Nucleic Acid Extraction system LNES-B10 is fully automated compact system designed to efficiently isolate DNA and RNA from multiple sample types, including whole blood, tissue, cells, plants and viruses. This compact unit can process 32 samples up to 1000 µL in a single run making efficient use of laboratory bench space. The most significant advantage is the reliability of the isolated nucleic acid and the technology utilizes an ultra-thin polymer membrane for efficient capture of nucleic acids, allowing for isolation of high quality, high yield RNA or DNA.
Request Quote
Sample Capacity 32 samples
Processing Volume 20 to 1000 µl
Extraction Method Magnetic Beads
Extraction Time 15 to 60 mint
Storage >1000
Magnetic Bead Recovery ≥ 98%
Magnetic Rod Flux 4500 Gs
Temperature Range RT to 100°C
Extraction Difference Between Wells < 3%
Module Station 2
Oscillating Mixing Vertical Mixing, low, medium and high 3 gears adjustable
Disinfection Lamp 8W UV lamp
Illuminating Lamp 3.4W LED lamp
Operation Interface 10.1 inch capacitive touch screen
Barcode Scanning Function Optional external barcode scanner
Interface 2 USB port, optional LAN port
Contamination Control Class II HEPA filter
Power Supply AC 100 – 240V 50/60Hz
External Dimension (L×D×H) 450×440×532 mm
Package Size (W×D×H) 538×538×750 mm
Gross Weight 37 kg
  • Easy to use friendly user interface
  • Smart and intelligent display with 10.1 inch LCD touch screen
  • UV sterilization lamp for dis-infection purpose
  • High efficiency HEPA filter and auto safety door protection function
  • HEPA filter and UV lamp replacement alarm functions
  • High purity of product
  • Fully automated and easy to operate
  • Optimization of extraction process with professional extraction kit
  • Large capacity program
  • Constant temperature function to ensure best reaction speed during the purification process
  • Friendly operation interface
  • Portable, light-weight and durable
  • Versatile liquid handling options
  • Built-in touch screen
These devices are used in various fields such as, Genetic Screening, Transgene Screening, Paternity Testing, Forensic Testing, Microbiology Testing, Plant molecular biology research and also for Genomic DNA and RNA extraction from whole blood, tissues, and cultured cells etc.

Models of Nucleic Acid Extraction System

Labtron Nucleic Acid Extraction System offer highly versatile magnetic-particle processing for high-throughput extraction. They efficiently isolate nucleic acid from whole blood, tissue, cells, plants, and viruses. The Extractor features a constant temperature function for optimal reaction speed and an extraction kit for reliable results. They have a user-friendly touchscreen, a built-in UV lamp, and ample data storage capacity. Our durable Nucleic Acid Extraction System is ideal for applications in diagnostic kits and research laboratories.

Nucleic Acid Extraction System LNES-B30

Nucleic Acid Extraction System LNES-B30

  • Sample Capacity : 16
  • Sample Volume : 200 to 1200 µl
  • Elution Volume : 60 µl/ 100 µl/ 150 µl/ 200 µl/ 300 µl
  • Processing Time : 30 to 70 min
Nucleic Acid Extraction System LNES-B21

Nucleic Acid Extraction System LNES-B21

  • Sample Capacity : 32 samples
  • Sample Volume : 20 µl to 1000 µl
  • Temperature Control Range : Room temperature +5℃ to 125℃
  • Extraction Method : Magnetic rod
Nucleic Acid Extraction System LNES-B20

Nucleic Acid Extraction System LNES-B20

  • Sample Volume : 20 µl to1000 µl
  • Sample Capacity : 16 samples
  • Extraction Difference Between Wells : CV ≤ 5%
  • Temperature Control Range : Room temperature to 120℃
Nucleic Acid Extraction System LNES-A13
Nucleic Acid Extraction System LNES-A13
  • Sample Capacity : 1 to 96
  • Sample Volume : 20 µl to 1000 µl
  • Extraction Time : 15 to 40 mints
  • Extraction Method : Magnetic Bead Recovery
Nucleic Acid Extraction System LNES-B22
Nucleic Acid Extraction System LNES-B22
  • Capacity : 96 samples
  • Sample Volume : 20 Sample to1000 µl
  • Recommended Volume : 200 to 400 µl
  • Extraction Difference Between Wells : ≤ 1%
Nucleic Acid Extraction System LNES-B23

Nucleic Acid Extraction System LNES-B23

  • Sample Capacity : 96 samples
  • Sample Volume : 20 to1000 µl
  • Recommended Volume : 200 to 400 µl
  • Extraction Difference Between Wells : ≤ 1%
Nucleic Acid Extraction System LNES-A10

Nucleic Acid Extraction System LNES-A10

  • Sample Capacity : 1 to 8 samples
  • Sample Volume : 20 to 500 µl
  • Working Volume : 200 to 1000 µl
  • Extraction Time : 15 to 40 minutes
Nucleic Acid Extraction System LNES-B11

Nucleic Acid Extraction System LNES-B11

  • Sample Capacity : 96 well
  • Sample Volume : 20 µl to 1000 µl
  • Extraction Time : 15 to 60 mints
  • Storage : >1000

Nucleic Acid Extraction System:
Nucleic Acid Extraction System LNES-B30, Nucleic Acid Extraction System LNES-B21, Nucleic Acid Extraction System LNES-B20, Nucleic Acid Extraction System LNES-A13, Nucleic Acid Extraction System LNES-B22, Nucleic Acid Extraction System LNES-B23, Nucleic Acid Extraction System LNES-A10, Nucleic Acid Extraction System LNES-B11, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 20 8004 3587

Phone: +44 2080 043608

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608

Copyright © 2025 Labtron Equipment Ltd. All rights reserved.