Fully-automatic Kjeldahl Analyzer LKA-C10 conducts titration and distillation simultaneously so as to neutralize the ammonia gas released which enhance the test efficiency and avoid the overflow of ammonia. It stand with a measuring range from 0.1 to 200 mgN which gives a maximum recovery of ≥ 99.5 %. The operating ambient temperature of the device starts from 10 °C to 35 °C. 8.0-inch LCD touch screen is used to set the distillation time, the amount of diluent, acid liquor and alkali. Diaphragm pump is used to add reagent so that the injure caused by high pressure pump can be neglected. Wireless network modules is installed for realizing remote data transmission to test data processing and report printing.

Fully-automatic Kjeldahl Analyzer LKA-C10
Fully-automatic Kjeldahl Analyzer LKA-C10
Fully-automatic Kjeldahl Analyzer LKA-C10
Request Quote
Measurement Range 0.1 to 200 mgN
Function Automatic test module of conventional Nitrogen
Recovery Rate ≥ 99.5 %
Sample Solid ≤ 5 g   liquid ≤ 25 ml
Distillation Time 3 to 8 min / sample
Distillation Mode Conventional distillation mode
Distillation Power 375 W to 1500 W
Condensate Water Consumption ≥ 1.5 L / min
Titr1ation precision 1
Repeatability RSD ≤ 0.5 %
Stored record 5000
Automatic Function Automatic sample dilution, addition of acid and alkali, distillation, reaction cup emptying and cleaning; auto correction, calculation and printing. Several conventional methods are equipped.
Result Determination Determined by the terminal color
Safety Protection Function
1.Level alarm system
2.Flow sensor monitors the whole process with the flow velocity be adjusted freely.
3.Temperature measurement of distillate
4.Acid and alkali resistant polymer composite materials used for the cabinet
Optical sensor RGB programmable optical sensing technology
Display mode 8.0-inch LCD touch screen
Titration mode High-precision micro-metering pump
Way of distillation Distillation and titration are carried out simultaneously
Steam flow Adjustable
Operating Ambient Temperature 10 °C to 35 °C
Language English
Power AC 220 V AC ± 10 % 50 Hz
Rated Power 1500 W
External Dimension 360×460×680 mm
Communication Mode (Enhancement Mode) Network Interface RS232 interface / USB interface
Weight About 20 kg
  • Ammonia gas released is neutralized to avoid the overflow of ammonia gas and it enhance the test efficiency
  • For improving precision and reducing cleaning work, traditional syringe plunger pump is replaced by a high-precision micro-metering pump
  • Imported RGB color sensor technology eliminates the disturbance of ambient light and an accurate judgment
  • Digestion duct, makes it more convenient for users to operate
  • To neglect the injure caused by high pressure pump, diaphragm pump is used to add reagent
  • 8.0-inch LCD touch screen to set the distillation time, the amount of diluent, acid liquor and alkali
  • Wireless network modules for remote data transmission, data processing and report printing
  • ARM processor with built-in Flash chip and equipped with a file system, enables user to create or delete folders or files and store 1000 routine data
  • All-stage warning system is installed which alters users for any abnormal working condition at any time
  • Real-time display of titration curve, informs the user about the working condition at any time
  • Built-in mini printer; to print experimental data according to their need

Fully-automatic Kjeldahl Analyzer is widely used in many applications such as determination of ammonia nitrogen, protein determination, nitrogen content, nitric nitrogen, phenols, volatile acids, cyanides, alcohol content and so on.

Fully-automatic Kjeldahl Analyzer LKA-C10 Banner
Fully-automatic Kjeldahl Analyzer LKA-C10 Banner

Models of Kjeldahl Analyzer

Labtron Kjeldahl Analyzer is specialized for quantifying 0.1mg to 250mg of nitrogen content, present in organic samples. They utilize sulphuric acid and catalysts for digestion of matter which releases ammonia gas. Their automated system simplifies decomposition, distillation and titration process. They feature precise temperature control and digital titration for accurate and reproducible measurement. Our Kjeldahl Analyzer is applicable for soil testing, pharmaceuticals and in nutritional labeling.

Fully Automatic Kjeldahl Analyzer LKA-C13

Fully Automatic Kjeldahl Analyzer LKA-C13

  • Measurement Range : 0.1 to 210mgN
  • Analysis Time : 4 to 6 min/ sample
  • Sample Capacity : Solid:
  • Cooling Water Temperature : < 18°C
Semi-Automatic Kjeldahl Analyzer LKA-B10

Semi-Automatic Kjeldahl Analyzer LKA-B10

  • Measuring Range : 0.1 mg to 240 mg N
  • Recovery : ≥99.5%
  • Sample Capacity : Solid: ≤6 g/sample Liquid: ≤16 mL/sample
  • Distillation Speed : 3 to 6 min/sample
Fully Automatic Kjeldahl Analyzer LKA-C12

Fully Automatic Kjeldahl Analyzer LKA-C12

  • Measuring Range : 0.1mg to 240mg N
  • Analysis Time : 3 to 8min/sample
  • Reproducibility : Average value relative error ±0.5%
  • Recovery : ≥ 99.5%
Fully-automatic Kjeldahl Analyzer LKA-C11
Fully-automatic Kjeldahl Analyzer LKA-C11
  • Measurement range : 0.1 to 240 mg N
  • Function : Distillation and titration function based on classic Kjeldahl nitrogen determination method
  • Recovery rate : ≥ 99.5%
  • Sample : Solid ≦ 5 g/sample,Liquid ≦ 20 mL/sample
Semi-Automatic Kjeldahl Analyzer LKA-A20
Semi-Automatic Kjeldahl Analyzer LKA-A20
  • Measuring Range : 0.1 mg-250 mg N
  • Analysis Time : 3-4 min/sample
  • Water Consumption in the Distillation Process : 1.2-3 l/min
  • Sample Capacity : Solid : ≤ 6g/sample; Liquid: 16 ml/sample
Kjeldahl Analyzer LKA-A10

Kjeldahl Analyzer LKA-A10

  • Measuring Range : 0.1 mg-200 mg N
  • Analysis Time : 5-10 min/sample
  • Water Consumption in the Distillation Process : 1.5 l/min
  • Sample Capacity : Solid : ≤ 5g/sample; Liquid: 20 ml/sample
Kjeldahl Analyzer LKA-D10

Kjeldahl Analyzer LKA-D10

  • Working Mode : Automatic and manual (without titration)
  • Measurement Range : 0.1 mgN to 200 mgN (Nitrogen content 0.1% to 99%)
  • Recovery Rate : ≥99% (relative error, includes digestion process)
  • Water Intake Method : Tap water and distilled water

Kjeldahl Analyzer:
Fully Automatic Kjeldahl Analyzer LKA-C13, Semi-Automatic Kjeldahl Analyzer LKA-B10, Fully Automatic Kjeldahl Analyzer LKA-C12, Fully-automatic Kjeldahl Analyzer LKA-C11, Semi-Automatic Kjeldahl Analyzer LKA-A20, Kjeldahl Analyzer LKA-A10, Kjeldahl Analyzer LKA-D10, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 73 4441 2688

Phone: +44 2080 043608

Follow us:

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 73 4441 2688 Phone: +44 2080 043608

Copyright © 2026 Labtron Equipment Ltd. All rights reserved.