Labtron Dry-Bath Incubator maintains temperatures ranging from ambient to 160°C, offering contamination-free heating for sample incubation They are equipped with interchangeable blocks to accommodate wide range of tubes and plates. Their construction enhances durability, making them reliable for long-term use. They include integrated timer, allowing automated temperature adjustments without manual intervention. Our Dry-Bath Incubator is ideal for enzyme reactions, incubation and activation of cultures, DNA denaturation, coagulation studies, and sample preparation.
Temperature range: RT. 5°C ~ 160°C
Temperature accuracy: ± 0.5 °C at 40 °C ; ± 1 °C at 120°C
Temperature uniformity: ± 0.5 °C
Block quantity: 1 or 2
Temperature range: RT. 5°C ~ 130°C
Temperature accuracy: ± 0.5 °C at 40 °C ; ± 1 °C at 120°C
Temperature uniformity: ± 0.5 °C
Block quantity: 4
Temperature Control Range: RT+5°C to 150°C
Temperature Set Range: 0°C to 150°C
Block Quantity: 1
Heating Up Rate (20°C to 100°C): ≤10 min
Temperature Control Range: RT+5°C to 150°C
Temperature Set Range: 0°C to 150°C
Block Quantity: 2
Heating Up Rate (20°C to 100°C): ≤10 min
Temperature Control Range: RT+5℃ to 150℃
Temperature Set Range: 0℃ to 150℃
Block Quantity: 4
Heating Up Rate (20℃ to 100℃): ≤10 min
Temperature Control Range: RT+5℃ to 150℃
Temperature Set Range: 0℃ to 150℃
Block Quantity: 1
Heating Up Rate (20℃ to 100℃): ≤10 min
Temperature range: RT. 5°C ~ 100°C
Temperature accuracy: ≤ ± 0.3°C
Temperature uniformity: ≤ ± 0.3 °C
Temperature stability: ± 0.3°C
Temperature range: RT. 5°C ~ 100°C
Temperature setting range: 0 °C - 100 °C
Temperature accuracy: ≤ ± 0.3 °C
Temperature uniformity: ≤ ± 0.3 °C
Temperature Control Range: RT+5°C to 100°C
Temperature Set Range: 5°C to 100°C
Heating Up Rate: ≤15 min (20°C to 100°C)
Temperature control mode: Heating membrane
Temperature control range: RT. (-30) °C - 100°C
Temperature setting range: (-10) ℃ - 100 ℃
Temperature accuracy: ≤ ± 0.3 °C
Temperature uniformity: ≤ ± 0.3 °C
Temperature Control Range: RT-30°C to 100°C
Temperature Set Range: -10°C to 100°C
Temperature control mode: Semi-conductor
Cooling Down Rate: ≤30 min (from 25°C)
Temperature Range: RT+5 ℃ to 120 ℃
Temperature Setting Range: 25 ℃ to 120 ℃
Temperature Control Accuracy: ± 0.5 ℃
Temperature Uniformity At 37℃: ± 0.5 ℃
Temperature Control Range: RT+5°C to 105°C
Temperature Set Range: 0°C to 105°C
Heating Up Rate: ≤10 minutes (20°C to 100°C)
Temperature Stability @40°C: ±0.3°C
Address:Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom