We offer a varied range of high quality and durable pipette and pipette tips for maximal accuracy and precision. The universal design offer a level of compatibility and functionalities for end user convenience. The pipettes and pipette tips are designed taking into consideration every user's need and precised mode of application. The processing and packaging provide highest level of liquid handling equipment performance.
Pipette tip volume : 200 µL
Pack size : 96 holes
Color : Green
Autoclavable : Yes
Pipette tip volume : 1000 µL
Pack size : 96 holes
Color : Purple
Autoclavable : Yes
Test Volume : 5 μL
Accuracy error : 1.3 %
Precision error : 1.2 %
Test Volume : 10 μL
Accuracy error : 0.8 %
Precision error : 0.8 %
Test Volume : 20 μL
Accuracy error : 0.6 %
Precision error : 0.5 %
Test Volume : 25 μL
Accuracy error : 0.5 %
Precision error : 0.3 %
Test Volume : 50 μL
Accuracy error : 0.5 %
Precision error : 0.3 %
Test Volume : 100 μL
Accuracy error : 0.5 %
Precision error : 0.3 %
Test Volume : 200 μL
Accuracy error : 0.4 %
Precision error : 0.2 %
Test Volume : 250 μL
Accuracy error : 0.4 %
Precision error : 0.2 %
Test Volume : 500 μL
Accuracy error : 0.3 %
Precision error : 0.2 %
Test Volume : 1000 μL
Accuracy error : 0.3 %
Precision error : 0.2 %
Test Volume : 2000 μL
Accuracy error : 0.3 %
Precision error : 0.15 %
Test Volume : 5000 μL
Accuracy error : 0.3 %
Precision error : 0.15 %
Volume Range : 0.5 – 10 μL
Increment : 0.01 μL
Test Volume : 10 μL
Accuracy Error : ±1.00 %
Volume Range : 5 – 50 μL
Increment : 0.1 μL
Test Volume : 50 μL
Accuracy Error : ±0.80 %
Volume Range : 30 – 300 μL
Increment : 1 μL
Test Volume : 300 μL
Accuracy Error : ±0.60 %
Volume Range : 100 - 1000 μL
Increment : 5 μL
Test Volume : 1000 μL
Accuracy Error : ±0.60 %
Volume Range : 0.1 - 2.5 μL
Increment : 0.05 μL
Test Volume : 2.5 μL
Accuracy error : 2.50 %
Volume Range : 0.5 - 10 μL
Increment : 0.1 μL
Test Volume : 10 μL
Accuracy error : 1.00 %
Volume Range : 2 - 20 μL
Increment : 0.5 μL
Test Volume : 20 μL
Accuracy error : 0.90 %
Volume Range : 5 - 50 μL
Increment : 0.5 μL
Test Volume : 50 μL
Accuracy error : 0.60 %
Volume Range : 10 - 100 μL
Increment : 1 μL
Test Volume : 100 μL
Accuracy error : 0.80 %
Volume Range : 20 - 200 μL
Increment : 1 μL
Test Volume : 200 μL
Accuracy error : 0.60 %
Volume Range : 50 - 200μL
Increment : 1 μL
Test Volume : 200 μL
Accuracy error : 0.60 %
Volume Range : 100 - 1000μL
Increment : 5 μL
Test Volume : 1000 μL
Accuracy error : 0.60 %
Volume Range : 200 - 1000μL
Increment : 5 μL
Test Volume : 1000 μL
Accuracy error : 0.60 %
Volume Range : 1000 - 5000 μL
Increment : 50 μL
Test Volume : 5000 μL
Accuracy error : 0.50 %
No of Channels : 8
Volume Range : 0.5 -10 μL
Increment : 0.1 μL
Test Volume : 10 μL
No of Channels : 8
Volume Range : 5-50 μL
Increment : 0.5 μL
Test Volume : 50 μL
No of Channels : 8
Volume Range : 50-300 μL
Increment : 5 μL
Test Volume : 300 μL
No of Channels : 12
Volume Range : 0.5-10 μL
Increment : 0.1 μL
Test Volume : 10 μL
No of Channels : 12
Volume Range : 5-50 μL
Increment : 0.5 μL
Test Volume : 50 μL
No of Channels : 12
Volume Range : 50-300 μL
Increment : 5 μL
Test Volume : 300 μL
No of Channels : 8
Volume Range : 0.5 -10 μL
Increment : 0.1 μL
Test Volume : 10 μL
No of Channels : 8
Volume Range : 5-50 μL
Increment : 0.5 μL
Test Volume : 50 μL
No of Channels : 8
Volume Range : 50-300 μL
Increment : 5 μL
Test Volume : 300 μL
No of Channels : 12
Volume Range : 0.5-10 μL
Increment : 0.1 μL
Test Volume : 10 μL
No of Channels : 12
Volume Range : 5-50 μL
Increment : 0.5 μL
Test Volume : 50 μL
No of Channels : 12
Volume Range : 50-300 μL
Increment : 5 μL
Test Volume : 300 μL
Volume Range : 0.1 - 2.5 μL
Increment : 0.05 μL
Test Volume : 2.5 μL
Accuracy error : 2.50 %
Volume Range : 0.5 - 10 μL
Increment : 0.1 μL
Test Volume : 10 μL
Accuracy error : 1.00 %
Volume Range : 2 - 20 μL
Increment : 0.5 μL
Test Volume : 20 μL
Accuracy error : 0.90 %
Volume Range : 5 - 50 μL
Increment : 0.5 μL
Test Volume : 50 μL
Accuracy error : 0.60 %
Volume Range : 10 - 100 μL
Increment : 1 μL
Test Volume : 100 μL
Accuracy error : 0.80 %
Volume Range : 20 - 200 μL
Increment : 1 μL
Test Volume : 200 μL
Accuracy error : 0.60 %
Volume Range : 50 - 200μL
Increment : 1 μL
Test Volume : 200 μL
Accuracy error : 0.60 %
Volume Range : 100 - 1000μL
Increment : 5 μL
Test Volume : 1000 μL
Accuracy error : 0.60 %
Volume Range : 200 - 1000μL
Increment : 5 μL
Test Volume : 1000 μL
Accuracy error : 0.60 %
Volume Range : 1000 - 5000 μL
Increment : 50 μL
Test Volume : 5000 μL
Accuracy error : 0.50 %
Volume Range : 2 - 10 mL
Increment : 0.1 mL
Test Volume : 10 mL
Accuracy error : 0.60 %
Capacity : 10 mL
Color : Green
Packaging : Bulk Packing
Quantity Per Case : 100
Aspiration speed : 25 ml < 7s
Dispensing speed : Motor/gravity
Aspiration/Dispensing speed : NA
Pipette type : Plastic and glass pipettes, Pasteur pipette
Aspiration speed : 25 ml < 5s
Dispensing speed : Motor/gravity
Aspiration/Dispensing speed : 8 shifts
Pipette type : Plastic and glass pipettes, Pasteur pipette