Hydrogen Peroxide Generator LVHG-A10

Hydrogen Peroxide Generator LVHG-A10

Hydrogen Peroxide Generator LVHG-A10 is specially designed device for sterilization in enclosed spaces such as isolation room, isolator, transfer passageway, blending machine, biosafety cabinets and in small clean room. It takes the advantages of the hydrogen peroxide has better sporicidal efficiency in gas state than the liquid state at room temperature and then generated free hydroxyl groups are this to attack cell components, including lipids, proteins and DNA organization, which achieves the requirement of complete sterilization.

Request Quote
Injection rate 0 to 4 g/min
Air flow for Sterilization ≤ 2.4 m3/min
Vaporization Temperature ≤ 100 °C
Humidity for Dehumidification ≤ 30 % RH
Sterilizing Space ≤ 503
Sterilizing Agent 35 % of food grade hydrogen peroxide solution
Capacity of Sterilizing Agent 500 g
Dehumidizer Molecular sieve
Sterilizing Ratio 106 for fat thermophilic spore
Working Mode Continuous
Ground Wire In effective connection with ground and ground impedance with no more than 4Ὼ
Environment Temperature 20°C to 40°C
Relative Humidity ≤ 70% RH
Compressed Air ≥ 0.4 MPa
Compressed Air Flow 36 L/min
Interface of Connected Air Air pipeline at 8
Noise ≤ 70 dB (A)
Dimension 560 × 720 × 1000 mm
Power Supply AC 220 V ± 22 V, frequency 50 Hz ± 1 Hz
Power Requirement 2500 W
  • Fast sterilization cycle, cost-effective
  • Hydrogen peroxide has excellent material compatibility for validation
  • Secure under the room temperature and atmospheric pressure
  • Connected to materials of imported silicone tube and aseptic bayonet
  • Designed by dehumidification function to adjust, control humidity and temperature
  • Adopts data online printing function with colour touch screen display
  • Stearothermophilus killing capability is 106 by broad-spectrum sterilization
  • Alarm function interface
  • Good compatibility of hydrogen peroxide and gas material

Hydrogen Peroxide Generator is applicable in hospitals, monitoring technologies and pharmaceutical companies, sterilize fungi, bacteria, viruses and spores.

Compare Models

Model Injection rate Air flow for Sterilization Vaporization Temperature Humidity for Dehumidification Sterilizing Space Sterilizing Agent Capacity of Sterilizing Agent Dehumidizer Sterilizing Ratio Working Mode Ground Wire Environment Temperature Relative Humidity Compressed Air Compressed Air Flow Interface of Connected Air Noise Dimension Power Supply Power Requirement
LVHG-A10 0 to 4 g/min ≤ 2.4 m3/min ≤ 100 °C ≤ 30 % RH ≤ 503 35 % of food grade hydrogen peroxide solution 500 g Molecular sieve 106 for fat thermophilic spore Continuous In effective connection with ground and ground impedance with no more than 4Ὼ 20°C to 40°C ≤ 70% RH ≥ 0.4 MPa 36 L/min Air pipeline at 8 ≤ 70 dB (A) 560 × 720 × 1000 mm AC 220 V ± 22 V, frequency 50 Hz ± 1 Hz 2500 W
LVHG-B10 - ≥ 80 m3/h - - - - - - - - - - 0 to 85% RH - - - - - - -