Labtron offers high-quality water Purification systems that provide ultra-pure water for different types of laboratory applications. Our ranges include type I, type II, Type III, deionized, UV, RO, and other types of water purification systems. Our systems are equipped with advanced filtration technologies, which effectively remove impurities, contaminants, and microorganisms, ensuring consistent and reliable water quality. Their compact design allows for convenient installation in any laboratory setting, optimizing space without compromising performance.
Output: 30 L/hour
Flow Rate: Up to 2 L/minute
Pure Water Outlet: 2 (Reverse osmosis water, Deionized water)
Deionized Water Resistivity: 16 to 18.2 M Ω cm
Water Output Rate: 90 L/h
Water Flow Rate: 1.5 L/min
Water Source: Urban tap water: TDS < 200ppm
Operating Water Pressure: 0.1 to 0.4 MPa
Output: 30 liters/hour
Flow rate: Up to 2 liters/minute (with pressure tank)
Pure water outlet: 2 reverse osmosis water, deionized water
Deionized Water Quality: Resistivity: 16 to 18.2 M Ω cm Bacteria: N/A Particle (>0.1 µm): N/A
Water Output Rate: 10L/Hr
Water Flow Rate: 2L/Min
Inlet Water Pressure: 0.15 to 0.5mpa
Water Temperature: 5 to 40°C
Water Output Rate: 90 L/Hr
Inlet Water Pressure: 0.15 to 0.5 MPa
Tank Capacity: 40 L
Inlet Water Temperature: 5 to 40°C
HCIO Water Production: 2000ml/min ± 10%
Water Tank: 40L (built-in)
Main Sterilizing Ingredient: hypochlorous acid
Available Chlorine Content: 10mg/L to 20mg/L
Output of Pure water: ≥ 10 L / hr.
Water Type: Type III
Configuration: Benchtop
Process: Single Pass RO system
Output of Pure water: ≥ 20 L / hr.
Water Type: Type III
Configuration: Benchtop
Process: Single Pass RO system
Output of Pure water: ≥ 30 L / hr.
Water Type: Type III
Configuration: Benchtop
Process: Single Pass RO system
Output of Pure water: ≥ 40 L / hr.
Water Type: Type III
Configuration: Floor Standing
Process: Single Pass RO system
Output of Pure water: ≥ 50 L / hr.
Water Type: Type III
Configuration: Floor Standing
Process: Single Pass RO system
Output of Pure water: ≥ 10 L / hr.
Water Type: Type III
Configuration: Benchtop
Process: Double Pass RO system
Output of Pure water: ≥ 20 L / hr.
Water Type: Type III
Configuration: Benchtop
Process: Double Pass RO system
Output of Pure water: ≥ 30 L / hr.
Water Type: Type III
Configuration: Benchtop
Process: Double Pass RO system
Output of Pure water: ≥ 40 L / hr.
Water Type: Type III
Configuration: Floor Standing
Process: Double Pass RO system
Output of Pure water: ≥ 50 L / hr.
Water Type: Type III
Configuration: Floor Standing
Process: Double Pass RO system
Output of pure water: ≥20 L/h
Water type: III type
Configuration: Desktop
Pressure water tank capacity: 24.6 L (approx.)
Output of Pure water: ≥ 10 L / hr.
Water Type: Type I and Type III
Water Tank capacity: 30 L
Configuration: Benchtop
Output of Pure water: ≥ 20 L / hr.
Water Type: Type I and Type III
Water Tank capacity: 30 L
Configuration: Benchtop
Output of Pure water: ≥ 30 L / hr.
Water Type: Type I and Type III
Water Tank capacity: 30 L
Configuration: Benchtop
Output of Pure water: ≥ 40 L / hr.
Water Type: Type I and Type III
Water Tank capacity: 80 L
Configuration: Floor Standing
Output of Pure water: ≥ 50 L / hr.
Water Type: Type I and Type III
Water Tank capacity: 80 L
Configuration: Floor Standing
Output of Pure water: ≥ 10 L / hr.
Water Type: Type I and Type III
Water Tank capacity: 30 L
Configuration: Benchtop
Output of Pure water: ≥ 20 L / hr.
Water Type: Type I and Type III
Water Tank capacity: 30 L
Configuration: Benchtop
Output of Pure water: ≥ 30 L / hr.
Water Type: Type I and Type III
Water Tank capacity: 30 L
Configuration: Benchtop
Output of Pure water: ≥ 40 L / hr.
