ≤0.15 % T (0 to 100 %T), 0.001A (0 to 0.5A), 0.002A (0.5 to 1A) - - Imported silicon photodiode - - ± 0.0003 A/h @ 500 nm USB drive, USB host, RS232 - - 0.0005 A @ 500 nm - - - - - - - - - - - - -
LUS-B31 - - - ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all ≤ 0.1 nm 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F) - 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F) ≤0.15 % T (0 to 100 %T), 0.001A (0 to 0.5A), 0.002A (0.5 to 1A) - - Imported silicon photodiode - - ± 0.0003 A/h @ 500 nm USB drive, USB host, RS232 - - 0.0005 A @ 500 nm - - - - - - - - - - - - -
LUS-B32 - - - ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all ≤ 0.1 nm 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F) - 0 to 200 %T, -0.3 to 3A, 0 to 9999 C (0 to 9999F) ≤0.15 % T (0 to 100 %T), 0.001A (0 to 0.5A), 0.002A (0.5 to 1A) - - Imported silicon photodiode - - ± 0.0003 A/h @ 500 nm USB drive, USB host, RS232 - - 0.0005 A @ 500 nm - - - - - - - - - - - - -
LUS-B16 190 ~ 1100 nm Automatic 0.5 / 1.0 / 2.0 / 4.0 nm adjustable ± 0.3 nm ≤ 0.1 nm (-4) ~ 4 A T,A,C,E ± 0.3 % τ(0 - 100 % τ) ; ± 0.002 A (0 ~ 0.5 A) ; ± 0.003 A(0.5 A ~ 1 A) 0.15 % τ(0 -100 % τ); ± 0.001 A(0 ~ 0.5 A) ; ± 0.0015 A(0.5 A ~ 1 A) - - - - ≤ 0.03 % τ (220 nm NaI, 340 nm NaNO2) - - AC 220 V / 50 Hz, 110 V / 60 Hz. 560 × 450 × 230 mm ± 0.0002A @500nm 28 kg - - 120 W 6 inches blue LCD Double beam - - ± 0.001 A - - - -
LUS-B40 - - - ± 0.1nm (D2, 656.1 nm), ± 0.3 nm full range ≤ 0.1 nm 0 to 200 %T, -0.3 to 3.0 A, 0 to 9999 C (0 to 9999F) -
± 0.2T (0 to 1009 % T)
± 0.002 Abs (0 to 0.5 Abs)
± 0.004 Abs (0.5 to1.0 Abs)
≤ 0.05 % 6T (0 to100 % 6T)
0.001 Abs (0 to 0.5 Abs)
0.002 Abs (0.5 to 1.0 Abs)
- - Imported silicon photodiode - - ± 0.0004 A/h @ 500 nm USB drive, USB host, RS232 - - ± 0.0004 - - - - - - - - - - - - -
LUS-B15 - - - - - - - - - ≤ 0.05 % T ± 0.5 % T Silicon photo diode Xenon and Deuterium lamp - - - - - - 25 kg - - AC 220 / 50 Hz or AC 110 / 60 Hz - - - - - - - - -
LUS-B10 190 to 1100 nm - 1.8 nm ±0.3 nm ≤0.1 nm - T, A, C, E ±0.3% τ (0 to 100%τ) ± 0.002 A (0 to 0.5 A) ± 0.003 A (0.5 A to 1 A) 0.15% τ (0 to 100% τ) ± 0.001 A (0 to 0.5 A) ± 0.0015 A (0.5 A to 1 A) - - Silicon photodiode Tungsten lamp, Deuterium lamp ≤0.03% τ (220 nm NaI, 340 nm NaNO2) 0.0005 A/h @500 nm - - - ± 0.002 A @500 nm - - 28 kg - - - - - ± 0.001 A - - - -
LUS-B13 190 to 1100 nm - 1.0 nm ±0.3 nm ≤0.1 nm - T, A, C, E ±0.3% τ (0 to 100%τ) ± 0.002 A (0 to 0.5 A) ± 0.003 A (0.5 A to 1 A) 0.15% τ (0 to 100% τ) ± 0.001 A (0 to 0.5 A) ± 0.0015 A (0.5 A to 1 A) - - Silicon photodiode Tungsten lamp, Deuterium lamp ≤0.03% τ (220 nm NaI, 340 nm NaNO2) 0.0005 A/h @500 nm - - - ± 0.002 A @500 nm - - 28 kg - - - - - ± 0.001 A - - - -
LUS-B11 - - - - - - - - - - - Silicon photodiode - - ± 0.001 A/h @ 500nm - - - ± 0.0005 A/h 30 kg - - - - - - - ±0.001A/h - - - -
LUS-B20 - - - - - - - - - ±0.3 %T 0.1 % T Silicon photodiode detector Deuterium lamp, Tungsten lamp (20 W/12 V) - - - - - - - - - 200 W - - - - - - - - -
LUS-B12 190 to 1100 nm - 1.8 nm ±0.3 nm 0.2 nm - - - - - - - Tungsten lamp, Deuterium lamp ≤0.05% T @ 220 nm, 360 nm - - - - - - 26 kg 17 kg - - - - ≤0.0005 Abs / half hour (after warm-up at 500 nm) ≤±0.001 Abs - - - -
LUS-B17 190 to 1100 nm - - ± 0.3 nm 0.2 nm - T, A, C, E ± 0.3% T 0 .15% T - - Import Silicon Photodiode Import Deuterium Lamp & Tungsten Halogen Lamp 50.05% r (220 nm Na l, 360nm NaN02) 0.001 A / h at 500 nm - AC 220V/50 Hz 11OV/60 Hz - - 28 Kg - - 120 W - - - - ± 0.001 A - - - -
LUS-B41 190 to 1100 nm - 1.8/1.0 nm ± 0.3 nm ≤ 0.2 nm 0 to 200%T, -0.3 to 3 A,0 to 9999 C - ± 0.002A (0 to 0.5 A), ± 0.003 A (0.5 to 1A), ± 0.3 % T (0 to 100 %T) ≤0.001A (0 to 0.5 A), ≤0.002A (0.5 to 1 A), ≤0.2%T (0 to 100% T) - - Silicon Photodiode - ≤ 0.05 % T (220/360 nm) ± 0.001A/H (500 nm,0 A) - - - ≤0.2 % T/3 min (250/500 nm 0%T), ≤0.3%T/3 min (250/500 nm 100%T) - 25 Kg 21 Kg - - - - - ± 0.001 A - - - -
LUS-B42 190nm to 1100nm - 0.5 to 6.0nm ± 0.3nm ≤ 0.1nm -0.00~200.0(%T), -4.0~4.0(A) - ±0.002Abs(0~0.5Abs)
± 0.004Abs(0.5~1.0Abs)
±0.3%T(0~100%T)
≤ 0.001Abs(0~0.5Abs)
≤ 0.002Abs(0.5~1.0Abs)
≤0.1%T(0~100%T)
- - Photocell - ≤ 0.03% (220nm, NaI;360nm, NaNO2) - - - - ≤0.1%T(100%T), ≤0.05%T(0%T), ≤±0.0005A/h (500nm,0Abs,2nm bandwidth) 18 Kg - - - - - - - - - - - -
LUS-B23 190 to 900nm - 4nm, 2nm, 1nm, 0.5nm, 0.2nm, 0.1nm ±0.1nm - - - - - - - Photomultiplier Tubes Imported Deuterium Lamp, Imported Tungsten Lamp ≤0.02% τ (220nm NaI,340nm NaNO2) 0.0005A/h(500nm After preheating) - - - ±0.0002A (500nm After preheating) 28Kg - - - - - - - ±0.001A - - - -
LUS-B43 190 to 1100nm - 2nm or 1nm ±0.3nm ≤ 0.1nm 0.0 to 200.0%T
-0.301 to 4.000A
0.000 to 9999C
- ±0.3%T
±0.002Abs (0 to 0.5A)
±0.004 Abs (0.5 to 1A)
≤ 0.15%T
0.001 Abs (0 to 0.5A)
0.002 Abs (0.5 to 1A)
- - Silicon photocell Deuterium Lamp, OSRAM Tungsten Lamp ≤ 0.02%T (at 220nm NaI, 360nm NaNo₂) - - - - - - 42.5 Kg 34 Kg - - - - - - - - - -

Most Viewed

Customer Enquiry Form

Ask Expert

Address: Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608

Copyright © 2024 Labtron Equipment Ltd. All rights reserved.