Request A Quote
Tabletop Autoclave LTTA-F10

Tabletop Autoclave LTTA-F10

Tabletop Autoclave LTTA-F10 features a 35-liter chamber and supports sterilizing temperatures from 55℃ to 134℃, ideal for a wide range of applications. It uses multiple pulse-vacuum cycles for effective sterilization of wrapped, unwrapped, and hollow items. A self-diagnosis function helps detect malfunctions, making maintenance simple. Our tabletop autoclave is made of durable SUS316 stainless steel, ensuring long-lasting performance and corrosion resistance.

Tabletop Autoclave LTTA-F10(1)
Tabletop Autoclave LTTA-F10(2)
Request Quote
Chamber Volume 35 L
Sterilizing Temperature Range 55℃ to 134℃
Maximum Working Temperature 134℃ ± 1℃
Maximum Working Pressure 0.22 MPa
Timer Range 1 to 99 minutes
Drying Time Range 1 to 99 minutes
Vacuum Limit -0.08 MPa
Heat Distribution (Hot Average) ≤ 2℃
Power Supply AC 220V / 50Hz
Dimension 730 × 550 × 510 mm
Packaging Dimension 810 × 680 × 650 mm
Net Weight 73 Kg
Gross Weight 90 Kg

Drying function

Built-in printer

Safety Door Lock

Overpressure Protection

Low Water Protection

Overcurrent Protection

Tabletop Autoclave LTTA-F10 kills harmful microorganisms to ensure safety and sterility in labs, clinics, studios, and industries.

Models of Table Top Autoclave

Labtron Table Top Autoclave offer compact sterilizer of 18 L to 50 L that fits easily on workstation. Their effective sterilization is achieved through steam under pressure of 0.22 Mpa. They feature over-temperature monitoring and multiple evaporator controls for enhanced safety. Their quick cycle times significantly enhance workflow efficiency, reducing downtime between procedures. Our Table Top Autoclave is ideal for modest scale sterilization in medical, dental and research labs.

Tabletop Autoclave LTTA-G10

Tabletop Autoclave LTTA-G10

  • Capacity : 18L
  • Chamber Volume : Ø250×370
  • Temperature Range : 121°C and 134°C
  • Sterilization Temperature : 134℃
Table Top Autoclave LTTA-I11

Table Top Autoclave LTTA-I11

  • Volume : 60L
  • Working Temperature : 105 to 138°C
  • Working Pressure : 0 to 0.25 Mpa
  • Design Pressure : -0.1 / 0.3 Mpa
Tabletop Autoclave LTTA-H14

Tabletop Autoclave LTTA-H14

  • Capacity : 8 L
  • Chamber Volume : Ø170 × 320 mm
  • Working Sterilization Temperature : 134℃
  • Working Sterilization Pressure : 0.22 Mpa
Tabletop Autoclave LTTA-D10
Tabletop Autoclave LTTA-D10
  • Capacity : 20 L
  • Working Pressure : 0.22 MPa
  • Working Temperature : 134°C
  • Temperature Range : 105 to 134°C
Tabletop Autoclave LTTA-A20
Tabletop Autoclave LTTA-A20
  • Capacity : 24 L
  • Sterilization Temperature : 134 °C
  • Temperature Range : 105 to 134 °C
  • Pressure : 0.22 Mpa
Tabletop Autoclave LTTA-H16

Tabletop Autoclave LTTA-H16

  • Capacity : 18 L
  • Chamber Volume : Ø250 × 370 mm
  • Working Sterilization Temperature : 134℃
  • Working Sterilization Pressure : 0.22 Mpa
Tabletop Autoclave LTTA-F20

Tabletop Autoclave LTTA-F20

  • Capacity : 18L
  • Chamber Size : Ø250 × 370 mm
  • Rated Working Temperature : 134℃
  • Temp. Accuracy : ±1℃
Tabletop Autoclave LTTA-A11

Tabletop Autoclave LTTA-A11

  • Capacity : 24 L
  • Sterilization Temperature : 134 °C
  • Temperature Range : 105 to 134 °C
  • Pressure : 0.22 Mpa

Tabletop Autoclave LTTA-F10 FAQ's
  • A Labtron Tabletop Autoclave is a compact sterilization unit designed to eliminate harmful microorganisms from medical instruments, laboratory tools, and other equipment. It uses high-pressure steam and precise temperature control to kill bacteria, viruses, fungi, and spores. The autoclave operates using multiple pulse-vacuum cycles, which enhance the penetration of steam into complex items like hollow instruments or wrapped tools. These cycles remove air pockets, allowing thorough sterilization. Labtron designs its tabletop autoclaves with advanced features such as accurate temperature settings, drying functions, and automated safety controls to make the sterilization process both effective and user-friendly.

  • Labtron Tabletop Autoclaves are equipped with multiple safety mechanisms to ensure secure operation. Some of the key safety features include an automatic safety door lock that prevents the chamber from opening under pressure, overpressure protection to release excess steam safely, and low water protection to alert users if the water level drops too low. Additionally, overcurrent protection guards against electrical faults. These built-in systems help prevent accidents, extend the life of the autoclave, and reduce the need for frequent maintenance. Labtron prioritizes user safety and reliable operation in every autoclave it manufactures.

  • Labtron Tabletop Autoclaves are highly versatile and can sterilize a wide range of items commonly used in laboratories, clinics, beauty studios, and small industrial settings. These include metal instruments, glassware, surgical tools, dental equipment, wrapped or unwrapped items, and even hollow objects like pipette tips or tubing. The combination of high temperature (up to 134°C) and adjustable vacuum settings allows efficient sterilization of both simple and complex instruments. Labtron’s autoclaves are especially valuable in environments where maintaining sterility is critical to safety and compliance standards.

  • The drying function in Labtron Tabletop Autoclaves plays a crucial role in ensuring complete sterilization and maintaining item integrity. After the steam sterilization cycle is complete, the autoclave uses vacuum drying to remove residual moisture from the sterilized instruments. Moisture left behind can lead to microbial growth or rusting of metal tools. The drying cycle helps ensure that all instruments are not only sterile but also ready for immediate use or storage. This feature is particularly beneficial in laboratories and medical practices where instruments need to remain contamination-free for extended periods.

  • Labtron uses SUS316 stainless steel to manufacture the inner chambers of its tabletop autoclaves due to its exceptional durability and corrosion resistance. SUS316 is a high-grade alloy known for withstanding repeated exposure to high temperatures, pressure, and moisture—conditions typical of sterilization cycles. It also resists damage from harsh chemicals, which might be present in cleaning solutions or contaminated tools. By using this high-quality material, Labtron ensures its autoclaves provide long-term, reliable performance and require minimal maintenance, even under heavy daily use.

Post your question?

Our experts are here to help!

Table Top Autoclave:
Tabletop Autoclave LTTA-G10, Table Top Autoclave LTTA-I11, Tabletop Autoclave LTTA-H14, Tabletop Autoclave LTTA-D10, Tabletop Autoclave LTTA-A20, Tabletop Autoclave LTTA-H16, Tabletop Autoclave LTTA-F20, Tabletop Autoclave LTTA-A11, and more.

Catalogs : Laboratory Equipment Catalog, Analytical Equipment Catalog, Medical Equipment Catalog, Test Equipment Catalog, Petroleum Testing Catalog, Pharmaceutical Machinery Catalog, Security Systems Catalog, Lab Products Catalog.

Need a Product

send details for best price quotation

Click
For

Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com

WhatsApp: +44 20 8004 3587

Phone: +44 2080 043608

Newsletter

Subscribe now to receive monthly news & personalised offer!

Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608

Copyright © 2025 Labtron Equipment Ltd. All rights reserved.