Labtron Petroleum Testing Equipment offer wide range of versatile testers with unparalleled efficiency and precision. They include calorimeters, analyzers, testers, and viscometers for quantifying variety of elements in different types of oil. Their easy-to-use interfaces and menus for setting parameters streamline testing operations. These testers ensure samples stay at the perfect temperature during testing. Our fast, reliable Petroleum Testing Equipment monitor trace element concentrations in petrochemicals.
Calorimeter type : Isoperibol
Temperature range : 5 to 40°C
Measurement range : 5 to 40 MJ/ kg
Operation Mode : The outer barrel temperature is constant
Measuring Range : 0 to 50000 J
Bomb Volume : 250 ml
Test Method : Isoperibol
Test Duration/ Sample : Test time
temperature range : 5℃ to 35℃
Temperature resolution : 0.0001℃
RSD (Relative standard deviation) : ≤40J/K
Test period : About 12 mins
Bomb Volume : 250 ml
Analysis Time : < 8 min full test process:
Bomb Washing : Manual
Maximum Bomb Pressure : 20 MPa
Calorimeter type : Isoperibol
Oxygen filling : Semi-automatic
Bomb volume : 282 ml
Analysis time : 15 to 25 min
Cetane Number Range : 0 to 100 (Typical testing CN range: 30 to 65)
Cast Iron Cylinder Bore (Diameter) : 82.55mm (3.250 inch)
Piston Stroke : 114.30mm (4.50 inch)
Compression Ratio Range : Adjustable 8:1 to 36:1 by external handwheel assembly
Test Liquids : Diesel, Gasoline
Measuring Range for Gasoline : Aviation gasoline: 86.0 to 105.0/MON Automobile gasoline: 50.0 to 115.0/RON
Measuring Range for Diesel : Automobile diesel oil: 25 to 75/CN
Measuring Accuracy : Aviation gasoline: ≤ ± 1.5/MON Automobile gasoline: ≤ ± 1.5/RON, ≤ ± 1.5/MON Automobile diesel oil: ≤ ± 2.5/CN, ≤ ± 2.5/CI Retest of regression samples: ≤ ± 0.5/RON, ≤ ± 0.5/MON Test of regression sample: ≤ ± 1.5/RON, ≤ ± 1.5/MON Calibration accuracy: ≤ ± 0.2/RON, ≤ ± 0.2/MON
Measurement item : motor gasoline and diesel
measurement unit of octane is ON : 40 to 120
Permissible error of octane : ± 0.5 max
Fluctuate range of octane : ± 0.2 max
Octane number range : 40 to 125 ON
Maximum error limit octane number : ±0.5 ON
Maximum parallel ON difference : ±0.2
Antiknock range : 0.5 to 15 %
Working Range : 40 to 120 Octane Number
Cast Iron Cylinder Bore (Diameter) : 82.55mm (3.250 inch)
Piston Stroke : 114.30mm (4.50 inch)
Cylinder Displacement : 0.61L (37.33 in³)
Ambient temperature : ≤ 35 °C
Relative humidity : ≤ 85 %
Precision of titration tube : Scale division is 0.02 ml
Total power consumption : ≤ 1200 W
Measurement range : ≥0.05 mg KOH/g
Potential measurement range : 0 to 1800.0 mV
Burette volume : 10 mL
Minimum titration volume : 0.001 ml
Volumetric analysis : Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.02 ml
Automatic acid titration : Titration condensation: 0.1 N; Controlling accuracy: ≤ ± 0.1 pH
Automatic potential control : Titration condensation: 0.1 N; Controlling accuracy: ≤ 10 mV
Ambient temperature : 0 ~ 35 ℃
Measurement Range : ≥ 0.001 Mg KOH/G
Potential Measurement Range : -2000.0 To 2000.0 Mv, 0.00 To 14.00PH
Burette Volume : 10ml
Minimum Titration Volume : 0.001ml
Graduated flask : 100 ml,50 ml
Conical flask : 100ml
Separatory funnel : 250ml
Ambient temperature : (-10 )°C to 35 °C
