Dual Flow Particle Counter LDPC-A10 has a dual flow system which operates at flow rates 2.83 L/min and 50 mL/min. Equipped with six channels to measure six size ranges simultaneously with real-time monitoring. Integrated data logging and computer connectivity makes documenting and analyzing results easier. It calculates the upper confidence limit to estimate the maximum particle concentration, crucial for quality control and meeting regulations.
Request QuoteFlow Rates |
2.83 L/min 50 mL/min |
Particle Size Channels |
0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm 0.3 µm, 0.5 µm, 1.0 µm, 2.0 µm, 3.0 µm, 5.0 µm |
Sensitivity | 0.3 µm |
Test Class | Class 100 to Class 300,000 |
Test Period | 1 min to 10 min (10 levels) |
Life of Light Source | ˃ 30,000 Hours |
Self-clean Time | ≤ 10 min |
Operating Temperature Range | 10 ℃ to 35℃ |
Operational Humidity | ≤ 75 % RH |
Power Consumption | 15 W |
Power | 220 V ± 10 %, 50 Hz ± 2 Hz |
Dimension | 215 × 255 × 110 mm |
Weight | 2.6 Kgs |
Dual Flow Particle Counters are used in industries like pharmaceuticals, electronics, manufacturing, and healthcare to monitor and ensure cleanroom cleanliness by measuring airborne particles.
Download catalog for
Dual Flow Particle Counter LDPC-A10
Download manual for
Dual Flow Particle Counter LDPC-A10
Our LDPC-A10 features six separate channels, each capable of measuring different particle size intervals (0.3 µm, 0.5 µm, 1.0 µm, 3.0 µm, 5.0 µm, 10.0 µm), allowing for in-depth tracking of particles in the air as they occur.
Determining the highest possible certainty range in our LDPC-A10 is vital for predicting the highest possible amount of particles, which is key for maintaining quality standards and adhering to legal requirements, guaranteeing the sterility of cleanroom settings.
Our LDPC-A10 has a large data storage capacity, allowing it to store extensive monitoring data for future reference and analysis. This feature ensures comprehensive documentation of air quality measurements over time.
An instrument that can function at two distinct flow rates while sampling particles is called a dual-flow airborne particle counter. This makes it possible to measure the concentrations of airborne particles in a larger range of settings and circumstances with more flexibility.
Air is drawn through two distinct detecting chambers, each with a different flow rate, for dual-flow airborne particle counters to function. This makes it possible to simultaneously measure particles at two distinct flow speeds. Usually, the counts from every flow path are shown independently.
They find usage in several sectors, including research laboratories, cleanrooms, pharmaceutical manufacturing, semiconductor production, HVAC system monitoring, environmental monitoring, and environments where accurate control and tracking of particulate matter are crucial.
To guarantee accuracy and dependability, routine maintenance and calibration are necessary. This includes testing and replacing filters as needed, cleaning optical components regularly, and maintaining equipment per manufacturer instructions.
The advantages include more flexibility in the examination of particle size, increased precision through dual flow sampling, extensive data management features, and the ease of on-site printing and computer interface for data analysis and transmission.
Post your question?
Our experts are here to help!
Address: Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608