Labtron particle size analyzers come in a variety of forms, including spray, nano, laser, and image models. These have a range of cutting-edge features and technology. They have auto optical path alignment, sensitive detectors, and semiconductor lasers. These analyzers measure a wide range of particle sizes with precision and reliability. We provide analyzers with advanced data analysis software, autonomous operating modes, and integrated dispersion units. Our particle size analyzers come with a variety of analytical modes, quick test times, and output formats for reporting and data interpretation.
Measuring range: 1μm to 6000 μm
Technology: Computer image analysis technology
Particle properties measured: Morphology & size
Particle shape parameters: Aspect ratio, sphericity, surface ratio, specific surface area, circumscribed rectangle parameters etc.
Measuring range: 2 μm to 6000 μm
Dispersion: Ultrasonic, Stirring, Circulation
CCD: High speed and resolution CCD (The shutter speed is 10-6/s)
Maximum resolution: 1028 × 1024
Measuring Range: 30μm to 5000μm
Dispersion: free fall
Maximum Resolution: 3000 × 2000
Executive Standard: ISO/DIS-13322-2
Dispersion Type: Wet
Measurement Range: 0.1 to 300 µm
Channel number: 39
Accuracy Error:
Dispersion Type: Wet
Measurement Range: 0.01 to 2000 µm
Channel number: 127
Accuracy Error:
Dispersion Type: Wet
Measurement Range: 0.1 to 1000 µm
Channel number: 90
Accuracy Error:
Dispersion Type: Wet
Measurement Range: 0.01 to 2000 µm
Channel number: 87
Accuracy Error:
Dispersion Type: Wet
Measurement Range: 0.01μm to 2000μm
Channel Number: 116
Accuracy Error:
Dispersion Type: Dry
Measurement Range: 0.1 to 2000 µm
Channel number: 100
Accuracy Error:
Dispersion Type: Dry
Measurement Range: 0.1 to 300 µm
Channel number: 40
Accuracy Error:
Dispersion Type: Wet and Dry
Measurement Range: Wet: 0.01 to 2000 µm Dry: 0.1 to 2000 µm
Photodetectors: Silicon photodetectors
Channel number: Wet: 127 Dry: 100
Dispersion Type: Wet and Dry
Measurement Range: Wet dispersion: 0.01 to 3600 µm Dry dispersion: 0.1 to 3600 µm
Detection Angle Range: 0.016° to 140°
Number of Detection Channels: 103
Measuring range: 1 nm-10000 nm
Principle: Dynamic light scattering & Brownian motion
Test speed: < 5 min
Sample type: Suspension, emulsion and powders
Measurement Range: 1 to 10000 nm (sample-dependent)
Zeta Potential Range: -500 mV to +500 mV
Test Speed: < 5 minutes
Concentration Range: 0.1 mg/mL to 100 mg/mL
Measuring range: 1 μm - 2000 μm
Principle: Fraunhofer light diffraction
Spray area range: 1 - 10 m
Structure: Split-type
Address:Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom