Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode : Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability : ≤ 0.1 within 30 min
Accuracy : Chromaticity co-ordinate 0.0001
Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm
System : D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source : D65 as illuminating source
Zero drift : ≤ 0.1 %
Sample (size) length : 38×70 mm
Measuring range : (1-500) mN.m (divided into 7 small ranges)
Indication error : 0.02
Test speed : (200° ± 20°)/ min
Sample (size) length : 90 to 200 mm
Sample width : 15 mm, 25 mm, 50mm
Measuring range : 0 to 30, 0 to 100 N,0 to 300 N
Accuracy : ± 1 %
Sample (size) length : 180 mm (180, 150, 100, 90, 50 mm adjustable)
Sample width : 15 mm
Measuring range : 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Accuracy : ± 1 %
Sample (size) length : 0 to 200 mm adjustable
Sample width : 15 mm
Measuring range : 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Accuracy : ± 1 %
Measurement range : 0 to 100° SR
Sealed testing speed : 100 ± 10 mm/s
Volume of distilled water : 1000 ± 5 ml
Draining time : 149 ± 1 s
Measurement range : 0 to 200 mm
Specimen size : 15×250 mm
Division value : 1 mm
Number of specimen holders : 5
Metal Cylinder inner area : (100 ± 0.2) cm2
Metal Cylinder height : 50 mm
Metal roller width : (200 ± 0..5) mm
Metal roller weight : (10 ± 0.5) kg
Sample diameter : 125 mm
Sample error : ± 0.2 mm
Sample Thickness : 0.1 to 1.0 mm
Dimension : 240×288×435 mm
Measurement range : 0.01 to 10 N
Slider weight : 200 g
Slider size : 63×63 mm
Testing accuracy : ± 2 %
Testing speed : 200° ± 20° / min
Test range : 1 to 10000 mN
Indicating Error : ± 1 %
Testing length : 5, 10, 15, 20, 25, 50 mm
Measuring range : 0 to 4 mm
Accuracy : 0.01 or 0.001 mm
Gauge : Analogue gauge display
Contact pressure (to create false weight) : 100 ± 10 kPa
Measuring range : 0 to 20 mm
Accuracy : 0.01 mm
Gauge : Analogue gauge display
Contact pressure (to create false weight) : 20 ± 0.5 kPa
Measuring range : 0 to 5 mm
Division value : 0.001 mm
Measuring parallelism : ≤ 0.002 mm
Indication error : ± 0.0025 mm or ± 0.5 %
Sample size (L*B) : 230×50 mm (can join short samples together)
Rub pressure : 20 ± 0.2 N
Friction speed : 43 times / min
Friction area (L*B) : 155×50 mm
Sample width : 15 mm
Sample maximum length : 300 mm
Parallelism : ≤ 0.1 mm
Dimension : 240×520×70 mm
Measuring range : 10 to 1000 mN
Division value : 1 mN
Accuracy : ± 1%
Indicating Error : ≤ 0.5
Measuring range : 0.1 to 10 kN
Indication error : < ± 1%
Platen Size : 500×500 mm (customized)
Operating stroke : 500 mm (customized)
Measuring range : 1 to 50 kN
Indication error : < ± 1%
Platen Size : 800×800 mm/ 1000×1000 mm/ 1200×1200 mm/ 1500×1500 mm (customized)
Operating stroke : 800 mm/ 1000 mm/ 1200 mm/ 1500 mm (customized)
Measuring range : 0 to 1000 ml/min
Test area : 10 ± 0.02 cm2
Area differential pressure : 1 ± 0.01 kPa
Inner diameter of grip ring : 35.68 ± 0.05 mm
Measuring Range : A file: 20 to 500 J/m² B file: 500 to 1000 J/m²
Specimen Size : 25.4mm × 25.4mm
Sample Clamping Force : 0 to 400N (adjustable)
Impact Angle : 90°
Measuring range : A (1 to 6) J indicating error ± 0.05 J B (1 to 12) J indicating error ± 0.05 J C (1 to 24) J indicating error ± 0.05 J D (1 to 48) J indicating error ± 0.05 J The indicating errors w.r.t measurement range of 20 to 80 %
Frictional resistance :
Pyramid dimension : Three sides: 60×60×60 mm, height 25 ± 0.7 mm, Arris edge fillet radius 1.5 ± 0.1 mm
Dimension : 800×470×840 mm
Measuring range : 0 to 1000 mN
Resolution : 0.1 mN
Indication error : ± 1 %
Tearing arm : 104 ± 1 mm
Capacity : 10 -16000 mN
Resolution : 0.1 mN
Tearing arm : 104 ± 1 mm
Tearing angle : 27.5° ± 5°
Measurement range : 0 to 5600 kPa
Accuracy : ± 0.5 % F.S.
Compression speed : 170 ± 15 ml/min
Clamp pressure : ≥ 690 kPa
Measurement range : 50 to 1600 kPa-paper and 50 to 5600 kPa-paper
Resolution : 0.01 kPa
Accuracy : ≤± 0.5 %
Compression speed : 95 ± 5 ml/min
Measurement range : 5 to 500 N, 50 to 3000 N
Resolution : 1 N
Accuracy : ± 1 %
Variability : ≤ 1 %
Measuring scope : ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s)
Accuracy : ±0.1 s within 300 s
Vacuum system volume (ml) : Bigger volume: 380 ± 1 Smaller volume: 38 ± 1
Contact pressure : 100 ± 2 kPa
Measuring scope : 0 to 99999 s
Folding angle : 135° ± 2°
Tensile scope : 4.9 to 14.7 N
Folding head suture size : 0.25 mm, 0.50 mm, 0.75 mm, 1.00 mm