Measurement range : Room temperature ~ 150°C
Stirring speed : 0 ~ 1200 r / min
Heating power : 25 W
Interior Dimension : 360 × 250 × 545 mm
Temperature controlling accuracy : ≤ 0.5 ℃
Temperature controlling range : Room temperature ~ 200 ℃
Power supply for illumination : 5 V
Power of motor : 2 kW
Ambient Temperature : ≤ 40℃
Relative Humidity : ≤ 80 %
Measurement Range : Ambient to 300℃
Flash Point : Lower than 104℃, error is 2℃; Higher than 104℃, error is 6℃
Flash Point Determination Range : Ambient to 230℃
Accuracy : 0.1℃
Heating Rate : Procedure A: (5 to 6)℃/min Procedure B: (1 to 1.5)℃/min Procedure C: (3.0±0.5)℃/min
Stirring Rate : Procedure A and C: (90 to 120)RPM Procedure B: (250±10)RPM Automatic control and manually adjustable
Ambient Temperature : 10 ℃ to 35 ℃
Relative Humidity : < 85%
Ignition Mode : Electric Ignition
Cooling Method : Forced Air Cooling
Temperature Range : 0 ℃ to 60 ℃
Temperature Accuracy : ±0.5℃
Ambient Temperature : 15℃ to 35℃
Relative Humidity : ≤ 85%
Temperature Range : Ambient to 300 ℃
Temperature Resolution : 0.1 ℃
Procedure A Heating rate : 5 ℃ to 6℃/min
Procedure B Heating rate : 1 to 1.5 ℃/min
Measuring Range : 40 to 370℃ (104 to 698℉)
Resolution : 0.1℃
Heater Rate : Procedure A: 5℃/min to 6℃/min Procedure B: 1.0℃/min to 1.5℃/min Procedure C: 2.5℃/min to 3.5℃/min
Stirring Speed : Procedure A: 90r/min to 120r/min Procedure B: 250r/min ± 10r/min Procedure C: 90r/min to 120r/min
Stirring Speed : 1500 ± 15 rpm
Temperature Controlling Range : Room Temperature to 99.9℃
Temperature Controlling Accuracy : ±1℃
Ambient Temperature : Room Temperature to 35℃
Stirring Speed : 1500 ± 15 rpm
Ambient Temperature : RT to 35 °C
Relative Humidity : ≤ 85 %
Temperature Controlling Range : RT to 99.9 °C
Cubage of bath : Ф300 × 380 mm
Temperature controlling range : 0 °C ~ 100 °C
Temperature controlling accuracy : ± 0.2 °C
Temperature sensor : Industrial platinum resistance, Pt100
Temperature Range : Ambient to 100℃ (15℃ to 100℃ with optional chiller)
Temperature Accuracy : ±0.2℃
Bath Dimensions : Φ300×300mm
Cylinder Capacity : 500ml
Capacity of Cylinder : 500ml
Temperature Range : (Ambient +5) ℃ to 100℃
Temperature Accuracy : ±0.2℃
Temperature Sensor : Pt100
Temperature Range : AT to 400℃
Left Bath Temperature Range : 0 to 60℃, Accuracy: ±0.5℃
Right Bath Temperature Range : 0 to 60℃, Accuracy: ±0.5℃
Receiving Chamber Temperature Range : 0℃ to AT (Auto control)
Test Range : Temperature Range: 0~400℃ Accuracy: ±0.1℃ (PT100 Probe)
Receiving Chamber : Temp. Range: 0~60℃ (0℃ can be reached when AT is below 15℃) Accuracy: ±0.1℃
Condenser Bath : Peltier cooling Temp. Range: 0~60 ℃ (0℃ can be reached when AT is below 25℃) Accuracy: ± 0.1℃
Heating System : Low mass/low voltage heater Unique heating optimization system for fully automatic initial heat settings and heating regulation
Heating Power : 2 KW
Refrigeration Power : 0.5 KW
Standard : ASTM D86
Display : 10.4-inch large color touchscreen
Ambient temperature : -10°C to 35°C
Relative humidity : ≤ 85 %
Thermometer : Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
Scale division : 0.1 ℃
Graduated flasks : 100 ml
Distillation flask : 125 ml
Ambient temperature : ≤ 35 °C
Relative humidity : ≤ 85 %
Graduated flasks : 100 ml
