Labtron Testing Instruments ensure accurate measurement and reliable results for material evaluation across various applications. These instruments feature advanced sensor technology, ensuring consistent performance in diverse testing conditions. They come in multiple types, including hardness testers, paper testing instruments, plastic testing instruments, and wood hardness testers, catering to various industrial and research needs. Their ergonomic designs enhance ease of use, reducing operator fatigue during prolonged testing sessions. Our Testing Instruments are ideal for applications in material analysis, quality assurance, and environmental testing across a range of industries.
Maximum Testing Force: 300 KN
Accuracy of Test Force: ±1%
Constant Pressure Error: ±1%
Range of Testing Force: 0.5% to 100% KN
Hardness measurement: 5 to 9999 HV
Unit conversion: Nuss, Buscher, Roche
Vickers hardness ruler: HV0.2, HV0.3, HV0.5, HV1, HV2,HV2.5, HV3,HV5,HV10,HV20, HV30
Measurement parameters: 4-digit hardness values, 4-digit diagonal length (D1, D2), Hold time, number of tests, mean value.
Unit: Kg/cm2 (×105 pa)
Division Value: 0.01 Kg/cm2
Indication Error: ± 0.5%
Accuracy: ± 1%
Testing Range: 40.5, 43, 45( adjustable)
Extension Elongation: 0.5 to 20.5cm
Testing Accuracy: 0.01 cm
Specimen Specification: 2.5×25 cm
Test Stations: 10 stations
Maximum Pressure: 16MPa
Control Mode: Computer control
Pump Capacity: 11L/min
Measurement Range: 1kPa to 500kPa
Measurement Accuracy: 0.2% F. S
Pressure Display Resolution: 0.01kPa
Sensor Test Accuracy: ≤ 1% (5% to 100% within the full-scale range of a single sensor)
Measuring Range: 500Pa to 200kPa
Accuracy: 0.2% F.S
Rate of Water Pressure Rise: 1 to 100 kPa/min
Sample Testing Area: 100 cm²
Load: (530 ± 10) g
Scale: (0.1 to 10) mm
Working principle: Hand pressure
Dimension: 13.6 × 48.5 × 16.8 mm
Measuring Range: 50 to 1600 kPa
Indicating Accuracy: ± 0.5%
Working Environment: 10 to 35℃, Humidity ≤ 85%
Resolution: 0.1
Measuring Range: 250 to 5600 kPa
Indicating Accuracy: ± 0.5%
Working Environment: 10 to 35℃, Humidity ≤ 85%
Resolution: 1 kPa
Test Force: 10GF (0.098N), 25GF (0.245N), 50GF (0.49N), 100GF (0.98N), 200GF (1.96N), 300GF (2.94N), 500GF (4.9N), 1Kgf (9.8N)
Hardness Test Range: 8 to 2900HV
Measurement Resolution: 0.01µm
Conversion Scale: Rockwell, Brinell
Test Force: 10GF (0.098N), 25GF (0.245N), 50GF (0.49N), 100GF (0.98N), 200GF (1.96N), 300GF (2.94N), 500GF (4.9N), 1Kgf (9.8N)
Hardness Test Range: 8 to 2900HV
Measurement Resolution: 0.01µm
Conversion Scale: Rockwell, Brinell
Test Force: 0.245, 0.49, 0.98, 1.96, 2.94, 4.98 N
Minimum Test Unit: 0.01 µm
Hardness Test Range: 40 to 700 HK
Test Force Application Method: Automatic (loading, holding, unloading)
Frequency (continually adjustable): 10 Hz to1280 Hz + 0.01 %
Amplitude acceleration ( at 30m/s2 pk ): 40 Hz to 320 Hz + 0.3 dB + 1 digit
Amplitude velocity ( at 25mm / sec pk ): 40 Hz to 320 Hz + 0.5dB +1 digit
Amplitude displacement ( at 50 μm pk-pk ): 40 Hz to 320 Hz + 0.5 dB + 1 digit
Hardness Testing Range: HRA:20-88, HRB:20-100, HRC:20-70, HRD:40-77, HRE:70-100, HRF:60-100, HRG:30-94, HRH:80-100, HRK:40-100, HRL:100-120, HRM:85-115, HRR:114-125
Rockwell Scale: HRA, HRB, HRC, HRD, HRE, HRF, HRG, HRH, HRK, HRL, HRM, HRR, HRP, HRS, HRV
Initial Load of Rockwell: 10kgf (98.07N)
Total Load of Rockwell: 60kgf(588N), 100kgf(980N), 150kgf(1471N)
Hardness Testing Range: HR15N:70-94, HR30N:42-86 HR45N:20-77, HR15TW:67-93, HR30TW:29-82, HR45TW:10-72
Rockwell Scale: HR15N, HR30N, HR45N, HR15TW, HR30TW, HR45TW
Initial Load of Rockwell: 3kgf(29.42N)
Total Load of Rockwell: 15Kgf(147.1N) 30Kgf(294.2N) 45Kgf(441.3N)
Hardness Testing Range: HR15N:70-94, HR30N:42-86 HR45N:20-77, HR15TW:67-93, HR30TW:29-82, HR45TW:10-72
Rockwell Scale: HRA, HRB, HRC, HRD, HRE, HRF, HRG, HRH, HRK, HRL, HRM, HRR, HRP, HRS, HRV
Initial Load of Rockwell: 3kgf(29.42N)
Total Load of Rockwell: 15Kgf(147.1N) 30Kgf(294.2N) 45Kgf(441.3N)
Hardness Testing Range: HR15N:70-94, HR30N:42-86 HR45N:20-77, HR15TW:67-93, HR30TW:29-82, HR45TW:10-72
Rockwell Scale: 15N, 15T, 15W, 15X, 15Y, 30N, 30T, 30W, 30X, 30Y, 45N, 45T, 45W, 45X, 45Y
Initial Load of Rockwell: 3kgf(29.42N)
Total Load of Rockwell: 15Kgf(147.1N) 30Kgf(294.2N) 45Kgf(441.3N)
Hardness Testing Range: HRA:20-88, HRB:20-100, HRC:20-70, HRD:40-77, HRE:70-100, HRF:60-100, HRG:30-94, HRH:80-100, HRK:40-100, HRL:100-120, HRM:85-115, HRR:114-125
Rockwell Scale: HRA, HRB, HRC, HRD, HRE, HRF, HRG, HRH, HRK, HRL, HRM, HRR, HRP, HRS, HRV
Initial Load of Rockwell: 10kgf (98.07N)
Total Load of Rockwell: 60kgf(588N) 100kgf(980N) 150kgf(1471N)
Hardness Testing Range: HRA:20-88, HRB:20-100, HRC:20-70, HRD:40-77, HRE:70-100, HRF:60-100, HRG:30-94, HRH:80-100, HRK:40-100, HRL:100-120, HRM:85-115, HRR:114-125
Rockwell Scale: HRA, HRB, HRC, HRD, HRE, HRF, HRG, HRH, HRK, HRL, HRM, HRR, HRP, HRS, HRV
Initial Load of Rockwell: 10kgf (98.07N)
Total Load of Rockwell: 60kgf(588N) 100kgf(980N) 150kgf(1471N)
Hardness Testing Range: HRA:20-88, HRB:20-100, HRC:20-70, HRD:40-77, HRE:70-100, HRF:60-100, HRG:30-94, HRH:80-100, HRK:40-100, HRL:100-120, HRM:85-115, HRR:114-125
Rockwell Scale: HRA, HRB, HRC, HRD, HRE, HRF, HRG, HRH, HRK, HRL, HRM, HRR, HRP, HRS, HRV
Initial Load of Rockwell: 10kgf (98.07N)
Total Load of Rockwell: 60kgf(588N) 100kgf(980N) 150kgf(1471N)
Hardness Testing Range: HR15N:70-94, HR30N:42-86 HR45N:20-77, HR15TW:67-93, HR30TW:29-82, HR45TW:10-72
Rockwell Scale: 15N, 15T, 15W, 15X, 15Y, 30N, 30T, 30W, 30X, 30Y, 45N, 45T, 45W, 45X, 45Y
Initial Load of Rockwell: 3kgf(29.42N)
Total Load of Rockwell: 15Kgf(147.1N) 30Kgf(294.2N) 45Kgf(441.3N)
Initial Load of Rockwell: 10kgf (98.07N)
Total Load of Rockwell: 60kgf (588N), 100kgf (980N), 150kgf (1471N)
Hardness Testing Range: HRA: 20 to 88, HRB: 20 to 100, HRC: 20 to 70, HRD: 40 to 77, HRE: 70 to 100, HRF: 60 to 100, HRG: 30 to 94, HRH: 80 to 100, HRK: 40 to 100, HRL: 100 to 120, HRM: 85 to 115, HRR: 114 to 125
Rockwell Scale: HRA, HRB, HRC, HRD, HRE, HRF, HRG, HRH, HRK, HRL, HRM, HRR, HRP, HRS, HRV
Initial Testing Force: 10 N (98.07 N)
Main Test Force: 60(588N), 100(980N), 150(1471N)
Microscope Magnification: 50x, 100x
Automatic Z-axis: Yes
Measuring Range: 10 to 500 N
Specimen Holding Force: 2300 ± 500 N
Gas Source: ≥ 0.5MPa
Gauge Pressure: 0.3 to 0.45Mpa
Measuring Range: 0.0 to 14.0 pH
Accuracy: ±0.1 pH
Repeatability: ±0.1 pH
Resolution: 0.1 pH
Cup capacity: 1 L
Cup Material: Stainless Steel
Speed: 26,000 rpm
IP rating: IPX2
Test Force: Up to 62.5 Kgf (612.94 N)
Brinell Scale: HBW1/1, HBW1/2.5, HBW1/5, HBW2.5/6.25, HBW1/10, HBW2.5/15.625, HBW5/25, HBW1/30, HBW2.5/31.25, HBW2.5/62.5, HBW5/62.5
Resolution: 0.1 HBW
Carried standard: BSEN 6506, ISO 6506, ASTM E10, GB/T231
Test Force (Kgf): 62.5 kgf (612.9 N), 100 kgf (980.7 N), 125 kgf (1226 N), 187.5 kgf (1839 N), 250 kgf (2452 N), 500 kgf (4903 N), 750 kgf (7355 N), 1000 kgf (9807 N), 1500 kgf (14710 N), 3000 kgf (29420 N)
Brinell Scale: HBW2.5/62.5, HBW2.5/187.5, HBW5/62.5, HBW5/125, HBW5/250, HBW5/750, HBW10/100, HBW10/250, HBW10/500, HBW10/1000, HBW10/1500, HBW10/3000
Carried Standard: BSEN 6506, ISO 6506, ASTM E10, GB/T231
Test Force Accuracy: 62.5–250 kgf ≤1%, 500–3000 kgf ≤0.5%
Test Force (Kgf): 62.5 kgf (612.9 N), 100 kgf (980.7 N), 125 kgf (1226 N), 187.5 kgf (1839 N), 250 kgf (2452 N), 500 kgf (4903 N), 750 kgf (7355 N), 1000 kgf (9807 N), 1500 kgf (14710 N), 3000 kgf (29420 N)
Brinell Scale: HBW2.5/62.5, HBW2.5/187.5, HBW5/62.5, HBW5/125, HBW5/250, HBW5/750, HBW10/100, HBW10/250, HBW10/500, HBW10/1000, HBW10/1500, HBW10/3000
Test Force Accuracy: 62.5 to 250 kgf ≤1%, 500 to 3000 kgf ≤0.5%
Measuring Device Resolution: 0.1 µm
Brinell Hardness Scale: HBW2.5/62.5 to HBW10/3000
Experimental Force: 62.5 KGF (612.9 N) to 3000 KGF (29420 N)
Load Retention Time: 0 to 99 s
Digital Imaging: Industrial-grade digital camera
Test Force Range: 62.5 kgf (612.9 N), 100 kgf (980.7 N), 125 kgf (1226 N), 187.5 kgf (1839 N), 250 kgf (2452 N), 500 kgf (4903 N), 750 kgf (7355 N), 1000 kgf (9807 N), 1500 kgf (14710 N), 3000 kgf (29420 N)
Hardness Scales: HBW2.5/62.5, HBW2.5/187.5, HBW5/62.5, HBW5/125, HBW5/250, HBW5/750, HBW10/100, HBW10/250, HBW10/500, HBW10/1000, HBW10/1500, HBW10/3000
Pressure Head: Dual pressure head
Test Force Accuracy: ≤1% (62.5 kgf to 250 kgf) ≤0.5% (500 kgf to 3000 kgf)
