info@labtron.com +44 2080 043608
Portable Spectrophotometer LSP-C11

Portable Spectrophotometer LSP-C11

Portable Spectrophotometer LSP-C11 adopts 1000 line precision blazed grating as the spectroscopic element, the silicon photocell array with large photosensitive area as the detector. The full spectrum LED with high life as the light source, and the optical resolution is less than 10 nm in the visible light range. Under the condition of d/8 geometric optical illumination recommended by CIE, spectrophotometer can accurately measure the SCI and SCE reflectance data of samples / fluorescent samples. It has stable performance, accurate color measurement and powerful function.

Request Quote
Reflect 8º(diffused illumination, 8 degree viewing angle)
Optical Geometry SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source
Standards ISO7724-1, ASTM E1164, DIN5033 Teil7
Integrating Sphere Size Φ 40 mm
Light Source Combined full spectrum LED light source, UV light source
Spectrophotometric Mode Flat Grating
Sensor Silicon photodiode array (double row 40 groups)
Wavelength Range 400 to 700 nm
Wavelength Interval 10 nm
Semi band Width 10 nm
Measured Reflectance Range 0 to 200%
Measuring Aperture MAV Φ8 mm / Φ10 mm SAV Φ4 mm / Φ5 mm
Specular Component SCI & SCE
Color Space CIE LAB, XYZ, Yxy, LCh, CIE LUV, s-RGB, βxy,DIN, Munsell (C/2)
Color Difference Formula ΔE×ab, ΔE×uv, ΔE×94, ΔE×cmc(2:1), ΔE×cmc(1:1), ΔE×00
Other Colorimetric Index WI (ASTM E313,CIE/ISO, AATCC, Hunter), YI(ASTM D1925, ASTM 313), Metamerism Index MI, Staining Fastness, Color Fastness, Color Strength, Opacity, 8° Glossiness, 555 tone classification
Illuminant D65, A , C, D50, F2(CWF), F7(DLF), F10(TPL5), F11(TL84), F12(TL83/U30)
Observer Angle 2° / 10°
Measuring Time About 1.5 s (Measure SCI & SCE about 3.2 s)
Repeatability Spectral reflectance: MAV/SCI, Standard deviation within 0.1% (400 nm to 700 nm: within 0.2%) Chromaticity value: MAV/SCI, within ΔE × ab 0.04 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration)
Inter-instrument Error MAV/SCI, Within ΔE×ab0.2 (Average for 12 BCRA Series II color tiles)
Measurement Mode Single Measurement, Average Measurement(2 to 99 times)
Locating Method Camera Locating, stabilizer cross position
Displayed Data 3.5 inch TFT color LCD, Capacitive Touch Screen
Data Port USB
Data Storage Standard 1000 Pcs, Sample 20000 Pcs
Language English
Operating temperature 0 to 40ºC
Operating humidity 0 to 85 % RH
Dimension 129 × 76 × 217 mm
Battery Li-ion battery, 6000 measurements within 8 hours
Weight Approx. 600 g
  • Designed with combined LED light source with high life and low power consumption, including UV / excluding UV
  • Dual optical path system, the optical resolution in the visible range is less than 10 nm
  • It measures the SCI and SCE spectrum of the sample at the same time
  • Accurate spectrum and lab data, used for color matching and accurate color transmission
  • USB / Bluetooth dual communication mode, wider adaptability
  • Large capacity storage space, which can store more than 30000 pieces of test data
  • Camera locating position and Stabilizer cross measurement position
  • PC software has powerful function expansion

Portable Spectrophotometer is used in plastic electronics, paint and coating, textile printing and dyeing, printing paper, automobile, medical treatment, cosmetics and food industries, as well as scientific research institutions and laboratories etc.

Accessories no.Name
1Power Adapter
2User Guide
3PC Software
4USB cable
5White and Black Calibration Cavity
6Protective Cover
7Wrist strap
8One aperture 8mm or 4mm

Compare Models

Model Reflect Optical Geometry Standards Integrating Sphere Size Light Source Spectrophotometric Mode Sensor Wavelength Range Wavelength Interval Semi band Width Measured Reflectance Range Measuring Aperture Specular Component Color Space Color Difference Formula Other Colorimetric Index Illuminant Observer Angle Measuring Time Repeatability Inter-instrument Error Measurement Mode Locating Method Displayed Data Data Port Data Storage Language Operating temperature Operating humidity Dimension Battery Weight
LSP-A30 - - - - - - High sensitivity silicon photodiode - - - - - - - - - - - - Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 - - - - - - - - - 181 × 73 × 112 mm - 800 g (without battery)
LSP-A31 - - - - - - High sensitivity silicon photodiode - - - - - - - - - - - - Light splitting reflectivity:standard deviation within 0.08% Color values: ΔE*ab<=0.03 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals) Maximum:0.05 - - - - - - - - - 181 × 73 × 112 mm - 800 g (without battery)
LSP-A10 - - - - - - Blue light enhanced sensor array - - - - - - - - - - - - Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
Maximum:0.05
- - - - - - - - - - - 550 g
LSP-A11 - - - - - - Dual light path sensor array - - - - - - - - - - - - Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),br/> Maximum:0.03
- - - - - - - - - - - 550 g
LSP-A12 - - - - - - Photoelectric diode sensor - - - - - - - - - - - - Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.03(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
Maximum:0.05
- - - - - - - - - - - 550 g
LSP-A13 - - - - - - Photoelectric diode sensor - - - - - - - - - - - - Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.02(After calibration, standard deviation of 30 measurements on test white board, 5 second intervals)
Maximum:0.04
- - - - - - - - - - - 550 g
LSP-A20 - - - - - - Dual light path sensor array - - - - - - - - - - - - Light splitting reflectivity:standard deviation within 0.08%
Color values:ΔE*ab<=0.015 (After calibration, standard deviation of 30 measurements on test white board, 5 second intervals),Maximum:0.04
- - - - - - - - - - - 550 g
LSP-A40 - D/8 (diffused illumination,8° viewing), Specular Component Included (SCI) - Φ 40 mm LED (Full band balanced LED) - 256 pixel CMOS sensor 400 to 700 nm 10 nm 10 nm 0 to 200% MAV: Φ8 mm / Φ10 mm - - - - A,B,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,U35,DLF,NBF,TL83,TL84 - 2° / 10° Chromaticity value: Max.: dE × ab< 0.1 Average: dE × ab< 0.05 Standard deviation within ΔE × ab 0.03 (when a white tile is measured 30 times at 5-seconds interval) Reflectance: Standard deviation < 0.1% - - - APP mass storage IPS Full Color Screen, 2.4 inches Without 10 years, 1 million tests - - Android, IOS, Windows 77.8 × 53.2 × 185.7 mm Rechargeable, 8000 times continuous tests, 3.7V/3000 mAh
LSP-A41 - D/8 (diffused illumination,8° viewing), SCI (Specular Component Included), SCE (Specular Component Excluded) - Φ 40 mm LED (Full band balanced LED) - 256 pixel CMOS sensor 400 to 700 nm 10 nm 10 nm 0 to 200% MAV: Φ8 mm / Φ11 mm MAV: Φ4 mm / Φ6 mm MINI: 1×3 mm - - - - A,B,C,D50,D55,D65,D75,F1,F2,F3,F4,F5,F6,F7,F8,F9,F10,F11,F12,CWF,U30,U35,DLF,NBF,TL83,TL84 - 2° / 10° Chromaticity value: Max.: dE × ab< 0.04 Average: dE × ab< 0.03 Standard deviation within ΔE × ab 0.02 (when a white tile is measured 30 times at 5-seconds interval) Reflectance: Standard deviation < 0.1% - - - APP mass storage IPS Full Color Screen, 2.4 inches With 10 years, 1 million tests - - Android, IOS, Windows 77.8 × 53.2 × 185.7 mm Rechargeable, 8000 times continuous tests, 3.7V/3000 mAh