Distillation flask : 125 mL
Ambient temperature : ≤ 30 °C
Relative humidity : ≤ 85 %
Graduated flasks : 100 ml
Scale division of graduated flask : 1ml
Distillation flask : 125 ml
Ambient temperature : ≤ 35 °C
Distillation flask : 125 mL
Ambient temperature : Room temperature to 35 °C
Relative humidity : ≤ 85 %
Thermometer : (-2 )°C to 300 ℃ and (-2) °C to 400 ℃
Graduated flasks : 10 ml and 100 ml
Scale division of graduated flask : 10 ml is 0.1 ml and 100 ml is 1 ml
Ambient temperature : (-10) °C ~ 35 °C
Relative humidity : ≤ 85 %
Graduated flasks : 100 ml
Scale division of graduated flask : 1 ml
Outer diameter of distillation flask : φ65
Refrigeration tube : φ14
Ambient temperature : 5 °C to 35 ℃
Relative humidity : ≤ 85 %
Cubage of buffer vessel : 1000 ml
Max. Residual pressure : ≤ 2 mm Hg
Evaporation tube specifications : 200 Φ mm
Evaporation tube heat transfer area : 0.4 m2
Built-in cooling area : 0.5 m2
Constant pressure feeding bottle : 3 L
Ambient temperature : ≤ 35 ℃
Relative humidity : ≤ 85 %
Heating power of electric furnace : 250 W × 2
Total power consumption : ≤ 700 W
Type : Oil bath
Capacity : 600 ml beaker
Grease cup Material : chrome-plated brass
Grease cup inner diameter : 9.92 mm
Graduated Flask : 200 ± 0.2 ml
Standard Water Value : 51 ± 1 s
Temperature Range : 0 ~ 100 °C
Temperature Controlling Accuracy : ± 0.2 °C
Graduated Flask : 100 ml
Standard Water Value : 51 ± 1 s
Temperature Range : 0 ~ 100 °C
Temperature Controlling Accuracy : ± 0.1 °C
Graduated Flask : 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)
Standard Water Value : 51 ± 1 s
Temperature Range : 0 ~ 100 °C
Ambient Temperature : 10 °C ~ 40 °C
Bath type : Oil bath
Bath capacity : 5000 ml ± 50 ml
Ambient temperature : Room temperature to 35 °C
Relative humidity : ≤ 85 %
Evaporation bath type and size : Aluminum block bath, φ260 × 130 mm
Holes for testing : 3 pieces
Size of holes for testing cylinder : φ51 × 70 mm
Flow rate display : Flow meter
Evaporation Bath Type : Aluminum bath
Evaporation Bath Size : φ260 × 130 mm
Testing Holes : 5 pieces
Testing Cylinder Hole Size : φ51 × 70 mm
Evaporation Bath : Solid metal block bath, 5 test positions
Bath Temperature : 160℃ to 165℃, automatic control, LCD display
Well Temperature : 150℃ to 160℃
Air Pressure : ≤ 35kPa
Temperature Range : 20℃ to 100℃ (external chiller required for ambient temperatures; high-temperature option up to 150°C available)
Temperature Accuracy : ±0.01℃
Timing Accuracy : 0.01s
Auto Sampler Capacity : 24 positions
Temperature Range : 20℃ to 100℃ (for temperatures around ambient, an external chiller is required)
Temperature Accuracy : ±0.01℃
Timing Accuracy : 0.02s
Auto Sampler Capacity : 12 positions
Ambient temperature : 15 to 35°C
Relative humidity : ≤ 85%
Capillary viscometer : 6 capillary Pinkevitch viscometer tubes
Stirring motor : 1200 rpm
Ambient temperature : -10°C to 35°C
Relative humidity : ≤ 85 %
Capillary viscometer : 11 pieces
Stirring motor : 6 W, 1200 rpm
Ambient temperature : -10°C to 35°C
Relative humidity : ≤ 85 %
Capillary viscometer : 11 pieces
Stirring motor : 6 W, 1200 rpm
Ambient temperature : -10°C to 35°C
Relative humidity : ≤ 85 %
Capillary viscometer : 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group
Stirring motor : 6 W, 1200 rpm
Ambient temperature : -10°C to 35°C
Relative humidity : ≤ 85 %
Capillary viscometer : 11 pieces
Stirring motor : 6 W, 1200 rpm
Ambient temperature : 0°C to 40°C
Relative humidity : 20 to 90 %, RH while 40℃
Temperature controlling accuracy : ± 0.1 °C
Barometric : 96 to 103 kPa
Temperature Range : -60℃ to 140℃
Temperature Accuracy : 0.05 ℃
Measurement : Kinematic Viscosity, Dynamic Viscosity, Density, Viscosity Index
Viscosity Range : 0.2 to 30,000 mm²/s
Temperature Range : Ambient to 100℃
Temperature Accuracy : ±0.01℃
Sample Capacity : 4
Bath Construction : Φ300×300mm glass vessel enclosed in Acrylic housing
Ambient temperature : ≤ 30 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 13 pieces
Stirring motor : 6 W, 1200 rpm
Temperature Range of Measuring Chamber : RT to -67°C
Temperature Accuracy : ± 0.1°C
Measuring Range : RT to -51°C
Measuring Accuracy : ± 0.1°C
Ambient temperature : ≤ 30 ℃
Refrigeration speed : > 40 °C / 10 min
Repeatability for solidifying point : ≤ 2 °C
Repeatability for pour point : ≤ 3 °C
Sample Volume : 4.5 ml
Sample Test Interval : 1°C
Temperature range : 51°C to -70°C
Repeatability : ±1°C
Ambient temperature : (-10)℃ ~ 35 ℃
Relative humidity : ≤ 85 %
Sample cup Inner diameter : 31.0 ~ 32.0 mm
Sample cup Wall thickness : 1.0 ~ 1.5 mm
Freezing Point Range : -54℃ to 2℃
Cold Bath Temperature Range : -70℃ to 30℃
Temperature Accuracy : ±0.1℃
Refrigerator System : Imported Refrigerator Compressor
Sample Freezing Point Range : 10℃ to -80℃
Sample Volume : 0.15 ml
Average Test Time : 10 to 20 min
Cold Bath Temperature Range : About 10 degrees lower than the test temperature
Cooling Bath Temperature Range : -80℃ to 20℃
Temperature Control Accuracy : 0.1℃
Display : 7-inch color LCD touchscreen
Stirring Method : Mechanical stirring (Adjustable Speed)
Sample Temperature Range : +20°C to -80°C
Test Resolution : 0.1°C
Temperature Accuracy : 0.1°C
Repeatability : 0.5°C
Refrigeration system : New-type refrigeration compressor
Controlling temperature of cold trough : Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C
Ambient temperature : ≤ 30 ℃
Relative humidity : ≤ 85 %
Chamber quantity : 2 chambers
Chamber 01 temperature control : Ambient to -51 ℃
Chamber 02 temperature control : Ambient to -65 ℃
Temperature precision : ±1°C
Refrigeration system : New-type refrigeration compressor
Controlling temperature of cold trough : Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
Ambient temperature : ≤ 30 ℃
Relative humidity : ≤ 85 %
Capacity : 20 L
Temperature range : Ambient +5°C to 100°C
Precision : ± 0.1℃
Stirring range : 1200 r/min
Temperature controlling accuracy : ± 0.5 °C
Refrigeration system : New-type refrigeration compressor
Cold trough : One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough : Room temperature ~ (-70) °C
Temperature controlling accuracy : ± 0.5 ℃
Refrigeration system : New-type refrigeration compressor
Cold trough : Two holes in one trough, and same temperature
Ambient temperature : ≤ 30 ℃
Temperature controlling accuracy : ± 0.5 °C
Refrigeration system : New-type refrigeration compressor
Cold trough : One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough : Room temperature ~ (-70) °C
