Labtron Spectrometer presents a wide range of models such as FTIR, Atomic Fluorescence, ICP, Xray Fluorescence (XRF), Angular, Optical Emission, and Gamma Spectrometer. These utilize advanced technologies like gold-coated reflecting mirrors and high-intensity light sources. Full-digital spark optical systems ensure high sensitivity and accuracy of the spectrometer. Their user-friendly software enables seamless data manipulation and non-destructive analysis. They facilitate real-time inspections and reliable results for a wide range of elements. Our Spectrometer’s robust construction and safety features guarantee durability and secure operation.
Wavelength Range : 7800 cm⁻¹ to 350 cm⁻¹
Wavelength Accuracy : ±0.01 cm⁻¹
Resolution : 0.85 cm⁻¹
Temperature : 10°C 30°C
Beam Configuration : Dual Channel
Precision ( RSD ) : < 1.0
Linear range : More than 3 orders of magnitude
Lamp : Hollow cathode lamp
Wavelength range ( 3600 lines / mm ) : 180 to 500 nm
Wavelength range ( 2400 lines / mm ) : 180 to 800 nm
Temperature : 20 ~ 28 °C
Elements per minute : 26 elements
Wavelength range : 180 to 900 nm
Elements per minute : 15 elements
Temperature : 29 °C
Incident slit : 25 µm
Wavelength range : 195 to 800 mm
Elements per minute : 10 elements
Temperature range : 32 °C
Incident slit : 20 µm
Analytical Method : Energy dispersive X-ray fluorescence analytical Method
Elements Measuring : Atomic number from 12 to 92 [elements from magnesium (Mg) to uranium (U)] can be measured
Range : Simultaneous detector
Content measurement range : ppm to 100%
Analytical Method : Energy-Dispersive X-Ray Fluorescence
Elements Measuring Range : Atomic Number From 12 To 92 [Magnesium (Mg) To Uranium (U)]
Elements Analysis Limit : 40 Elements (Simultaneous)
Measurement Range : ppm to 99.99%
Analytical Method : Energy Dispersive X-ray Fluorescence
Elements Measuring Range : Atomic Number From 12 To 92 [Magnesium (Mg) To Uranium (U)]
Elements Analysis Limit : 40 Elements (Simultaneous)
Measurement Range : ppm to 99.99%
Measureable elements : S to U
Detection limit : 1 ppm
Temperature : 15 ~ 30 °C
Elemental content : 1 ppm to 99 %
Analyzable elements : Sulfur (S) to Uranium (U)
Detection limit of the analysis : 1 ppm
Analyzable content : 1 ppm to 99.99%
Detector : SDD Detector
Measurable Elements : Sodium (Na) to Uranium (U )
Precision : 0.0005
Analytical Range : ppm to 99.99 %
Analysis Time : 60 sec to 200 sec
Angle Measurement Accuracy : 1inch
Dimensions (W×D×H) : 251×518×250 mm
Net Weight : 11.8 kg
Optical System Focal Length : 400nm
Wavelength Range : 165nm to 589nm
Detector : High-resolution CCD Multi detectors
Degree Of Vacuum : Auto control within 6-20 pa
Detector : 1.5-inch LaBr₃ Detector, GM tube, Neutron detector
Dose Rate Range : 100nSv/h to 30mSv/h
Dose Range : 100nSv to 10Sv
Detection Time : Nuclides Within 5 Seconds Mixed Nuclides Within 30 Seconds
Wavelength Range : 0.00916nm to 0.103nm
Mass Range : 2 to 255 amu
Test Range : ˃ 10⁸
Linear Range : ≥ 10⁸
Spectral Range : 201nm to 810nm
Sample type : Lubricating oil, hydraulic oil, fuel oil, grease, antifreeze, cooling water, electrolyte, etc
Elements : Al, Ba, B, Ca, Cr, Cu, Fe, Pb, Mg, Mn, Mo, Ni, K, Na, Si, Ag, Sn, Ti, V, Zn
Injection Volume : ≤2ml