| Capacity | 35 L |
| Sterilizing Temperature Range | 55℃ to 134℃ |
| Maximum Working Temperature | 134℃ ± 1℃ |
| Maximum Working Pressure | 0.22 MPa |
| Timer Range | 1 to 99 minutes |
| Drying Time Range | 1 to 99 minutes |
| Vacuum Limit | -0.08 MPa |
| Heat Distribution (Hot Average) | ≤ 2℃ |
| Power Supply | AC 220V / 50Hz |
| Chamber Size | 300 × 500 mm |
| Dimension | 730 × 550 × 510 mm |
| Packaging Dimension | 810 × 680 × 650 mm |
| Net Weight | 73 Kg |
| Gross Weight | 90 Kg |
Drying function
Built-in printer
Safety Door Lock
Overpressure Protection
Low Water Protection
Overcurrent Protection
Tabletop Autoclave LTTA-F10 kills harmful microorganisms to ensure safety and sterility in labs, clinics, studios, and industries.
Download catalog for
Tabletop Autoclave LTTA-F10 Catalog
Available Range :
Tabletop Autoclave LTTA-H15 : 12 L Tabletop Autoclave LTTA-H12 : 18 L Table Top Autoclave LTTA-J10 : 18L Tabletop Autoclave LTTA-A10 : 20 L Tabletop Autoclave LTTA-H13 : 23 L Tabletop Autoclave LTTA-A11 : 24 L Tabletop Autoclave LTTA-J11 : 24L Tabletop Autoclave LTTA-A12 : 35 L Tabletop Autoclave LTTA-K10 : 35L Tabletop Autoclave LTTA-I10 : 45L Tabletop Autoclave LTTA-A13 : 50 L Tabletop Autoclave LTTA-K11 : 50L Tabletop Autoclave LTTA-I11 : 60L Tabletop Autoclave LTTA-H10 : 8 L Tabletop Autoclave LTTA-A14 : 80 L
Labtron Table Top Autoclave offer compact sterilizer of 18 L to 50 L that fits easily on workstation. Their effective sterilization is achieved through steam under pressure of 0.22 Mpa. They feature over-temperature monitoring and multiple evaporator controls for enhanced safety. Their quick cycle times significantly enhance workflow efficiency, reducing downtime between procedures. Our Table Top Autoclave is ideal for modest scale sterilization in medical, dental and research labs.








A Labtron Tabletop Autoclave is a compact sterilization unit designed to eliminate harmful microorganisms from medical instruments, laboratory tools, and other equipment. It uses high-pressure steam and precise temperature control to kill bacteria, viruses, fungi, and spores. The autoclave operates using multiple pulse-vacuum cycles, which enhance the penetration of steam into complex items like hollow instruments or wrapped tools. These cycles remove air pockets, allowing thorough sterilization. Labtron designs its tabletop autoclaves with advanced features such as accurate temperature settings, drying functions, and automated safety controls to make the sterilization process both effective and user-friendly.
Labtron Tabletop Autoclaves are equipped with multiple safety mechanisms to ensure secure operation. Some of the key safety features include an automatic safety door lock that prevents the chamber from opening under pressure, overpressure protection to release excess steam safely, and low water protection to alert users if the water level drops too low. Additionally, overcurrent protection guards against electrical faults. These built-in systems help prevent accidents, extend the life of the autoclave, and reduce the need for frequent maintenance. Labtron prioritizes user safety and reliable operation in every autoclave it manufactures.
Labtron Tabletop Autoclaves are highly versatile and can sterilize a wide range of items commonly used in laboratories, clinics, beauty studios, and small industrial settings. These include metal instruments, glassware, surgical tools, dental equipment, wrapped or unwrapped items, and even hollow objects like pipette tips or tubing. The combination of high temperature (up to 134°C) and adjustable vacuum settings allows efficient sterilization of both simple and complex instruments. Labtron’s autoclaves are especially valuable in environments where maintaining sterility is critical to safety and compliance standards.
The drying function in Labtron Tabletop Autoclaves plays a crucial role in ensuring complete sterilization and maintaining item integrity. After the steam sterilization cycle is complete, the autoclave uses vacuum drying to remove residual moisture from the sterilized instruments. Moisture left behind can lead to microbial growth or rusting of metal tools. The drying cycle helps ensure that all instruments are not only sterile but also ready for immediate use or storage. This feature is particularly beneficial in laboratories and medical practices where instruments need to remain contamination-free for extended periods.
Labtron uses SUS316 stainless steel to manufacture the inner chambers of its tabletop autoclaves due to its exceptional durability and corrosion resistance. SUS316 is a high-grade alloy known for withstanding repeated exposure to high temperatures, pressure, and moisture—conditions typical of sterilization cycles. It also resists damage from harsh chemicals, which might be present in cleaning solutions or contaminated tools. By using this high-quality material, Labtron ensures its autoclaves provide long-term, reliable performance and require minimal maintenance, even under heavy daily use.