Refrigeration System : New-type refrigeration compressor
Cold Trough : One trough with two baths, equal temperature in both
Controlling Temperature of Cold Trough : RT to -70°C
Ambient Temperature : ≤ 30°C
Temperature Range : 0℃ to -68℃
Temperature Accuracy : ±0.5℃
Test Cell : One
Test Wells : Two
Ambient Temperature : 10 ℃ ~ 40 °C
Relative Humidity : ≤ 80 %
Temperature Measurement- Full Scale : Ambient temperature to 300 °C
Temperature Measurement- Repeatability : ≤ 8 °C
Ambient Temperature : 10 ℃ ~ 40 ℃
Relative Humidity : ≤ 85 %
Temperature Measurement- Full Scale : Ambient temperature to ~ 400 ℃
Temperature Measurement- Repeatability : ≤ 4 ℃
Measuring Range : 79 to 370℃ (175 to 698℉)
Resolution : 0.1℃
Repeatability : ≤ 6℃
Reproducibility : ≤ 8℃
Flashpoint Determination Range : Ambient to 400℃
Repeatability : ≤ 8 ℃
Reproducibility : ≤ 17℃
Accuracy : 0.1℃
Thermometer : 0 ℃ ~ 360 °C
Scale Division : 1 °C
Ambient Temperature : ≤ 35 °C
Relative Humidity : ≤ 85 %
Temperature Control : 150.0°C ± 0.1°C; 140.0°C ± 0.1°C
Sample Size : 50g ± 0.5g
Wire Catalyst : Electrolytic copper wire conforming to ASTM D2272, D2112
Vessel Angle : 30°
Samples : 2
Oil bath cubage : 30 L
Angle between bomb and water surface : 30 °
Speed of rotary assembly : 100 ± 5 RPM
Temperature Range : RT to 150 ℃
Temperature Accuracy : ±0.1℃
Temperature Control : PID digital display temperature controller
Sample Volume : 5 g
Samples : 8
Temperature : 100 ℃
Temperature controlling accuracy : 0.1 ℃
Flow meter : 3 ± 0.3 L / H oxygen
Type : Compact; Desktop
Design : Integrated
Bath : Metal bath (without water usage)
Temperature control point of metal bath : 100℃ ± 1℃
Temperature Range : Ambient to 150℃
Temperature Precision : ± 0.1°C
Test Unit : 2 units
Heating Power : 1800 W
Temperature Range : 100℃ to 380℃
Temperature Accuracy : ± 1℃
Pressure Range : 0 to 340 mmHg
Pressure System : 500psi
Samples : 6
Temperature controlling mode : Automatic digital temperature
Temperature controlling range : Room temperature ~ 160 °C
Temperature controlling accuracy : ± 0.2 °C
Measuring Range : 10℃ to 35 ℃
Repeatability Error : ≤ 0.2% (Grade C)
Bomb Pressure : 20 MPa
Working Environment : Temperature Range:15 to 28 ℃ Relative Humidity: ≤ 85%
Temperature controlling range : 10 ℃ ~ 35 ℃
Temperature resolution : 0.001 ℃
Mean value of heat capacity : 15 kJ / K
Ambient temperature : 20 ℃ ± 5 ℃
Temperature measurement range : 10 ~ 35 ℃
Repeatability error : ≤ 0.2 % (Grade C)
Endured pressure in oxygen bomb : 20 MPa
Operation environment temperature : 15 ~ 28 ℃
Thermal Capacity : 8,000 to 40,000 J/K
Oxygen Bomb Capacity : 300 ml
Oxygenation Pressure : 2.0 to 3.0 MPa
Pressure Resistance : 20 MPa (Water pressure)
Heat Capacity : 10500 J/K
Working Pressure : 2.8 to 3.2 Mpa
Water Pressure Test : 20.0 Mpa
Oxygen Bomb Volume : 300ml
Porcelain crucible : 30 ml
Inner iron crucible : 75 ml
Outer iron crucible : 190 ml
Burner : Mig Burner
Coking furnace : Metal furnace
Heating mode : Electric heating
Test unit : 5 units
Temperature range : Ambient to 550°C
Bath Type : Four Holes with a Furnace
Heating Type : Electric Resistance Furnace
Temperature Controlling Range : 0 to 520℃
Temperature Controlling Accuracy : ±5℃
Measuring Range : 0.10%(m/m) to 30.0%(m/m)