Test Force Range: 62.5 kgf (612.9 N), 100 kgf (980.7 N), 125 kgf (1226 N), 187.5 kgf (1839 N), 250 kgf (2452 N), 500 kgf (4903 N), 750 kgf (7355 N), 1000 kgf (9807 N), 1500 kgf (14710 N), 3000 kgf (29420 N)
Hardness Scales: HBW2.5/62.5, HBW2.5/187.5, HBW5/62.5, HBW5/125, HBW5/250, HBW5/750, HBW10/100, HBW10/250, HBW10/500, HBW10/1000, HBW10/1500, HBW10/3000
Pressure Head: Three pressure heads
Automatic Turret: Yes
Maximum Force: 50 kN
Speed range: 0.01 mm/min to 500 mm/min
Test Resolution: Max force 1/300000
Test Force measurement range: 2% to 100%
Maximum Testing Force: 20KN
Tester Precision: > 0.5 KN
Testing Force Range: 2% to 100%FS
Force Relative Deviation: ± 0.5%
Testing Force Range: 2% to 100% FS
Maximum Testing Force: 600 KN
Force Indication Value: ±1%
Max Stretching Space: 520mm
Maximum Testing Force: 10 kN
Tester Precision Level: > 0.5
Range of Testing Force: 2% to 100% FS
Relative Force Indication Deviation: ± 0.5% within indication
Maximum Capacity: 500N, 1000N, 2500N, 5000N, 10000N
Test Speed Range: 0.001 to 1000mm/min, error ≤±1%
Effective Stroke: 1100mm
Stroke Resolution: 0.001 mm
Maximum Capacity: 100N, 200N, 500N,1KN, 2KN, 2.5KN
Stretch Speed: 0.001 to 500mm/min
Effective stroke: 600 mm
Test Method: CRE Principle
Class of Testing Machine: 1
Maximum Testing Force: 1000kN
Efficient Measure Range: 2% to 100% FS
Relative Value Display Accuracy: ±1%
Transformer Capacity: 10 KVA
Booster Capacity: 3 KVA
Input Voltage: AC 220 V
Output Voltage: AC 0 to 100 KV DC 0 to 100 KV
Maximum Load: 15,000 N
Load Display Accuracy: 1 N
Press Depth Accuracy: 1 µm
Adjustable Press Depths: 5.64 mm or 2.82 mm
The maximum temperature: 300°C
Temperature fluctuation: Within ± 0.5°C
Temperature uniformity: Within ± 1°C
Rotate speed of the turntable: 11 r/min to 12r/min, turntable dimension diameter: 285 mm
Impact Speed & Energy (charpy): 2.9 m/s for 1J, 2J, 4J, 5J & 3.8 m/s for 7.5J, 15J, 25J
Impact energy (Izod): 3.5 m/s for 1J, 2J, 4J, 5J, 7.5J, 15J, 25J
Resolution of impact energy: 0.001 J
Pendulum up angle: 160°
Test arm weight: 2.5 N
Additional Loads: 2.5 ± 0.1 N, 5 ± 0.1 N, 10 ± 0.1 N,
Idler: 150 mm
Abrasion stroke: 40 ± 0.2 M
Test Force: 612.5 N, 980 N, 1225 N, 1837.5 N, 2450 N, 4900 N/7350 N, 9800 N, 14700 N/29400 N
Hardness Measuring Area: 8 to 650 HBW (hard metals steel ball)
Hardness Indication: Digital display
Ball Indenter: 2.5, 5, 10 mm
Test Force: 9.8 N, 49 N, 98 N, 196 N, 294 N, 490 N
Hardness Value Symbol: HV1, HV5, HV10, HV20, HV30, HV250
Error Range In Display: ± 3.0 %, ± 2.0 %
Hardness Indication: Digital Display
Temperature range: 10 to 35°C
Maximum falling height: 2000 mm
Resolution of displacement: 1 mm
Height error: < ± 2 mm
Maximum Sample Length: 6 inches (152.4mm)
Test Temperature: 23 ℃ ± 2 ℃
Sample Size Range: 16 mm to 152 mm
Anvil Size: 13 mm steel Plate
Seal temperature: Room temperature -250°C
Control accuracy: ± 0.2°C
Dwell time: 0.1 S to 999.9 S
Dwell pressure: 0.05 to 0.7 MPa
Standard roller: 2000 ± 50 g
Testing stations: 3
Dimension (L*W*H) tester: 320×210×550 mm (3 stations)
Weight for stations: 10 kg (3 stations)
Standard roller: 2000 ± 50 g
Testing stations: 6
Dimension (L*W*H) tester: 650×210×550 mm (6 stations)
Weight for stations: 15 kg (6 stations)
Measuring range: 0.01 to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm/ 10 min (MVR), 0.001 to 9.999 g/cm (melt density)
Measuring rate: 0.001 S
Temperature range: 50 to 400°C
Temperature precision: ± 0.5°C
Measuring range: 0.01to 600.00 g/ 10 min (MFR), 0.01 to 600.00 cm3/ 10 min (MVR), 0.001 to 9.999 g/ cm3 (melt density)
Measuring rate: 0.001 S
Temperature range: 50 to 400°C
Temperature precision: ± 0.5°C
Control temperature range: Normal temperature to 200°C
Temperature display resolution: 0.01°C
Temperature control accuracy: ± 0.3°
Calibration accuracy: Mooney value ± 0.5
Temperature tester: Room temperature to 200°C
Temperature display resolution: 0.1°C
Temperature control accuracy: ≤ ± 0.3°C
Rotor speed: 100 times/ min
Temperature Control Range: Room temperature to 200°C
Temperature Control: Computer online control. PID SSR
Minimum Display: 0.1°C
Temperature Error: ± 0.3°C
Resolution: 0.1 % O2
Measuring range: 0 to 100 % O2
Precision: ± 0.4 % O2
Response time: < 10 S
Sample (size) length: Diameter ≥30 mm, Thickness ≤ 40 mm
Measurement mode: Diffuse reflection factor Rx, Ry, Rz, stimulus value Y10, X10, Z10, chromaticity coordinates x10, y10, z10; lightness L *, chroma a * b *, chroma C * ab, hue angle h * ab, dominant wavelength λd, excitement purity Pe, color difference ΔE * ab, lightness difference ΔL *, chroma difference ΔC * ab, hue difference ΔH * ab, Hunter system L , A, b
Stability: ≤ 0.1 within 30 min
Accuracy: Chromaticity co-ordinate 0.0001
Sample (size) length: Diameter ≥30 mm, Thickness ≤ 40 mm
System: D/0 lighting geometrical viewing conditions, diffuser diameter (d) 150mm, testing hole diameter 30mm
Light source: D65 as illuminating source
Zero drift: ≤ 0.1 %
Sample (size) length: 38×70 mm
Measuring range: (1-500) mN.m (divided into 7 small ranges)
Indication error: 0.02
Test speed: (200° ± 20°)/ min
Sample (size) length: 90 to 200 mm
Sample width: 15 mm, 25 mm, 50mm
Measuring range: 0 to 30, 0 to 100 N,0 to 300 N
Accuracy: ± 1 %
Sample (size) length: 180 mm (180, 150, 100, 90, 50 mm adjustable)
Sample width: 15 mm
Measuring range: 0 to 30, 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Accuracy: ± 1 %
Sample (size) length: 0 to 200 mm adjustable
Sample width: 15 mm
Measuring range: 0 to 30 N (tissue paper), 0 to 100 N,0 to 300 N, 0 to 500 N, 0 to 1000 N
Accuracy: ± 1 %
Measurement range: 0 to 100° SR
Sealed testing speed: 100 ± 10 mm/s
Volume of distilled water: 1000 ± 5 ml
Draining time: 149 ± 1 s
Measurement range: 0 to 200 mm
Specimen size: 15×250 mm
Division value: 1 mm
Number of specimen holders: 5
Metal Cylinder inner area: (100 ± 0.2) cm2
Metal Cylinder height: 50 mm
Metal roller width: (200 ± 0..5) mm
Metal roller weight: (10 ± 0.5) kg
Sample diameter: 125 mm
Sample error: ± 0.2 mm
Sample Thickness: 0.1 to 1.0 mm
Dimension: 240×288×435 mm
Measurement range: 0.01 to 10 N
Slider weight: 200 g
Slider size: 63×63 mm
Testing accuracy: ± 2 %
Testing speed: 200° ± 20° / min
Test range: 1 to 10000 mN
Indicating Error: ± 1 %
Testing length: 5, 10, 15, 20, 25, 50 mm
Measuring range: 0 to 4 mm
Accuracy: 0.01 or 0.001 mm
Gauge: Analogue gauge display
Contact pressure (to create false weight): 100 ± 10 kPa
Measuring range: 0 to 20 mm
Accuracy: 0.01 mm
Gauge: Analogue gauge display
Contact pressure (to create false weight): 20 ± 0.5 kPa
Measuring range: 0 to 5 mm
Division value: 0.001 mm
Measuring parallelism: ≤ 0.002 mm
Indication error: ± 0.0025 mm or ± 0.5 %
Sample size (L*B): 230×50 mm (can join short samples together)
Rub pressure: 20 ± 0.2 N
Friction speed: 43 times / min
Friction area (L*B): 155×50 mm
Sample width: 15 mm
Sample maximum length: 300 mm
Parallelism: ≤ 0.1 mm
Dimension: 240×520×70 mm
Measuring range: 10 to 1000 mN
Division value: 1 mN
Accuracy: ± 1%
Indicating Error: ≤ 0.5
Measuring range: 0.1 to 10 kN
Indication error: < ± 1%
Platen Size: 500×500 mm (customized)
Operating stroke: 500 mm (customized)
Measuring range: 1 to 50 kN
Indication error: < ± 1%
Platen Size: 800×800 mm/ 1000×1000 mm/ 1200×1200 mm/ 1500×1500 mm (customized)
Operating stroke: 800 mm/ 1000 mm/ 1200 mm/ 1500 mm (customized)
Measuring range: 0 to 1000 ml/min
Test area: 10 ± 0.02 cm2
Area differential pressure: 1 ± 0.01 kPa
Inner diameter of grip ring: 35.68 ± 0.05 mm
Measuring Range: A file: 20 to 500 J/m² B file: 500 to 1000 J/m²
Specimen Size: 25.4mm × 25.4mm
Sample Clamping Force: 0 to 400N (adjustable)
Impact Angle: 90°
Measuring range: A (1 to 6) J indicating error ± 0.05 J B (1 to 12) J indicating error ± 0.05 J C (1 to 24) J indicating error ± 0.05 J D (1 to 48) J indicating error ± 0.05 J The indicating errors w.r.t measurement range of 20 to 80 %
Frictional resistance:
Pyramid dimension: Three sides: 60×60×60 mm, height 25 ± 0.7 mm, Arris edge fillet radius 1.5 ± 0.1 mm
Dimension: 800×470×840 mm
Measuring range: 0 to 1000 mN
Resolution: 0.1 mN
Indication error: ± 1 %
Tearing arm: 104 ± 1 mm
Capacity: 10 -16000 mN
Resolution: 0.1 mN
Tearing arm: 104 ± 1 mm
Tearing angle: 27.5° ± 5°
Measurement range: 0 to 5600 kPa
Accuracy: ± 0.5 % F.S.