Water Type: Type I and Type III
Water Tank capacity: 80 L
Configuration: Floor Standing
Output of Pure water: ≥ 50 L / hr.
Water Type: Type I and Type III
Water Tank capacity: 80 L
Configuration: Floor Standing
Water production rate: ≥ 30 L/h
Water intake rate: 1.5 to 1.8 L/min
Temperature: 5 to 40°C
Humidity: 10% to 80%
Output of Pure water: ≥ 10 L / hr.
Process: Single Pass RO system
Configuration: Benchtop
Water Tank capacity: 30 L
Output of Pure water: ≥ 20 L / hr.
Process: Single Pass RO system
Configuration: Benchtop
Water Tank capacity: 30 L
Output of Pure water: ≥ 30 L / hr.
Process: Single Pass RO system
Configuration: Benchtop
Water Tank capacity: 30 L
Output of Pure water: ≥ 40 L / hr.
Process: Single Pass RO system
Configuration: Floor Standing
Water Tank capacity: 80 L
Output of Pure water: ≥ 50 L / hr.
Process: Single Pass RO system
Configuration: Floor Standing
Water Tank capacity: 80 L
Output of Pure water: ≥ 10 L / hr.
Process: Double Pass RO system
Configuration: Benchtop
Water Tank capacity: 30 L
Output of Pure water: ≥ 20 L / hr.
Process: Double Pass RO system
Configuration: Benchtop
Water Tank capacity: 30 L
Output of Pure water: ≥ 30 L / hr.
Process: Double Pass RO system
Configuration: Benchtop
Water Tank capacity: 30 L
Output of Pure water: ≥ 40 L / hr.
Process: Double Pass RO system
Configuration: Floor standing
Water Tank capacity: 80 L
Output of Pure water: ≥ 50 L / hr.
Process: Double Pass RO system
Configuration: Floor Standing
Water Tank capacity: 80 L
Feed Water: Tap Water , TDS ≤ 400 ppm, Water Temperature: 5 to 40°C
Water Production Rate: ≥ 10 L/ h, Ultrapure Water Flow Rate 2 L/ min
Water Quality (Two Stage): Ultrapure water: Resistivity: 18.25 MΩ.cm at 25°C conforms to ASTM CAP NCCLS
Free Chlorine: < 3 ppm
Output of Pure water: ≥ 10 L / hr.
Process: Single Pass RO system
Water Type: Type II
Water Tank capacity: 30 L
Output of Pure water: ≥ 20 L / hr.
Process: Single Pass RO system
Water Type: Type II
Water Tank capacity: 30 L
Output of Pure water: ≥ 30 L / hr.
Process: Single Pass RO system
Water Type: Type II
Water Tank capacity: 30 L
Output of Pure water: ≥ 40 L / hr.
Process: Single Pass RO system
Water Type: Type II
Water Tank capacity: 80 L
Output of Pure water: ≥ 50 L / hr.
Process: Single Pass RO system
Water Type: Type II
Water Tank capacity: 80 L
Output of Pure water: ≥ 10 L / hr.
Process: Double Pass RO system
Water Type: Type II
Water Tank capacity: 30 L
Output of Pure water: ≥ 20 L / hr.
Process: Double Pass RO system
Water Type: Type II
Water Tank capacity: 30 L
Output of Pure water: ≥ 30 L / hr.
Process: Double Pass RO system
Water Type: Type II
Water Tank capacity: 30 L
Output of Pure water: ≥ 40 L / hr.
Process: Double Pass RO system
Water Type: Type II
Water Tank capacity: 80 L
Output of Pure water: ≥ 50 L / hr.