Test Samples : 12
Coking Oven : Circular heating chamber, 85mm diameter by 105mm deep
Test Temperature Range : Ambient to 500°C
Sample hole : 4 pieces
Sample quantity : 4 to 12 pieces
Ambient temperature : Room temperature to 35 °C
Temperature controlling range : Room temperature to 100°C
Sample Holes : 2 holes
Temperature Control Range : RT to 99 ℃
Temperature Control Accuracy : 0.1 ℃
Mixing Motor Power : 15W
Sample hole : 4 pieces
Speed of stirring motor : 1400 rpm
Speed for sample stirring : 1000 ± 50 rpm
Ambient temperature : Room temperature to 35°C
Sample hole : 4 pieces
Ambient temperature : Room temperature to 35°C
Temperature controlling range : 0 to 100°C
Temperature controlling accuracy : ± 1°C
Measuring Range : 7ppm to 5%
Repeatability : <0.4347 (X 0.6446)
Reproducibility : <1.9182 (X 0.6446)
Detection Limit : 7 ppm
Sample quantity : 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)
Measurement time : 60, 120, 240, 300, and 600 s at random
Measurement range : 7 ppm to 5 %
Repeatability : < 0.029 (S + 0.6)
Vapor Pressure Range : 0 to 180 kPa
Accuracy : ±0.1 kPa
Measurements Positions : 3
Test Pressure Vessels : Standard stainless steel REID pressure vessel with one opening
Bath temperature : 37.8 °C
Temperature controlling accuracy : 0.1 °C
Ambient temperature : -10°C to 35°C
Relative humidity : ≤ 85 %
Operation temperature of water bath : RT to 90 °C
Temperature controlling accuracy : ± 0.1 °C
Ambient temperature : -10°C to 35 °C
Relative humidity : ≤ 85 %
Ambient Temperature : 10°C to 35°C
Measurement Range : 0 to 100 mg
Resolution : 0.1 µg
Max. Electrolysis Speed : 40 µg /s
Maximum current : 400 mA
Measurement range : 3 µg to 9999.9 µg
Resolution : 0.1 µg
Precision 1 : ± 2 µg (3µg H2O to 20µg H2O)
Measurement Range : 1 µg to 200 mg
Electrolytic Current Control : 0 to 400 mA
Sensitive Valve : 0.1 µg H2O
Accuracy : 10µg to 1000μg, ±3μg More than 1mg but not greater than 0.3%
Ambient Temperature Range : -10 to 35°C
Relative Humidity : ≤85%
Distillation Flask : 1000 ml
Receiver : 5 ml, with 0.05 ml graduation
Measuring range : 30 ppm to 100%
Resolution : 0.01 ml
Repeatability : ˂ 0.01
Moisture display resolution : 1 ppm
Measuring range : 10 ppm to 100%
Resolution : 0.001 ml
Repeatability : ≤ 0.005
Moisture display resolution : 1 ppm
Ambient Temperature Range : ≤ 35°C
Relative Humidity : ≤ 85%
Heating Mantle Cap Power : 1000 W
Sample Determination : 1 at a time
Ambient Temperature Range : ≤ 35°C
Relative Humidity : ≤ 85%
Heating Mantle Cap Power : 1000 W × 2
Sample Determination : 2 at a time
Experimental temperature range : -50 to 70°C
Test sample volume : 50 ml
Ambient temperature range : 10 to 40°C
Humidity : ≤ 85%
Vessel Volume : 4000 ml × 2
Power of Vacuum pump : 160 W
Negative power : 3.7 kPa(27.75 mmHg)
Power of shaking machine : 30 W
Capacity : 2.0 kVA
Speed of voltage increase : 2 k V/ s
Voltage inspection accuracy : 0.01
Breakdown sensitivity : Less than 0.1 kV
Measurement range : 32 ℃ to 160 ℃
Ambient temperature : 35 °C
Temperature resolution : 0.01 ℃
Beaker volume : 1000 mL
Temperature range : Room temperature to 1000 ºC
Temperature resolution : 0.1 ºC
Temperature fluctuation : ±0.1 ºC
Heating rate : 1 ~ 80 ºC / min
Temperature Range : Room temperature to 1600℃
