Request A Quote
Hematology Analyzer LHTA-B10

Hematology Analyzer LHTA-B10

Hematology Analyzer LHTA-B10 can process up to 60 samples per hour. It requires only 12μl for whole blood and 20μl for pre-diluted blood samples for testing. Offers an analysis of 21 parameters along with 3 histograms. Featuring a 9.7-inch color touch LCD screen for easy operation and display of all parameters and histograms. It automatically cleans the sampler, counting pool, and pipeline after starting up. Our Hematology analyzer utilizes the electrical impedance method and provides cyanide-free detection of HGB.
Request Quote
Throughput 60 samples/hour
Channels 2
Histograms 3 histograms (including WBC, RBC, PLT histograms)
Sample Volume Whole blood: 12 µl
Pre-diluted: 20 µl
Calibration Manual, auto-calibration
Counting Modes Venous, capillary, pre-diluted
Printing Model Auto print, manual print
Principle Impedance for WBC differentiation and WBC/RBC/PLT count; Colorimetric method for HGB
Parameters 21 parameters (including WBC, Mid%, Lym%, Gran%, Mid%, Lym%, Gran%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PDW, PCT, LCR, P-LCC)
LIS Interface Support Bi-Directional LIS
Language English, Spanish, French, Russian, Ukrainian
Reagent Diluent 10L, Hemolytic agent 250 ml, Probe cleanser 50 ml
Data Input 9.7-inch touch screen, mouse, keyboard (optional)
Output Internal printer, support external printer
Printer Paper Size 57 × 30mm
Interface 4 USB ports, network port, RS232 serial port
Storage 100,000 results with histogram
Unclog High voltage burns, reverse high-pressure flush
Working Temperature 15℃ to 30 ℃
Relative Humidity Range 30% to 85%
Atmospheric Pressure Range 70.0 kPa to 106.0 kPa
Carry-Over Rate WBC: ≤ 1.5%
RBC: ≤ 1%
HGB: ≤ 1%
PLT: ≤ 3%
Background WBC ≤ 0.3× 10⁹/L
RBC ≤ 0.03 × 10¹²/L
HGB ≤ 1g/L
HCT ≤ 5.0%
PLT≤ 10×10⁹ /L
Linearity
Parameter Measurement Range CV
WBC (0.5~10.00×10⁹)/L, (10.10~99.9×10⁹)/L (±0.5×10⁹)/L, ±5%
RBC (0.05~1.00×10¹²)/L, (1.01~9.99×10¹²)/L (±0.05×10¹²)/L, ±5%
HGB (2~70g)/L, (71~300.0g)/L (±2.0g)/L, ±2%
PLT (10~100×10⁹)/L, (101~999×10⁹)/L (±10.0×10⁹)/L, ±8%
Precision
Parameter Repeatability Measurement range
WBC ≤ 6.0% (3.5 to 9.5 × 10⁹)/L
RBC ≤ 3.0% (3.8 to 5.8 × 10¹²)/L
HGB ≤ 2.5 % (115 to 175g)/L
PLT ≤ 10.0 % (125 to 350 × 10⁹)/L
HCT ≤ 3.0 % 35% to 50%
Power Supply 100-240 AC, 50/60Hz, 150VA
Reagent Dimension 340 × 340 × 340 mm
External Dimension (W×D × H) 295 × 467 × 418 mm
Packaging Dimension (W × D × H) 404 × 564 × 616 mm
Reagent Weight 13 Kg
Net Weight 19 Kg
Gross Weight 31 Kg
  • Built-in thermal printer
  • External printers can be connected
  • Operates 24 hours
  • Fully intelligent blockage removal
  • Alarm functions available
  • Automatic and manual calibration modes
  • Supports LIS system
Hematology analyzers provide detailed information on complete blood count (CBC) analysis and hemoglobin analysis. It is utilized across clinical laboratories, hematology clinics, veterinary medicine, pharmaceutical research, and biotechnology sectors.
Mouse × 1 piece
Touch pen × 1 piece
Waste barrel × 1 piece
Power adapter × 1 piece
RVV Power Cord × 1 piece
Earth wire × 1.5 m
thermal printing paper × 1 piece
Detector cleaning fluid × 1 bottle
Hematology analyzer lyse × 1 bottle
Hematology analyzer diluent × 1 bottle
Cap components for lyse × 1 Set
Cap components for diluent × 1 Set
Cap components for waste bottle × 1 Set
Key × 2 pieces
20L Diluent
500ML Lyse
50ML Detector Cleaning Fluid
2L Diluent
100MLE-Z Cleaning Fluid

Models of Hematology Analyzer

Labtron Hematology analyzers are capable of assessing a wide range of blood parameters, including RBC count, WBC count, platelet count, hemoglobin concentration, and more. These analyzers can process a large number of blood samples quickly and accurately, with their automation capability. Our hematology analyzer utilizes both the impedance method and a Cyanide-free technique for cell counting and hemoglobin measurement. They offer triple counting modes, including venous, capillary, and prediluted options. These analyzers adapt to diverse sample types and enhance flexibility in diagnostic procedures.

Hematology Analyzer LHTA-A10

Hematology Analyzer LHTA-A10

  • Measuring principle : Tri-angle laser scatter Flow cytometry method Impedance method for RBC and PLT counting Cyanide-free method for HGB test 3D Scattergram analysis
  • Parameters : 25 Reportable parameters: WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW-SD, RDW-CV, PLT, MPV, PCT, PDW, P-LCR, P-LCC, NEU%, LYM%, MON%, EOS%, BAS%, NEU#, LYM#, MON#, EOS#, BAS# 1 3D Scattergram 3 Histograms (WBC/BASO, RBC, PLT) 4 Research parameter: ALY%, ALY#, IG%, IG#
  • Test Mode : CBC mode, CBC+DIFF mode Venous whole blood, Capillary whole blood and Prediluted
  • Throughput : 60 tests/hour
Hematology Analyzer LHTA-C10

Hematology Analyzer LHTA-C10

  • Throughput : Whole blood: Up to 60 samples per hourPre-diluent: Up to 60 samples per hour
  • Sample Capacity : Whole blood: 20 µLPre-diluent: 20 µL
  • Parameters : WBC, LYM%, MON%, NEU%, EOS%, BAS%, LYM%, MON%, NEU%, EOS%, BAS%, RBC, HGB, HCT, MCV, MCH, MCHC, RDW_CV, RDW_SD, PLT, MPV, PDW, PCT, P_LCR, P_LCC, RETIC%, RETIC_ABS, IRF, ALY%, ALY%, LIC%, LIC%, NRBC%, NRBC%
  • Histograms : 2 for RBC and PLT
Hematology Analyzer LHTA-A11

Hematology Analyzer LHTA-A11

  • Automation : Semi-automatic
  • Measuring Principle : Electrical impedance, SFT method for Hemoglobin
  • Sample Volume : Venous whole blood: 9.6μL
  • Throughput : 60 tests/Hour (open sampling)

Hematology Analyzer:
Hematology Analyzer LHTA-A10, Hematology Analyzer LHTA-C10, Hematology Analyzer LHTA-A11, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us: