Kjeldahl Analyzer

Labtron Kjeldahl Analyzer is specialized for quantifying 0.1mg to 250mg of nitrogen content, present in organic samples. They utilize sulphuric acid and catalysts for digestion of matter which releases ammonia gas. Their automated system simplifies decomposition, distillation and titration process. They feature precise temperature control and digital titration for accurate and reproducible measurement. Our Kjeldahl Analyzer is applicable for soil testing, pharmaceuticals and in nutritional labeling.

Filter

Clear All

Kjeldahl Systems

Measuring Range

Analysis Time

Water Consumption in the Distillation Process

Sample Capacity

Kjeldahl Analyzer LKA-A10

Kjeldahl Analyzer LKA-A10

Measuring Range: 0.1 mg-200 mg N

Analysis Time: 5-10 min/sample

Water Consumption in the Distillation Process: 1.5 l/min

Sample Capacity: Solid : ≤ 5g/sample; Liquid: 20 ml/sample

Semi-Automatic Kjeldahl Analyzer LKA-A20

Semi-Automatic Kjeldahl Analyzer LKA-A20

Measuring Range: 0.1 mg-250 mg N

Analysis Time: 3-4 min/sample

Water Consumption in the Distillation Process: 1.2-3 l/min

Sample Capacity: Solid : ≤ 6g/sample; Liquid: 16 ml/sample

Semi-Automatic Kjeldahl Analyzer LKA-B10

Semi-Automatic Kjeldahl Analyzer LKA-B10

Measuring Range: 0.1 mg to 240 mg N

Recovery: ≥99.5%

Sample Capacity: Solid: ≤6 g/sample Liquid: ≤16 mL/sample

Distillation Speed: 3 to 6 min/sample

Fully-automatic Kjeldahl Analyzer LKA-C10
Fully-automatic Kjeldahl Analyzer LKA-C10

Measurement Range: 0.1 to 200 mgN

Function: Automatic test module of conventional Nitrogen

Recovery Rate: ≥ 99.5 %

Sample: Solid ≤ 5 g   liquid ≤ 25 ml

Fully-automatic Kjeldahl Analyzer LKA-C11
Fully-automatic Kjeldahl Analyzer LKA-C11

Measurement range: 0.1 to 240 mg N

Function: Distillation and titration function based on classic Kjeldahl nitrogen determination method

Recovery rate: ≥ 99.5%

Sample: Solid ≦ 5 g/sample, Liquid ≦ 20 mL/sample

Fully Automatic Kjeldahl Analyzer LKA-C12

Fully Automatic Kjeldahl Analyzer LKA-C12

Measuring Range: 0.1mg to 240mg N

Analysis Time: 3 to 8min/sample

Reproducibility: Average value relative error ±0.5%

Recovery: ≥ 99.5%

Fully Automatic Kjeldahl Analyzer LKA-C13

Fully Automatic Kjeldahl Analyzer LKA-C13

Measurement Range: 0.1 to 210mgN

Analysis Time: 4 to 6 min/ sample

Sample Capacity: Solid:

Cooling Water Temperature: < 18°C


Kjeldahl Analyzer :
Kjeldahl Analyzer LKA-A10, Semi-Automatic Kjeldahl Analyzer LKA-A20, Semi-Automatic Kjeldahl Analyzer LKA-B10, Fully-automatic Kjeldahl Analyzer LKA-C10, Fully-automatic Kjeldahl Analyzer LKA-C11, Fully Automatic Kjeldahl Analyzer LKA-C12, Fully Automatic Kjeldahl Analyzer LKA-C13, and more.

Quick Links : About Us, Contact Us, User Manuals, Career, Terms of Use, Policies, Sitemap, Gallery.

Need a Product

send details for best price quotation

Click
For

Address:Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608