Temperature Resolution : 0.01℃
Temperature Fluctuation : ±0.1℃
Heating Rate : 0.1 to 100℃/min
Temperature Range : RT to 1250 °C
Temperature Resolution : 0.01 ℃
Temperature Fluctuation : ± 0.1 ℃
Heating Rate : 0.1 to 100 ℃ /min
Measurement range : 0 to 600 penetration scale
Timing controller : 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec
Time accuracy : ± 0.1 seconds
Resolution : 0.01 mm
Measurement range : 0 to 600 penetration scale
Timing controller : 5 sec or 60 sec
Time accuracy : ± 0.1 seconds
Resolution : 0.01 mm
Measurement range : 0 to 600 penetration scale
Timing range : 0 sec to 60 sec
Time accuracy error : ≥ ± 0.1 seconds
Resolution : 0.1 penetration
Temperature Range : Ambient to 100°C
Temperature Precision : ± 0.1°C
Air Flow : 94 mL ± 5 mL/min, with flowmeters
Timing Unit : 0 to 99 min 59 s, resolution 1 s
Bath Temperature Control : Automatic
Bath Temperature : 24℃, 93.5℃
Temperature Accuracy : ±0.5℃
Temperature Sensor : Pt100
Potential measuring range : (0 to ±1999.5) Mv
Intrinsic error : 0.1 % ±0.5 mV
Input impedance : Ri ≥1 × 1012 Ω
Burette capacity : 10 mL
Measuring range : 0 to 700 taper degree (digital display table 0-70 mm)
Timing device : Timing error is less than ±0.1 s
Resolution : 0.01 mm
Needle insertion accuracy : ±1 cone insertion degree
Measuring range : Temperature: -5.0°C to 105.0°C pH: 0.00 to 14.00 mV: -1800 to 1800
Resolution : Temperature: 0.1°C pH: 0.01 mV: 0.1
Basic error : Temperature: ±0.3°C ± 1 word pH: ±0.01 ± 1 word mV: ±0.03% FS
Control temperature : 60°C ±1°C
Sample Types : Liquids
Determination Method : Coulometric Titration
Bias Range : 0 To 500 Mv, Optional
Salt Content : 0.2 to 10000 (NaCl) Mg/L
Test unit : 2
Sieve aperture : 75 µm
Pressure display : Precision digital pressure gauge
Cooling method : Totally enclosed compressor cooling
Dimension : 390 x 260 x 590 mm
Total power consumption : ≤ 1200 W
Power supply : AC 220 V ± 10 %, 50 Hz
Heating power of water bath : 1000 W
Power supply : AC 220 V ± 10 %, 50 Hz
Temperature controlling range in water bath : RT ~ 90 ℃ ± 5 ℃
Cooling bath temperature : (-35) ℃ ± 1 ℃
Evaporation temperature : 35 ℃ ± 1 ℃
Measurement Range : 0 to 80KV, 0 to 100KV (optional)
Measurement Accuracy : ± 3%
Number Of Experimental Cups : 1 cup
Display Mode : LCD Screen
Light source : 220 V, 100 W
Temperature of grinding milk white light bulb : 2750 ± 50 K
Light hole( Φ14) : 26 pieces
Color comparing tube : Φ32 mm
Cold Bath Volume : 6L
Cold Bath Temperature Control Range : 20℃ to -76 ℃
Cold Bath Cooling Time : RT to -78°C at ≤ 120 minutes
Hot Bath Temperature Control Range : RT to 100 ℃
Measuring Range : 1200 to 20000 mPa
Shear Rate : 10⁵ to 10⁴ s⁻¹
Temperature Range : -50℃ to 100℃
Temperature Accuracy : ±0.1℃
Booster Capacity : 1.5 kVA
Boost Speed : 0.5 kV/s to 5.0 kV/s (10 grades, increasing by 0.5)
Electrode Clearance Standard : 2.5 mm
Output Voltage : 0 to 80 kV (optional)
Maximum Pressure : 200MPa
Pressure Control Range : 0 to 2000 Bar
Fuel Injection Duration : 100 to 5000 µs
Flow Measurement Range : 0 to 4000 ml/min
Measuring Range : 0 to 50 mm
Numbers Marked : Every 10 mm
Candle Lifting Stand Stroke Range : 10 mm, with smooth and uniform movement
Wick Guide Stretches : 6 mm from the top