LSP-C10 8º(diffused illumination, 8 degree viewing angle) SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source ISO7724-1, ASTM E1164, DIN5033 Teil7 Φ 40 mm Combined full spectrum LED light source, UV light source Flat Grating Silicon photodiode array (double row 40 groups) 400 to 700 nm 10 nm 10 nm 0 to 200% MAV Φ8 mm / Φ10 mm SAV Φ4 mm / Φ5 mm SCI & SCE CIE LAB, XYZ, Yxy, LCh, CIE LUV, s-RGB, HunterLab, βxy,DIN Lab99 Munsell (C/2) ΔE×ab, ΔE×uv, ΔE×94, ΔE×cmc(2:1), ΔE×cmc(1:1), ΔE×00, DINΔE99, ΔE (Hunter) WI (ASTM E313,CIE/ISO, AATCC, Hunter), YI(ASTM D1925, ASTM 313), Metamerism Index MI, Staining Fastness, Color Fastness, Color Strength, Opacity, 8° Glossiness, 555 tone classification D65, A , C, D50, D55, D75, F1, F2(CWF), F3, F4, F5, F6, F7(DLF), F8, F9, F10(TPL5), F11(TL84), F12(TL83/U30) 2° / 10° About 1.5 s (Measure SCI & SCE about 3.2 s) Spectral reflectance: MAV/SCI, Standard deviation within 0.08% (400 nm to 700 nm: within 0.18%) Chromaticity value: MAV/SCI, within ΔE × ab 0.02 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) MAV/SCI, Within ΔE×ab0.15 (Average for 12 BCRA Series II color tiles) Single Measurement, Average Measurement(2 to 99 times) Camera Locating, stabilizer cross position 3.5 inch TFT color LCD, Capacitive Touch Screen USB, Bluetooth 4.2 Standard 1000 Pcs, Sample 30000 Pcs English 0 to 40ºC 0 to 85 %RH 129 × 76 × 217 mm Li-ion battery, 6000 measurements within 8 hours Approx. 600 g
LSP-C11 8º(diffused illumination, 8 degree viewing angle) SCI (specular component included)/SCE (specular component excluded) Include UV / excluded UV light source ISO7724-1, ASTM E1164, DIN5033 Teil7 Φ 40 mm Combined full spectrum LED light source, UV light source Flat Grating Silicon photodiode array (double row 40 groups) 400 to 700 nm 10 nm 10 nm 0 to 200% MAV Φ8 mm / Φ10 mm SAV Φ4 mm / Φ5 mm SCI & SCE CIE LAB, XYZ, Yxy, LCh, CIE LUV, s-RGB, βxy,DIN, Munsell (C/2) ΔE×ab, ΔE×uv, ΔE×94, ΔE×cmc(2:1), ΔE×cmc(1:1), ΔE×00 WI (ASTM E313,CIE/ISO, AATCC, Hunter), YI(ASTM D1925, ASTM 313), Metamerism Index MI, Staining Fastness, Color Fastness, Color Strength, Opacity, 8° Glossiness, 555 tone classification D65, A , C, D50, F2(CWF), F7(DLF), F10(TPL5), F11(TL84), F12(TL83/U30) 2° / 10° About 1.5 s (Measure SCI & SCE about 3.2 s) Spectral reflectance: MAV/SCI, Standard deviation within 0.1% (400 nm to 700 nm: within 0.2%) Chromaticity value: MAV/SCI, within ΔE × ab 0.04 ( When a white calibration plate is measured 30 times at 5 second intervals after white calibration) MAV/SCI, Within ΔE×ab0.2 (Average for 12 BCRA Series II color tiles) Single Measurement, Average Measurement(2 to 99 times) Camera Locating, stabilizer cross position 3.5 inch TFT color LCD, Capacitive Touch Screen USB Standard 1000 Pcs, Sample 20000 Pcs English 0 to 40ºC 0 to 85 % RH 129 × 76 × 217 mm Li-ion battery, 6000 measurements within 8 hours Approx. 600 g
LSP-C12 - - CIE No.15, GB/T 3978, GB 2893, GB/T 18833, ISO7724-1, ASTM E1164, DIN5033 Teil7 - - - Dual column high precision CMOS array sensor - - - - - - - - - - - - ≤0.02 - - - - - - - - - - - 750g

Most Viewed

Customer Enquiry Form

Ask Expert

Address: Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608

Copyright © 2024 Labtron Equipment Ltd. All rights reserved.