info@labtron.com +44 2080 043608
Fluorometer-LFFM-A11

Fluorometer-LFFM-A11

Fluorometer LFFM-A11 is the next generation of benchtop dual-channel Fluorometer, features 460 ± 20 nm and 625 ± 20 nm excitation filter and measures dsDNA concentration with high sensitivity lower DNA detection limit of 0.5 ng/ul. It offers blue and red channel fluorescence to measure fluorescence intensity of fluorescent reagent that combines with target molecule to read concentration of sample. Designed to accurately detect high-sensitive fluorescence while quantifying DNA, RNA, and protein.

Request Quote
Dynamic range Five orders of magnitude
Linear dynamic range R2 >0.995
Processing time 3s (Once)
Light source Blue LED Red LED
Excitation filters 460 ± 20 nm 625 ± 20 nm
Emission filters 525 to 570 nm (45 nm) 670 to 725 nm (55 nm)
Detector Photodiode
Repeatability <1.5 %
Stability <1.5 %
Sensitivity ds DNA: 0.5 ng/ml
Dimension 194 × 155 × 72.5 mm
Weight 0.4 kg
  • Designed with 4.3 inch touch screen, small and easy to use
  • Easy measurement within 3 sec for DNA, RNA, and protein
  • High sensitivity lowest DNA detection limit is 0.5 pg/ul
  • Linear dynamic range with five orders of magnitude
  • Equipped with two fluorescence channels for nucleic acid, protein quantitation in one detection
  • Offers opening system
  • Adopts PCR tube adapter
  • It can save at most 1,000 data and output data by USB port

Fluorometer is used for processing scarce and difficult samples, for low quantity of DNA, RNA, or protein after extraction, also, in expensive experiments: q PCR, PCR cloning, transfection, the next generation sequencing and etc. Applied for Nucleic acid quantification, Plant GUS reporter gene detection, Apoptosis detection.

Accessories no.Name
1Adapter for 0.5ml qPCR tube

Accessories no.Name
1Adapter for 0.2ml qPCR tube

Compare Models

Model Dynamic range Linear dynamic range Processing time Light source Excitation filters Emission filters Detector Repeatability Stability Sensitivity Dimension Weight
LFFM-A10 Five orders of magnitude R2 >0.995 3s (Once) UV LED Blue LED 365 ± 20 nm 460 ± 20 nm 420 to 480 nm (60 nm) 525 to 570 nm (45 nm) Photodiode <1.5 % <1.5 % ds DNA: 0.5 ng/ml 194 × 155 × 72.5 mm 0.4 kg
LFFM-A11 Five orders of magnitude R2 >0.995 3s (Once) Blue LED Red LED 460 ± 20 nm 625 ± 20 nm 525 to 570 nm (45 nm) 670 to 725 nm (55 nm) Photodiode <1.5 % <1.5 % ds DNA: 0.5 ng/ml 194 × 155 × 72.5 mm 0.4 kg
LFFM-A12 Five orders of magnitude R2 >0.995 3s (Once) Blue LED Green LED 460 ± 20 nm 525 ± 20 nm 525 to 570 nm (45 nm) 575 to 640 nm (65 nm) Photodiode <1.5 % <1.5 % ds DNA: 0.5 ng/ml 194 × 155 × 72.5 mm 0.4 kg

Most Viewed

Customer Enquiry Form

Ask Expert

Address: Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608

Copyright © 2024 Labtron Equipment Ltd. All rights reserved.