Sample (size) length : 90 to 200 mm
Sample width : 15 mm, 25 mm, 50mm
Measuring range : 0 to 30, 0 to 100 N,0 to 300 N
Accuracy : ± 1 %
Sample (size) length : 180 mm (180, 150, 100, 90, 50 mm adjustable)
Sample width : 15 mm
Measuring range : 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Accuracy : ± 1 %
Measuring scope : ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s)
Accuracy : ±0.1 s within 300 s
Vacuum system volume (ml) : Bigger volume: 380 ± 1 Smaller volume: 38 ± 1
Contact pressure : 100 ± 2 kPa
Measuring range : 0.1 to 10 kN
Indication error : < ± 1%
Platen Size : 500×500 mm (customized)
Operating stroke : 500 mm (customized)
Measuring range : 1 to 50 kN
Indication error : < ± 1%
Platen Size : 800×800 mm/ 1000×1000 mm/ 1200×1200 mm/ 1500×1500 mm (customized)
Operating stroke : 800 mm/ 1000 mm/ 1200 mm/ 1500 mm (customized)
Sample diameter : 125 mm
Sample error : ± 0.2 mm
Sample Thickness : 0.1 to 1.0 mm
Dimension : 240×288×435 mm
Measurement range : 0.01 to 10 N
Slider weight : 200 g
Slider size : 63×63 mm
Testing accuracy : ± 2 %
Measurement range : 5 to 500 N, 50 to 3000 N
Resolution : 1 N
Accuracy : ± 1 %
Variability : ≤ 1 %
Measuring range : 0 to 5 mm
Division value : 0.001 mm
Measuring parallelism : ≤ 0.002 mm
Indication error : ± 0.0025 mm or ± 0.5 %
Testing speed : 200° ± 20° / min
Test range : 1 to 10000 mN
Indicating Error : ± 1 %
Testing length : 5, 10, 15, 20, 25, 50 mm
Capacity : 10 -16000 mN
Resolution : 0.1 mN
Tearing arm : 104 ± 1 mm
Tearing angle : 27.5° ± 5°
Measuring scope : 0 to 99999 s
Folding angle : 135° ± 2°
Tensile scope : 4.9 to 14.7 N
Folding head suture size : 0.25 mm, 0.50 mm, 0.75 mm, 1.00 mm
Sample size (L*B) : 230×50 mm (can join short samples together)
Rub pressure : 20 ± 0.2 N
Friction speed : 43 times / min
Friction area (L*B) : 155×50 mm
Measuring Range : A file: 20 to 500 J/m² B file: 500 to 1000 J/m²
Specimen Size : 25.4mm × 25.4mm
Sample Clamping Force : 0 to 400N (adjustable)
Impact Angle : 90°
Measurement range : 0 to 5600 kPa
Accuracy : ± 0.5 % F.S.
Compression speed : 170 ± 15 ml/min
Clamp pressure : ≥ 690 kPa
Measurement range : 50 to 1600 kPa-paper and 50 to 5600 kPa-paper
Resolution : 0.01 kPa
Accuracy : ≤± 0.5 %
Compression speed : 95 ± 5 ml/min
Measuring range : 0 to 1000 ml/min
Test area : 10 ± 0.02 cm2
Area differential pressure : 1 ± 0.01 kPa
Inner diameter of grip ring : 35.68 ± 0.05 mm
Measuring range : 0 to 4 mm
Accuracy : 0.01 or 0.001 mm
Gauge : Analogue gauge display
Contact pressure (to create false weight) : 100 ± 10 kPa
Measuring range : 0 to 20 mm
Accuracy : 0.01 mm
Gauge : Analogue gauge display
Contact pressure (to create false weight) : 20 ± 0.5 kPa
Measuring range : 0 to 1000 mN
Resolution : 0.1 mN
Indication error : ± 1 %
Tearing arm : 104 ± 1 mm
Measurement range : 0 to 100° SR
Sealed testing speed : 100 ± 10 mm/s
Volume of distilled water : 1000 ± 5 ml
Draining time : 149 ± 1 s
Measuring range : A (1 to 6) J indicating error ± 0.05 J B (1 to 12) J indicating error ± 0.05 J C (1 to 24) J indicating error ± 0.05 J D (1 to 48) J indicating error ± 0.05 J The indicating errors w.r.t measurement range of 20 to 80 %
Frictional resistance :
Pyramid dimension : Three sides: 60×60×60 mm, height 25 ± 0.7 mm, Arris edge fillet radius 1.5 ± 0.1 mm
Dimension : 800×470×840 mm
Measuring range : 10 to 1000 mN
Division value : 1 mN
Accuracy : ± 1%
Indicating Error : ≤ 0.5
Sample width : 15 mm
Sample maximum length : 300 mm
Parallelism : ≤ 0.1 mm
Dimension : 240×520×70 mm
Sample (size) length : 38×70 mm
Measuring range : (1-500) mN.m (divided into 7 small ranges)
Indication error : 0.02
Test speed : (200° ± 20°)/ min
Sample (size) length : 0 to 200 mm adjustable
Sample width : 15 mm
Measuring range : 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Accuracy : ± 1 %
Measurement range : 0 to 200 mm
Specimen size : 15×250 mm
Division value : 1 mm
Number of specimen holders : 5
Metal Cylinder inner area : (100 ± 0.2) cm2
Metal Cylinder height : 50 mm
Metal roller width : (200 ± 0..5) mm
Metal roller weight : (10 ± 0.5) kg
Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode : Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability : ≤ 0.1 within 30 min
Accuracy : Chromaticity co-ordinate 0.0001
Sample (size) length : Diameter ≥30 mm, Thickness ≤ 40 mm
System : D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source : D65 as illuminating source
Zero drift : ≤ 0.1 %
The maximum temperature : 300°C
Temperature fluctuation : Within ± 0.5°C
Temperature uniformity : Within ± 1°C
Rotate speed of the turntable : 11 r/min to 12r/min, turntable dimension diameter: 285 mm
Impact Speed & Energy (charpy) : 2.9 m/s for 1J, 2J, 4J, 5J & 3.8 m/s for 7.5J, 15J, 25J
Impact energy (Izod) : 3.5 m/s for 1J, 2J, 4J, 5J, 7.5J, 15J, 25J
Resolution of impact energy : 0.001 J
Pendulum up angle : 160°
Temperature range : 10 to 35°C
Maximum falling height : 2000 mm
Resolution of displacement : 1 mm
Height error : < ± 2 mm
Maximum Sample Length : 6 inches (152.4mm)
Test Temperature : 23 ℃ ± 2 ℃
Sample Size Range : 16 mm to 152 mm
Anvil Size : 13 mm steel Plate
Seal temperature : Room temperature -250°C
Control accuracy : ± 0.2°C
Dwell time : 0.1 S to 999.9 S
Dwell pressure : 0.05 to 0.7 MPa
Standard roller : 2000 ± 50 g
Testing stations : 3
Dimension (L*W*H) tester : 320×210×550 mm (3 stations)
Weight for stations : 10 kg (3 stations)
Standard roller : 2000 ± 50 g
Testing stations : 6
Dimension (L*W*H) tester : 650×210×550 mm (6 stations)
Weight for stations : 15 kg (6 stations)
Measuring range : 0.01 to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm/ 10 min (MVR), 0.001 to 9.999 g/cm (melt density)
Measuring rate : 0.001 S
Temperature range : 50 to 400°C
Temperature precision : ± 0.5°C
Measuring range : 0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density)
Measuring rate : 0.001 S
Temperature range : 50 to 400°C
Temperature precision : ± 0.5°C
Resolution : 0.1 % O2
Measuring range : 0 to 100 % O2
Precision : ± 0.4 % O2
Response time : < 10 S
Inclined adjustable angle : 0 to 40°
Panel width : 120 mm
Test area width : 80 mm
Standard steel balls : 1/32 to 1 inch
Vacuum degree : 0 to 90 KPa
Accuracy : 1 % FS
Resolution : 0.1 KPa
Vacuum chamber effective size : 270 × 210 mm
Operating temperature : Ambient temperature to 300°C
Heating rate : 50°C/ h (5 ± 0.5°C/ 6 min) , 120°C/ h (12 ± 1°C/ 6 min)
Maximum temp. error with heating speed : ± 5°C under 50°C/ h, ± 1°C under 120°C/ h
Range of deformation : 0 to 10 mm
Test arm weight : 2.5 N
