Calorimeter type : Isoperibol
Temperature range : 5 to 40°C
Measurement range : 5 to 40 MJ/ kg
Operation Mode : The outer barrel temperature is constant
Calorimeter type : Isoperibol
Temperature range : 5 to 40°C
Measurement range : 5 to 40 MJ/ kg
Operation Mode : A. Outer barrel temperature follows room temperature change mode Or B. Outer barrel temperature constant mode
Calorimeter type : Isoperibol
Oxygen filling : Fully automatic oxygen filling & releasing, fully automatic bomb raising & lowering
Bomb volume : 250 ml
Analysis time : < 8 min full test process: <10 min
Calorimeter type : Isoperibol
Oxygen filling : Semi-automatic
Bomb volume : 282 ml
Analysis time : 15 to 25 min
Test Liquids : Diesel, Gasoline
Measuring Range for Gasoline : Aviation gasoline: 86.0 to 105.0/MON
Automobile gasoline: 50.0 to 115.0/RON
Measuring Range for Diesel : Automobile diesel oil: 25 to 75/CN
Measuring Accuracy : Aviation gasoline: ≤ ± 1.5/MON
Automobile gasoline: ≤ ± 1.5/RON, ≤ ± 1.5/MON
Automobile diesel oil: ≤ ± 2.5/CN, ≤ ± 2.5/CI
Retest of regression samples: ≤ ± 0.5/RON, ≤ ± 0.5/MON
Test of regression sample: ≤ ± 1.5/RON, ≤ ± 1.5/MON
Calibration accuracy: ≤ ± 0.2/RON, ≤ ± 0.2/MON
Measurement item : motor gasoline and diesel
measurement unit of octane is ON : 40 to 120
Permissible error of octane : ± 0.5 max
Fluctuate range of octane : ± 0.2 max
Octane number range : 40 to 125 ON
Maximum error limit octane number : ±0.5 ON
Maximum parallel ON difference : ±0.2
Antiknock range : 0.5 to 15 %
Ambient temperature : ≤ 35 °C
Relative humidity : ≤ 85 %
Precision of titration tube : Scale division is 0.02 ml
Total power consumption : ≤ 1200 W
Measurement range : ≥0.05 mg KOH/g
Potential measurement range : 0 to 1800.0 mV
Burette volume : 10 mL
Minimum titration volume : 0.001 ml
Volumetric analysis : Titration condensation: 0.1 N;
Controlling accuracy: ≤ ± 0.02 ml
Automatic acid titration : Titration condensation: 0.1 N;
Controlling accuracy: ≤ ± 0.1 pH
Automatic potential control : Titration condensation: 0.1 N;
Controlling accuracy: ≤ 10 mV
Ambient temperature : 0 ~ 35 ℃
Graduated flask : 100 ml,50 ml
Conical flask : 100ml
Separatory funnel : 250ml
Ambient temperature : (-10 )°C to 35 °C
Measurement range : Room temperature ~ 150°C
Stirring speed : 0 ~ 1200 r / min
Heating power : 25 W
Interior Dimension : 360 × 250 × 545 mm
Temperature controlling accuracy : ≤ 0.5 ℃
Temperature controlling range : Room temperature ~ 200 ℃
Power supply for illumination : 5 V
Power of motor : 2 kW
Ambient temperature : 10 °C ~ 40 °C
Relative humidity : ≤ 80 %
Measurement Range : Ambient Temperature ~ 250 °C
Flash Point : Lower than 104 °C , error is 2 °C; Higher than 104 °C , error is 6 °C
Ambient temperature : 10 °C ~ 40 ℃
Relative humidity : ≤ 80 %
Ignition Mode : electron igniter / gas flame
Temperature range : Room Temperature ~ 300 ℃
Ambient temperature : ≤ 35 °C
Relative humidity : ≤ 85 %
Temperature range : 5 °C ~ 110 °C, Each scale division is 0.5 °C; 20 °C ~ 150 °C, Each scale division is 1.0 °C; 90 °C ~ 370 °C, Each scale division is 2 °C
Aperture of ignition device : 0.8 mm
Ambient temperature : Room temperature to 35 °C
Relative humidity : ≤ 85 %
Timing range : 1 s to 9 min 59 s