Compression speed: 170 ± 15 ml/min
Clamp pressure: ≥ 690 kPa
Measurement range: 50 to 1600 kPa-paper and 50 to 5600 kPa-paper
Resolution: 0.01 kPa
Accuracy: ≤± 0.5 %
Compression speed: 95 ± 5 ml/min
Measurement range: 5 to 500 N, 50 to 3000 N
Resolution: 1 N
Accuracy: ± 1 %
Variability: ≤ 1 %
Measuring scope: ( 1 to 9999) s, divided in to (1 to 15) s, (15 to 300) s, (300 to 9999) s, the automatic (no. more than 200 s)
Accuracy: ±0.1 s within 300 s
Vacuum system volume (ml): Bigger volume: 380 ± 1 Smaller volume: 38 ± 1
Contact pressure: 100 ± 2 kPa
Measuring scope: 0 to 99999 s
Folding angle: 135° ± 2°
Tensile scope: 4.9 to 14.7 N
Folding head suture size: 0.25 mm, 0.50 mm, 0.75 mm, 1.00 mm
Inclined adjustable angle: 0 to 40°
Panel width: 120 mm
Test area width: 80 mm
Standard steel balls: 1/32 to 1 inch
Temperature range: -60°C to 0°C
Temperature accuracy: ± 0.5°C
Impact speed: 2 m/s ± 0.2 m/s
Temperature fluctuation:
Temperature control range: Room temperature to -70 ℃ (room temperature ≤ 25 ℃)
Temperature accuracy: ± 0.3 ℃
Impact speed: 0℃ to -30℃ around 2.5 ℃/min -30℃ to -40℃ around 2.5 ℃/min -40℃ to -70℃ around 2.0 ℃/min
Max dimension L × W × H: 910 × 510 × 860 mm
Air supply: 6 bars
Impact temperature range: -80 to + 30 ℃
Sensor: Pt 100, 1/3 DIN
Accuracy: ± 0.5 ℃
Preliminary Test Force: 98 N
Total Test Force: 588, 980, 1471 N
Total Test Force Dwell Time: 0 To 30 S
Hardness Indication: Analogue Display
Preliminary Test Force: 98 N
Total Test Force: 588 N, 980 N, 1471 N
Total Test Force Dwell Time: 1 to 30 S
Hardness Indication: Digital display
Preliminary Test Force: 98 N
Total Test Force: 588 N, 980 N, 1471 N
Brinell Hardness Test: 306 N, 613 N, 1839 N
Vickers Hardness Test: 294 N, 588 N, 980 N
Mixed capacity: 0.5 to 1 kg, 2 to 3 kg, 5 to 7 kg
Temperature range: RT to 300°C
Temperature control system: PID control
Display: LED display
Temperature range: RT 50° to 300°
Temperature accuracy: ± 1°
Measuring range: 0.01 to 25 mm
Accuracy: ± 0.01 mm
Maximum load: 100 kg ( kg and N can be switched automatically)
Resolution: 0.01 g
Accuracy: ± 0.5 %
Measuring depth: 0 to 40 mm
Maximum load: 100 kg ( kg and N can be switched automatically)
Resolution: 0.01 g
Accuracy: ± 0.5 %
Measuring depth: 0 to 450 mm
Measurement range: 0 to 80 %
Resolution: 0.1
Accuracy: ± 2 % n (non-saturation condition)
Needle: 280 mm
Measurement range: 0 to 90 %
Resolution: 0.1 or 0.01
Accuracy: ± 5 % n (non-saturation condition)
Needle: 235 mm
Measurement range: 0 to 60 %
Resolution: 0.1
Accuracy: ± 5 % n (non-saturation condition)
Needle: 280 mm
Soil Moisture Content Measurement Range: 0 to 100 % (m3/m3)
Soil Moisture Content Measurement Resolution: 0.1%
Soil Moisture Content Measurement Sensitivity: ± 0.01% (m3/m3)
Soil Moisture Content Measurement Accuracy: 0 to 50% (m3/m3) ± 2 % (m3/m3) 50% to 100% (m3/m3) ± 3 % (m3/m3)
Measuring range: 0.001 to 9999
Stability: A (absorbency of light)
Linearity error:
Repeatability error: A (absorbency of light)
Measuring range: 0.001 to 9999
Stability: A (absorbency of light)
Linearity error:
Repeatability error: A (absorbency of light)
Salinity Measurement range: 0.00 to 19.99 ms/cm
Measuring accuracy: EC ± 2% full scale
Temperature Measurement range: -5 to 50°C
Temperature accuracy: ± 0.5°C
Measuring range: 0 to 100 kPa
Resolution: 0.01 kPa
Accuracy: ± 1 kPa
Soil temperature measuring range: -55 to 105°C
Structure: Table Type
Maximum Deformation Measurement Range: 1mm (Vicat Test); 0.33mm (Thermal Deformation)
Display: 7-inch Touch Screen
Sample Frame: Manual
Vacuum degree: 0 to 90 KPa
Accuracy: 1 % FS
Resolution: 0.1 KPa
Vacuum chamber effective size: 270 × 210 mm
Address:Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608