Additional Loads : 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler : 150 mm
Abrasion stroke : 40 ± 0.2 M
Control temperature range : Normal temperature to 200°C
Temperature display resolution : 0.01°C
Temperature control accuracy : ± 0.3°
Calibration accuracy : Mooney value ± 0.5
Temperature tester : Room temperature to 200°C
Temperature display resolution : 0.1°C
Temperature control accuracy : ≤ ± 0.3°C
Rotor speed : 100 times/ min
Temperature Control Range : Room temperature to 200°C
Temperature Control : Computer online control. PID SSR
Minimum Display : 0.1°C
Temperature Error : ± 0.3°C
Temperature range : -60°C to 0°C
Temperature accuracy : ± 0.5°C
Impact speed : 2 m/s ± 0.2 m/s
Temperature fluctuation :
Temperature control range : Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy : ± 0.3 ℃
Impact speed : 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min
Max dimension L × W × H : 910 × 510 × 860 mm
Air supply : 6 bars
Impact temperature range : -80 to + 30 ℃
Sensor : Pt 100, 1/3 DIN
Accuracy : ± 0.5 ℃
Temperature range : RT 50° to 300°
Temperature accuracy : ± 1°
Measuring range : 0.01 to 25 mm
Accuracy : ± 0.01 mm
Mixed capacity : 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature range : RT to 300°C
Temperature control system : PID control
Display : LED display
Test force : 612.5 N, 980 N, 1225 N
Brinell hardness test : 1837.5 N, 2450 N, 4900 N/7350 N, 9800 N, 14700 N/29400 N
Hardness measuring area : 8 to 650 HBW (hard metals steel ball)
Hardness indication : Digital display
Test force : 9.8 N, 49 N, 98 N, 196 N, 294 N, 490 N
Hardness value symbol : HV1, HV5, HV10, HV20, HV30, HV250
Error range in display : ± 3.0 %, ± 2.0 %
Hardness indication : Digital display
Hardness measurement : 5 to 9999 HV
Unit conversion : Nuss, Buscher, Roche
Vickers hardness ruler : HV0.2, HV0.3, HV0.5, HV1, HV2,HV2.5, HV3,HV5,HV10,HV20, HV30
Measurement parameters : 4-digit hardness values, 4-digit diagonal length (D1, D2), Hold time, number of tests, mean value.
Frequency (continually adjustable) : 10 Hz to1280 Hz + 0.01 %
Amplitude acceleration ( at 30m/s2 pk ) : 40 Hz to 320 Hz + 0.3 dB + 1 digit
Amplitude velocity ( at 25mm / sec pk ) : 40 Hz to 320 Hz + 0.5dB +1 digit
Amplitude displacement ( at 50 μm pk-pk ) : 40 Hz to 320 Hz + 0.5 dB + 1 digit
Preliminary test force : 98 N
Total test force : 588, 980, 1471 N
Brinell hardness test : 306, 613, 1839 N
Vickers hardness test : 294, 588, 980 N
Preliminary test force : 98 N
Total test force : 588, 980, 1471 N
Total test force dwell time : 0 to 30 S
Hardness indication : Analogue display
Preliminary test force : 98 N
Total test force : 588, 980, 1471 N
Total test force dwell time : 1 to 30 S
Hardness indication : Digital display
Measurement range : 0 to 80 %
Resolution : 0.1
Accuracy : ± 2 % n (non-saturation condition)
Needle : 280 mm
Measurement range : 0 to 90 %
Resolution : 0.1 or 0.01
Accuracy : ± 5 % n (non-saturation condition)
Needle : 235 mm
Measurement range : 0 to 60 %
Resolution : 0.1
Accuracy : ± 5 % n (non-saturation condition)
Needle : 280 mm
Measuring range : 0.001 to 9999
Stability : A (absorbency of light)
Linearity error :
Repeatability error : A (absorbency of light)
Measuring range : 0.001 to 9999
Stability : A (absorbency of light)
Linearity error :
Repeatability error : A (absorbency of light)
Salinity Measurement range : 0.00 to 19.99 ms/cm
Measuring accuracy : EC ± 2% full scale
Temperature Measurement range : -5 to 50°C
Temperature accuracy : ± 0.5°C
Cup capacity : 1 L
Cup Material : Stainless Steel
Speed : 26,000 rpm
IP rating : IPX2
Maximum load : 100 kg ( kg and N can be switched automatically)
Resolution : 0.01 g
Accuracy : ± 0.5 %
Measuring depth : 0 to 40 mm
Maximum load : 100 kg ( kg and N can be switched automatically)
Resolution : 0.01 g
Accuracy : ± 0.5 %
Measuring depth : 0 to 450 mm
Measuring range : 0 to 100 kPa
Resolution : 0.01 kPa
Accuracy : ± 1 kPa
Soil temperature measuring range : -55 to 105°C
Load : (530 ± 10) g
Scale : (0.1 to 10) mm
Working principle : Hand pressure
Dimension : 13.6 × 48.5 × 16.8 mm
Unit : Kg/cm2 (×105 pa)
Division Value : 0.01 Kg/cm2
Indication Error : ± 0.5%
Accuracy : ± 1%
Transformer Capacity : 10 KVA
Booster Capacity : 3 KVA
Input Voltage : AC 220 V
Output Voltage : AC 0 to 100 KV DC 0 to 100 KV
Maximum Testing Force : 300 KN
Accuracy of Test Force : ±1%
Constant Pressure Error : ±1%
Range of Testing Force : 0.5% to 100% KN
Maximum Force : 50 kN
Speed range : 0.01 mm/min to 500 mm/min
Test Resolution : Max force 1/300000
Test Force measurement range : 2% to 100%
Maximum Testing Force : 20KN
Tester Precision : > 0.5 KN
Testing Force Range : 2% to 100%FS
Force Relative Deviation : ± 0.5%
Testing Force Range : 2% to 100% FS
Maximum Testing Force : 600 KN
Force Indication Value : ±1%
Max Stretching Space : 520mm
Maximum Testing Force : 10 kN
Tester Precision Level : > 0.5
Range of Testing Force : 2% to 100% FS
Relative Force Indication Deviation : ± 0.5% within indication
Maximum Capacity : 500N, 1000N, 2500N, 5000N, 10000N
Test Speed Range : 0.001 to 1000mm/min, error ≤±1%
Effective Stroke : 1100mm
Stroke Resolution : 0.001 mm
Maximum Capacity : 100N, 200N, 500N,1KN, 2KN, 2.5KN
Stretch Speed : 0.001 to 500mm/min
Effective stroke : 600 mm
Test Method : CRE Principle
Class of Testing Machine : 1
Maximum Testing Force : 1000kN
Efficient Measure Range : 2% to 100% FS
Relative Value Display Accuracy : ±1%
Testing Range : 40.5, 43, 45( adjustable)
Extension Elongation : 0.5 to 20.5cm
Testing Accuracy : 0.01 cm
Specimen Specification : 2.5×25 cm
Test Stations : 10 stations
Maximum Pressure : 16MPa
Control Mode : Computer control
Pump Capacity : 11L/min
Measurement Range : 1kPa to 500kPa
Measurement Accuracy : 0.2% F. S
Pressure Display Resolution : 0.01kPa
Sensor Test Accuracy : ≤ 1% (5% to 100% within the full-scale range of a single sensor)
Measuring Range : 10 to 500 N
Specimen Holding Force : 2300 ± 500 N
Gas Source : ≥ 0.5MPa
Gauge Pressure : 0.3 to 0.45Mpa
Test Force : 10GF (0.098N), 25GF (0.245N), 50GF (0.49N), 100GF (0.98N), 200GF (1.96N), 300GF (2.94N), 500GF (4.9N), 1Kgf (9.8N)
Hardness Test Range : 8 to 2900HV
Measurement Resolution : 0.01µm
Conversion Scale : Rockwell, Brinell
Hardness Testing Range : HRA:20-88, HRB:20-100, HRC:20-70, HRD:40-77, HRE:70-100, HRF:60-100, HRG:30-94, HRH:80-100, HRK:40-100, HRL:100-120, HRM:85-115, HRR:114-125
Rockwell Scale : HRA, HRB, HRC, HRD, HRE, HRF, HRG, HRH, HRK, HRL, HRM, HRR, HRP, HRS, HRV
Initial Load of Rockwell : 10kgf (98.07N)
Total Load of Rockwell : 60kgf(588N), 100kgf(980N), 150kgf(1471N)