Temperature controlling range : Room temperature to 99.9 °C
Ambient temperature : Room temperature to 35 °C
Relative humidity : ≤ 85 %
Temperature controlling range : Room temperature to 99.9 °C
Temperature controlling accuracy : ± 1 °C
Cubage of bath : Ф300 × 380 mm
Temperature controlling range : 0 °C ~ 100 °C
Temperature controlling accuracy : ± 0.2 °C
Temperature sensor : Industrial platinum resistance, Pt100
Heating power : 2 kW
Cooling power : 0.5 kW
Steam temperature : 0 to 400℃
Oven temperature : 0 to 500℃
Ambient temperature : -10°C to 35°C
Relative humidity : ≤ 85 %
Thermometer : Each one for 70°C to 90°C , 100°C to120°C , and 125°C to 150°C
Scale division : 0.1 ℃
Graduated flasks : 100 ml
Distillation flask : 125 ml
Ambient temperature : ≤ 35 °C
Relative humidity : ≤ 85 %
Graduated flasks : 100 ml
Distillation flask : 125 mL
Ambient temperature : ≤ 30 °C
Relative humidity : ≤ 85 %
Graduated flasks : 100 ml
Scale division of graduated flask : 1ml
Distillation flask : 125 ml
Ambient temperature : ≤ 35 °C
Distillation flask : 125 mL
Ambient temperature : Room temperature to 35 °C
Relative humidity : ≤ 85 %
Thermometer : (-2 )°C to 300 ℃ and (-2) °C to 400 ℃
Graduated flasks : 10 ml and 100 ml
Scale division of graduated flask : 10 ml is 0.1 ml and 100 ml is 1 ml
Ambient temperature : (-10) °C ~ 35 °C
Relative humidity : ≤ 85 %
Graduated flasks : 100 ml
Scale division of graduated flask : 1 ml
Outer diameter of distillation flask : φ65
Refrigeration tube : φ14
Ambient temperature : 5 °C to 35 ℃
Relative humidity : ≤ 85 %
Cubage of buffer vessel : 1000 ml
Max. Residual pressure : ≤ 2 mm Hg
Evaporation tube specifications : 200 Φ mm
Evaporation tube heat transfer area : 0.4 m2
Built-in cooling area : 0.5 m2
Constant pressure feeding bottle : 3 L
Ambient temperature : ≤ 35 ℃
Relative humidity : ≤ 85 %
Heating power of electric furnace : 250 W × 2
Total power consumption : ≤ 700 W
Beaker quantity : 600 ml
Ambient temperature : (-10) °C ~ 40 °C
Relative humidity : ≤ 85 %
Thermometer Measurement range : (-5) °C ~ 300 °C
Graduated Flask : 200 ± 0.2 ml
Standard Water Value : 51 ± 1 s
Temperature Range : 0 ~ 100 °C
Temperature Controlling Accuracy : ± 0.2 °C
Graduated Flask : 100 ml
Standard Water Value : 51 ± 1 s
Temperature Range : 0 ~ 100 °C
Temperature Controlling Accuracy : ± 0.1 °C
Graduated Flask : 200 ± 0.2 ml (50 ± 0.2 ml for bituminous materials)
Standard Water Value : 51 ± 1 s
Temperature Range : 0 ~ 100 °C
Ambient Temperature : 10 °C ~ 40 °C
Bath type : Oil bath
Bath capacity : 5000 ml ± 50 ml
Ambient temperature : Room temperature to 35 °C
Relative humidity : ≤ 85 %
Evaporation bath type and size : Aluminum block bath, φ260 × 130 mm
Holes for testing : 3 pieces
Size of holes for testing cylinder : φ51 × 70 mm
Flow rate display : Flow meter
Evaporation bath type and size : Aluminum bath φ260 × 130 mm
Holes for testing : 5 pieces
Size of holes for testing cylinder : φ51 × 70 mm
Working temperature : 160 ℃ ~ 165℃
Ambient temperature : 15 to 35°C
Relative humidity : ≤ 85%
Capillary viscometer : 6 capillary Pinkevitch viscometer tubes
Stirring motor : 1200 rpm
Ambient temperature : (-10) °C ~ 35 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 11 pieces
