Labtron Plastic Testing Instruments has a microprocessor-controlled PID system that ensures precise temperature balance for consistent results. These include an inside chamber constructed from durable stainless steel, offering long-lasting reliability. Their test samples retain their physical properties even after aging, ensuring accurate assessments. They have adopted a double-pipe structure for enhanced durability and performance. Our plastic testing instruments effectively determine the anti-impact properties of materials, providing valuable data for material testing and quality control.
Dart Head Mass: 50 to 2000
Mass Increment: 5 g
Impact Height: 1500 mm
Dart Head Quality: A method: R38 ± 1 mm B method: R50 ± 1 mm
Heat Sealing Temperature: RT to 300℃
Temperature Control Accuracy: ± 1℃
Heat Sealing Time: 0.01 s to 99.99 h
Heat Sealing Pressure: 0 to 8 kg (0 to 0.8 MPa)
Heat Sealing Temperature: RT to 300℃
Temperature Control Accuracy: ± 1℃ (0.1℃ customizable)
Heat Sealing Time: 0.01 s to 99.99 h
Heat Sealing Pressure: 0 to 8 kg (0 to 0.8 MPa)
Maximum Impact Energy: 3 J
Minimum Graduation Value: 0.020 J (Option: 0.010 J)
Pendulum Lifting Angle: 90°
Pendulum Swing Radius: 265 mm
Impact Energy: Standard: 1 J, 2 J, 3 J Customizable: Up to 5 J
Resolution: 0.001 J
Punch Size: Փ 25.4 mm, Փ 12.7 mm
Sample Clamp Diameter: Փ 60 mm, Փ 89 mm
Temperature Control Range: 0℃ to 450℃
Temperature Resolution: 0.1℃
Temperature Fluctuation: ± 0.2℃
Temperature Uniformity: ± 1℃
Vacuum Degree: 0 to slightly less than -90 kPa (conventional barrel)
Vacuum Accuracy: ± 1%
Vacuum Holding Time: 99.99 h
Inlet Pressure: 0.5 to 0.65 MPa
Vacuum Degree: 0 to 95 kPa (conventional barrel)
Vacuum Accuracy: ± 1%
Vacuum Holding Time: 0.1 to 60 min
Inlet Pressure: 0.5 to 0.65 MPa
Impact Speed & Energy (charpy): 2.9 m/s for 1J, 2J, 4J, 5J & 3.8 m/s for 7.5J, 15J, 25J
Impact energy (Izod): 3.5 m/s for 1J, 2J, 4J, 5J, 7.5J, 15J, 25J
Resolution of impact energy: 0.001 J
Pendulum up angle: 160°
Temperature Range: 10 to 35°C
Maximum Falling Height: 2000 mm
Resolution Of Displacement: 1 mm
Height Error: < ± 2 mm
Maximum Sample Length: 6 inches (152.4mm)
Test Temperature: 23 ℃ ± 2 ℃
Sample Size Range: 16 mm to 152 mm
Anvil Size: 13 mm steel Plate
Seal temperature: Room temperature -250°C
Control accuracy: ± 0.2°C
Dwell time: 0.1 S to 999.9 S
Dwell pressure: 0.05 to 0.7 MPa
Standard roller: 2000 ± 50 g
Testing stations: 3
Dimension (L*W*H) tester: 320×210×550 mm (3 stations)
Weight for stations: 10 kg (3 stations)
Standard roller: 2000 ± 50 g
Testing stations: 6
Dimension (L*W*H) tester: 650×210×550 mm (6 stations)
Weight for stations: 15 kg (6 stations)
Measuring range: 0.01 to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm/ 10 min (MVR), 0.001 to 9.999 g/cm (melt density)
Measuring rate: 0.001 S
Temperature range: 50 to 400°C
Temperature precision: ± 0.5°C
Measuring range: 0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density)
Measuring rate: 0.001 S
Temperature range: 50 to 400°C
Temperature precision: ± 0.5°C
Resolution: 0.1 % O2
Measuring range: 0 to 100 % O2
Precision: ± 0.4 % O2
Response time: < 10 S
Inclined adjustable angle: 0 to 40°
Panel width: 120 mm
Test area width: 80 mm
Standard steel balls: 1/32 to 1 inch
Structure: Table Type
Maximum Deformation Measurement Range: 1mm (Vicat Test); 0.33mm (Thermal Deformation)
Display: 7-inch Touch Screen
Sample Frame: Manual
Vacuum degree: 0 to 90 KPa
Accuracy: 1 % FS
Resolution: 0.1 KPa
Vacuum chamber effective size: 270 × 210 mm
Address:Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom