info@labtron.com +44 2080 043608
Single Beam UV-Vis Spectrophotometer LUS-C10

Single Beam UV-Vis Spectrophotometer LUS-C10

Single Beam UV-Vis Spectrophotometer LUS-C10 is a compact, table top unit, comprising Silicon photodiode detector, Tungsten and Deuterium lamp as light source. Features 200 nm to 1000 nm wavelength range, 4.0 nm bandwidth with automatic setting of wavelength, direct input by K, B factor for quantitative measurement of standard curve. Designed with single chip microcomputer control, LCD screen to display multiple sets of data, large memory storage, it provides rich measurement methods with high performance and reliability.

Request Quote
Wavelength Range 200 to 1000 nm
Spectral Bandwidth 4.0 nm
Optical System Single beam
Wavelength Accuracy ±0.2 nm
Wavelength Repeatability 0.2 nm
Wavelength Resolution 0.1 nm
Photometric Display Range -4 to 4 A
Photometric Mode T, A, C, E
Photometric Accuracy ±0.2% τ
Photometric Repeatability 0.2% τ
Light Source Tungsten lamp, Deuterium lamp
Stray Light ≤0.05% τ (220 nm NaI, 340 nm NaNO2)
Stability 0.001 A/h @500 nm
Noise ± 0.002 A @500 nm
Display LCD display (128*64 dots)
Baseline Flatness ± 0.001 A
Detector Silicon photodiode
Power Supply AC 220/110 V, 50/60 Hz
Dimensions (L×W×H) 460×330×210 mm
Net Weight 11 kg
  • Compact, table top, single beam designed UV-Vis spectrophotometer
  • Designed with silicon photodiode detector, tungsten and deuterium lamp as light source
  • Wide wavelength range of 200 nm to 1000 nm with automatic setting
  • LCD screen displays multiple sets of data
  • Maximum 10 point standard curve measurement function
  • Direct input by K, B factor for quantitative measurement of standard curve
  • Large memory space to store multiple sets of data and curve
  • Produce High performance and reliable results with user-friendly interface

Single Beam UV-Visible Spectrophotometer are used for analysis of band gap, optical coatings and thin films, quantitative analyses, kinetics, wavelength scanning, and DNA and Protein analysis across biological research, bio-industry, pharmaceutical analysis, pharmaceutical, teaching and research, environmental protection, food hygiene, clinical examination, health and epidemic prevention and other fields.

1 cm quartz cuvette- 2 pcs
1 cm glass cuvette- 4 pcs
Dust cover- 1 pc
Power line- 1 pc
Instructional Manual- 1 pc

Compare Models

Model Wavelength Range Spectral Bandwidth Optical System Wavelength Accuracy Wavelength Repeatability Wavelength Resolution Photometric Display Range Photometric Mode Photometric Accuracy Photometric Repeatability Light Source Stray Light Stability Noise Display Baseline Flatness Detector Power Supply Dimensions (L×W×H) Net Weight
LUS-A50 - - - ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all ≤ 0.1 nm - - - 0.2%T (0 to 100 %T), ±0.002A(0 to 0.5 A), ±0.004A (0.5 to 1 A) ≤0.15 % T (0 to 100 %T), 0.001A (0 to 0.5A), 0.002A (0.5 to 1A) - - ± 0.0005 A/h @ 500 nm 0.0005 A @ 500 nm 10.1 inches TFT colored capacitive touch screen - Imported silicon photodiode - - -
LUS-A51 - - - ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all ≤ 0.1 nm - - - 0.2%T (0 to 100 %T), ±0.002A(0 to 0.5 A), ±0.004A (0.5 to 1 A) ≤0.15 % T (0 to 100 %T), 0.001A (0 to 0.5A), 0.002A (0.5 to 1A) - - ± 0.0005 A/h @ 500 nm 0.0005 A @ 500 nm 10.1 inches TFT colored capacitive touch screen - Imported silicon photodiode - - -
LUS-A52 - - - ± 0.1nm @ 656.1 nm, ± 0.3 nm @ all ≤ 0.1 nm - - - 0.2%T (0 to 100 %T), ±0.002A(0 to 0.5 A), ±0.004A (0.5 to 1 A) ≤0.15 % T (0 to 100 %T), 0.001A (0 to 0.5A), 0.002A (0.5 to 1A) - - ± 0.0005 A/h @ 500 nm 0.0005 A @ 500 nm 10.1 inches TFT colored capacitive touch screen - Imported silicon photodiode - - -
LUS-A10 190 ~ 1100 nm 1 nm - ± 0.3 nm 0.2 nm - - - ± 0.3 % T 0.2 % T Deuterium & Tungsten Halogen Lamp ≤ 0.05 % T at 220 nm, 360 nm 0.002 A / h at 500 nm ± 0.001 A - ± 0.001 A Silicon Photodiode - - -
LUS-A11 190 ~ 1100 nm 1.8 nm - ± 0.3 nm 0.2 nm - - - ± 0.3 % T 0.2 % T Deuterium & Tungsten Halogen Lamp ≤ 0.05 % T at 220 nm, 360 nm 0.002 A / h at 500 nm ± 0.001 A - ± 0.001 A Silicon Photodiode - - -
LUS-A20 190 ~ 1100 nm 2 nm - ± 0.5 nm ≤ 0.2 nm - - T,A,C,E ± 0.3 % T 0.15 % τ Import Deuterium Lamp & Tungsten Halogen Lamp ≤ 0.05 % T at 220 nm, 360 nm 0.001 A / h at 500 nm - - - Import Silicon Photodiode - - -
LUS-A21 190 ~ 1100 nm 1.8 nm - ± 0.3 nm ≤ 0.1 nm - - T,A,C,E ± 0.3 % τ(0 - 100 % τ) ; ± 0.002A(0 ~ 0.5 A) ; ± 0.003 A (0.5 A ~ 1 A) 0.15% τ(0-100%τ); ± 0.001 A(0 ~ 0.5 A) ; ± 0.0015 A(0.5 A ~ 1 A) Import Deuterium Lamp & Tungsten Halogen Lamp ≤ 0.05 % T at 220 nm, 360 nm 0.0005 A / h at 500 nm ± 0.0002 A at 500 nm - ± 0.001 A Import Silicon Photodiode - - -
LUS-A30 190 ~ 1100 nm 4 nm - ± 0.5 nm ≤ 0.2 nm - - T,A,C,E ± 0.3 % T 0.15 % τ Import Deuterium Lamp & Tungsten Halogen Lamp ≤ 0.05 % T at 220 nm, 360 nm 0.001 A / h at 500 nm - - - Import Silicon Photodiode - - -
LUS-A40 190 ~ 1100 nm 0.5 / 1.0 / 2.0 / 4.0 / 5.0 nm - ± 0.3 nm 0.2 nm - - - ± 0.3 % T 0.2 % T Deuterium & Tungsten Halogen Lamp ≤ 0.05 % T at 220 nm, 360 nm 0.002 A / h at 500 nm ± 0.001 A - ± 0.001 A Silicon Photodiode - - -
LUS-A22 190 ~ 1100 nm 0.5 nm, 1 nm, 2 nm, 4 nm adjustable - ± 0.3 nm ≤ 0.1 nm - - T,A,C,E ± 0.3 % τ(0 - 100 % τ) ± 0.002 A (0 to 0.5 A) ± 0.003 A(0.5 A to 1 A) 0.15 % τ(0 - 100 % τ); ± 0.001 A(0 to 0.5 A); ± 0.0015 A(0.5 A to 1 A) Imported Deuterium Lamp & Tungsten Halogen Lamp ≤ 0.05 % T at 220 nm, 360 nm 0.0005 A / h at 500 nm ± 0.0002 A at 500 nm - ± 0.001 A Imported Silicon Photodiode - - -
LUS-C10 200 to 1000 nm 4.0 nm Single beam ±0.2 nm 0.2 nm 0.1 nm -4 to 4 A T, A, C, E ±0.2% τ 0.2% τ Tungsten lamp, Deuterium lamp ≤0.05% τ (220 nm NaI, 340 nm NaNO2) 0.001 A/h @500 nm ± 0.002 A @500 nm LCD display (128*64 dots) ± 0.001 A Silicon photodiode AC 220/110 V, 50/60 Hz 460×330×210 mm 11 kg