Stirring motor : 6 W, 1200 rpm
Ambient temperature : (-10) °C ~ 35 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 11 pieces
Stirring motor : 6 W, 1200 rpm
Ambient temperature : (-10) °C ~ 35 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 7 pieces of Cannon-Fenske reserve-flow capillary viscometer tubes in a group
Stirring motor : 6 W, 1200 rpm
Ambient temperature : (-10) °C ~ 35 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 11 pieces
Stirring motor : 6 W, 1200 rpm
Ambient temperature : 0 ~ 40 ºC
Relative humidity : 20 ~ 90 %, RH while 40 ℃
Temperature controlling accuracy : ± 0.1 °C
Timing range : 0.0 s ~ 9999.9 s
Ambient temperature : ≤ 30 °C
Relative humidity : ≤ 85 %
Capillary viscometer : 13 pieces
Stirring motor : 6 W, 1200 rpm
Ambient temperature : ≤ 30 ℃
Refrigeration speed : > 40 °C / 10 min
Repeatability for solidifying point : ≤ 2 °C
Repeatability for pour point : ≤ 3 °C
Ambient temperature : (-10)℃ ~ 35 ℃
Relative humidity : ≤ 85 %
Sample cup Inner diameter : 31.0 ~ 32.0 mm
Sample cup Wall thickness : 1.0 ~ 1.5 mm
Freezing point range : -54°C to 2°C
Cold bath measurement temperature range : -70° to 20°C
Temperature controlling accuracy : ±0.5°C
Bath liquids stirring : Electric
Refrigeration system : New-type refrigeration compressor
Controlling temperature of cold trough : Cold trough I: 0 °C, ± 0.5 °C; Cold trough II: 0 °C, (-17) °C, ± 0.5 °C; Cold trough III: (-17) °C, (-34) °C, ± 0.5 °C; Cold trough IV: (-70) °C, ± 0.5 °C
Ambient temperature : ≤ 30 ℃
Relative humidity : ≤ 85 %
Chamber quantity : 2 chambers
Chamber 01 temperature control : Ambient to -51 ℃
Chamber 02 temperature control : Ambient to -65 ℃
Temperature precision : ±1°C
Refrigeration system : New-type refrigeration compressor
Controlling temperature of cold trough : Cold trough I: RT ~ (-51) °C, ± 1°; Cold trough II:RT ~ (-80) °C, ± 1 °C
Ambient temperature : ≤ 30 ℃
Relative humidity : ≤ 85 %
Capacity : 20 L
Temperature range : Ambient +5°C to 100°C
Precision : ± 0.1℃
Stirring range : 1200 r/min
Temperature controlling accuracy : ± 0.5 °C
Refrigeration system : New-type refrigeration compressor
Cold trough : One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough : Room temperature ~ (-70) °C
Refrigeration system : New-type refrigeration compressor
Cold trough : One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough : Room temperature ~ (-70) °C
Ambient temperature : ≤ 30 ℃
Temperature controlling accuracy : ± 0.5 ℃
Refrigeration system : New-type refrigeration compressor
Cold trough : Two holes in one trough, and same temperature
Ambient temperature : ≤ 30 ℃
Temperature controlling accuracy : ± 0.5 °C
Refrigeration system : New-type refrigeration compressor
Cold trough : One trough with two baths, temperatures in two baths are equal
Controlling temperature of cold trough : Room temperature ~ (-70) °C
Ambient Temperature : 10 ℃ ~ 40 °C
Relative Humidity : ≤ 80 %
Temperature Measurement- Full Scale : Ambient temperature to 300 °C
Temperature Measurement- Repeatability : ≤ 8 °C
Ambient Temperature : 10 ℃ ~ 40 ℃
Relative Humidity : ≤ 85 %
Temperature Measurement- Full Scale : Ambient temperature to ~ 400 ℃
Temperature Measurement- Repeatability : ≤ 4 ℃
Thermometer : 6 ℃ ~ 400 ℃
Scale Division : 2 °C
Spout Aperture : 0.6 ~ 0.8 mm
Ambient Temperature : -10 ℃ ~ 50 ℃
Thermometer : 0 ℃ ~ 360 °C
Scale Division : 1 °C
Ambient Temperature : ≤ 35 °C
Relative Humidity : ≤ 85 %
Light source : 220 V, 100 W
Temperature of grinding milk white light bulb : 2750 ± 50 K
Light hole( Φ14) : 26 pieces
Color comparing tube : Φ32 mm
Power supply : AC 220 V ± 5 % , 50Hz
Measurement range : 0 ~ 75 kV
Voltage rising rate : 3 kV ± 10 % / s
Distance between electrodes : 2.5 mm
Dimension : 390 x 260 x 590 mm
Total power consumption : ≤ 1200 W
Power supply : AC 220 V ± 10 %, 50 Hz
Heating power of water bath : 1000 W
Power supply : AC 220 V ± 10 %, 50 Hz
Temperature controlling range in water bath : RT ~ 90 ℃ ± 5 ℃
Cooling bath temperature : (-35) ℃ ± 1 ℃
Evaporation temperature : 35 ℃ ± 1 ℃
Samples : 2
Oil bath cubage : 30 L
Angle between bomb and water surface : 30 °
Speed of rotary assembly : 100 ± 5 RPM
Samples : 8
Temperature : 100 ℃
Temperature controlling accuracy : 0.1 ℃
Flow meter : 3 ± 0.3 L / H oxygen
Type : Compact; Desktop
Design : Integrated
Bath : Metal bath (without water usage)
Temperature control point of metal bath : 100℃ ± 1℃
Temperature Range : Ambient to 150℃
Temperature Precision : ± 0.1°C
Test Unit : 2 units
Heating Power : 1800 W
Samples : 6
Temperature controlling mode : Automatic digital temperature
Temperature controlling range : Room temperature ~ 160 °C
Temperature controlling accuracy : ± 0.2 °C
Heat capacity : 14000 ~ 15000 J / K
Temperature measurement range : 10 ~ 35 ℃
Repeatability error : ≤ 0.2 % (Grade C)
Endured pressure in oxygen bomb : 20 MPa
Temperature controlling range : 10 ℃ ~ 35 ℃
Temperature resolution : 0.001 ℃
Mean value of heat capacity : 15 kJ / K
Ambient temperature : 20 ℃ ± 5 ℃
Temperature measurement range : 10 ~ 35 ℃
Repeatability error : ≤ 0.2 % (Grade C)
Endured pressure in oxygen bomb : 20 MPa
Operation environment temperature : 15 ~ 28 ℃
Porcelain crucible : 30 ml
Inner iron crucible : 75 ml
Outer iron crucible : 190 ml
Burner : Mig Burner
Bath type : Four holes with a furnace
Heating type : Electric resistance furnace
Temperature controlling range : 0 ~ 520 °C
Temperature controlling accuracy : ± 5 °C
Coking furnace : Metal furnace
Heating mode : Electric heating
Test unit : 5 units
Temperature range : Ambient to 550°C
Viscosity measurement range : 10 ~ 2000000 MPa•s
Ambient temperature : 5 °C ~ 35 °C
Ambient humidity : Not more than 80 %
Spindles : Four spindles of No.1 ~ 4
Sample hole : 4 pieces
Sample quantity : 4 to 12 pieces
Ambient temperature : Room temperature to 35 °C
Temperature controlling range : Room temperature to 100°C
Sample hole : 2 pieces
Speed of stirring motor : 1400 rpm
Ambient temperature : 10 to 35°C
Temperature controlling range : Room Temperature to 100°C
Sample hole : 4 pieces
Speed of stirring motor : 1400 rpm
Speed for sample stirring : 1000 ± 50 rpm
Ambient temperature : Room temperature to 35°C
Sample hole : 4 pieces
Ambient temperature : Room temperature to 35°C
Temperature controlling range : 0 to 100°C
Temperature controlling accuracy : ± 1°C
Air flow rate : Not less than 150 L / h
Max. Preset time : 99 min 59 s (100 min)
Chamber diameter of oven : Φ22 mm
Heating power of oven : 1400 W × 2
Sample quantity : 2 to 3 ml (it is equal to sample depth of 3 mm to 4 mm)
Measurement time : 60, 120, 240, 300, and 600 s at random
Measurement range : 7 ppm to 5 %
Repeatability : < 0.029 (S + 0.6)
Test bomb : Two samples or a group of parallel samples
Bath temperature : 37.8 °C
Temperature controlling accuracy : 0.1 °C
Dimensions : 500 × 560 × 680 mm, 950 × 540 × 720 mm
Operation temperature of water bath : RT ~ 90 °C
Temperature controlling accuracy : ± 0.1 °C
Dimensions : 550 × 520 × 102 mm
Pressure meter accuracy : ± 0.4 % kPa
Ambient Temperature : 10°C to 35°C
Measurement Range : 0 to 100 mg
Resolution : 0.1 µg
Max. Electrolysis Speed : 40 µg /s
Maximum current : 400 mA
Measurement range : 3 µg to 9999.9 µg
Resolution : 0.1 µg
Precision 1 : ± 2 µg (3µg H2O to 20µg H2O)
Ambient Temperature Range : -10 to 35°C
Relative Humidity : ≤85%
Distillation Flask : 1000 ml
Receiver : 5 ml, with 0.05 ml graduation
Ambient Temperature Range : ≤ 35°C
Relative Humidity : ≤ 85%
Heating Mantle Cap Power : 1000 W
Sample Determination : 1 at a time
Ambient Temperature Range : ≤ 35°C
Relative Humidity : ≤ 85%
Heating Mantle Cap Power : 1000 W × 2
Sample Determination : 2 at a time
Experimental temperature range : -50 to 70°C
Test sample volume : 50 ml
Ambient temperature range : 10 to 40°C
Humidity : ≤ 85%
Vessel Volume : 4000 ml × 2
Power of Vacuum pump : 160 W
Negative power : 3.7 kPa(27.75 mmHg)
Power of shaking machine : 30 W
Capacity : 2.0 kVA
Speed of voltage increase : 2 k V/ s
Voltage inspection accuracy : 0.01
Breakdown sensitivity : < 0.1 kV
Measurement range : 32 ℃ to 160 ℃
Ambient temperature : 35 °C
Temperature resolution : 0.01 ℃
Beaker volume : 1000 mL
Temperature range : Room temperature to 1000 ºC
Temperature resolution : 0.1 ºC
Temperature fluctuation : ±0.1 ºC
Heating rate : 1 ~ 80 ºC / min
Measurement range : 0 to 600 penetration scale
Timing controller : 5 sec, 8 sec, 10 sec, 12 sec, 30 sec and 60 sec
Time accuracy : ± 0.1 seconds
Resolution : 0.01 mm
Measurement range : 0 to 600 penetration scale
Timing controller : 5 sec or 60 sec
Time accuracy : ± 0.1 seconds
Resolution : 0.01 mm
Measurement range : 0 to 600 penetration scale
Timing range : 0 sec to 60 sec
Time accuracy error : ≥ ± 0.1 seconds
Resolution : 0.1 penetration
Temperature Range : Ambient to 100°C
Temperature Precision : ± 0.1°C
Air Flow : 94 mL ± 5 mL/min, with flowmeters
Timing Unit : 0 to 99 min 59 s, resolution 1 s
Potential measuring range : (0 to ±1999.5) Mv
Intrinsic error : 0.1 % ±0.5 mV
Input impedance : Ri ≥1 × 1012 Ω
Burette capacity : 10 mL
Measuring range : 0 to 700 taper degree (digital display table 0-70 mm)
Timing device : Timing error is less than ±0.1 s
Resolution : 0.01 mm
Needle insertion accuracy : ±1 cone insertion degree
Measuring range : Temperature: -5.0°C to 105.0°C
pH: 0.00 to 14.00
mV: -1800 to 1800
Resolution : Temperature: 0.1°C
pH: 0.01
mV: 0.1
Basic error : Temperature: ±0.3°C ± 1 word
pH: ±0.01 ± 1 word
mV: ±0.03% FS
Control temperature : 60°C ±1°C
Test unit : 2
Sieve aperture : 75 µm
Pressure display : Precision digital pressure gauge
Cooling method : Totally enclosed compressor cooling