Process: Double Pass RO system
Water Type: Type II
Water Tank capacity: 80 L
Water production rate: ≥20 L/h
Water type: I type
Configuration: Desktop
RO pure water tank capacity: 30 L
Water rate: 10 L/hour
Production Speed: 1.5 to 2 L/min
Water Requirements: Urban Tap Water
Inlet Water Pressure: 0.15 to 0.5mpa
Water Rate: 20 L/hour
Production Speed: 1.5 to 2 L/min
Water Requirements: Urban Tap Water
Inlet Water Pressure: 0.15 to 0.5mpa
Water Rate: 30 L/hour
Production Speed: 1.5 to 2 L/min
Water Requirements: Urban Tap Water
Inlet Water Pressure: 0.15 to 0.5mpa
Water Rate: 45 L per hour
Water Requirements: Urban tap water, Inlet water pressure: 0.15 to 0.5 MPa, Water temperature: 5℃ to 40℃
RO Water Ion Rejection Rate: 97% to 99% (when using a new RO membrane)
RO Water Organic Matter Rejection Rate: > 99% when MW > 200 Dalton
Water Rate: 60 L per hour
Water Requirements: Urban tap water, Inlet water pressure: 0.15 to 0.5 MPa, Water temperature: 5℃ to 40℃
RO Water Ion Rejection Rate: 97% to 99% (when using a new RO membrane)
RO Water Organic Matter Rejection Rate: > 99% when MW > 200 Dalton
Water Rate: 90 L per hour
Water Requirements: Urban tap water, Inlet water pressure: 0.15 to 0.5 MPa, Water temperature: 5℃ to 40℃
RO Water Ion Rejection Rate: 97% to 99% (when using a new RO membrane)
RO Water Organic Matter Rejection Rate: > 99% when MW > 200 Dalton
Water Rate: 120 L per hour
Water Requirements: Urban tap water, Inlet water pressure: 0.15 to 0.5 MPa, Water temperature: 5℃ to 40℃
RO Water Ion Rejection Rate: 97% to 99% (when using a new RO membrane)
RO Water Organic Matter Rejection Rate: > 99% when MW > 200 Dalton
Water Rate: 45 L per hour
Water Requirements: Urban tap water, Inlet water pressure: 0.15 to 0.5 MPa, Water temperature: 5℃ to 40℃
RO Water Ion Rejection Rate: 97% to 99% (when using a new RO membrane)
RO Water Organic Matter Rejection Rate: > 99% when MW > 200 Dalton
Water Rate: 60 L per hour
Water Requirements: Urban tap water, Inlet water pressure: 0.15 to 0.5 MPa, Water temperature: 5℃ to 40℃
RO Water Ion Rejection Rate: 97% to 99% (when using a new RO membrane)
RO Water Organic Matter Rejection Rate: > 99% when MW > 200 Dalton
Water Rate: 90 L per hour
Water Requirements: Urban tap water, Inlet water pressure: 0.15 to 0.5 MPa, Water temperature: 5℃ to 40℃
RO Water Ion Rejection Rate: 97% to 99% (when using a new RO membrane)
RO Water Organic Matter Rejection Rate: > 99% when MW > 200 Dalton
Water Rate: 120 L per hour
Water Requirements: Urban tap water, Inlet water pressure: 0.15 to 0.5 MPa, Water temperature: 5℃ to 40℃
RO Water Ion Rejection Rate: 97% to 99% (when using a new RO membrane)
RO Water Organic Matter Rejection Rate: > 99% when MW > 200 Dalton
Water Rate: 45 L per hour
Water Requirements: Urban tap water, Inlet water pressure: 0.15 to 0.5 MPa, Water temperature: 5℃ to 40℃
RO Water Ion Rejection Rate: 97% to 99% (when using a new RO membrane)
RO Water Organic Matter Rejection Rate: > 99% when MW > 200 Dalton
Water Rate: 60 L per hour
Water Requirements: Urban tap water, Inlet water pressure: 0.15 to 0.5 MPa, Water temperature: 5℃ to 40℃
RO Water Ion Rejection Rate: 97% to 99% (when using a new RO membrane)
RO Water Organic Matter Rejection Rate: > 99% when MW > 200 Dalton
Water Rate: 90 L per hour
Water Requirements: Urban tap water, Inlet water pressure: 0.15 to 0.5 MPa, Water temperature: 5℃ to 40℃
RO Water Ion Rejection Rate: 97% to 99% (when using a new RO membrane)
RO Water Organic Matter Rejection Rate: > 99% when MW > 200 Dalton
Water Rate: 120 L per hour
Water Requirements: Urban tap water, Inlet water pressure: 0.15 to 0.5 MPa, Water temperature: 5℃ to 40℃
RO Water Ion Rejection Rate: 97% to 99% (when using a new RO membrane)
RO Water Organic Matter Rejection Rate: > 99% when MW > 200 Dalton
Water Rate: 45 L per hour
Water Requirements: Urban tap water, Inlet water pressure: 0.15 to 0.5 MPa, Water temperature: 5℃ to 40℃
RO Water Ion Rejection Rate: 97% to 99% (when using a new RO membrane)
RO Water Organic Matter Rejection Rate: > 99% when MW > 200 Dalton
Output of Pure water: ≥ 10 L / hr.
Process: Single Pass RO system
Configuration: Benchtop
Water Tank capacity: 30 L
Output of Pure water: ≥ 20 L / hr.
Process: Single Pass RO system
Configuration: Benchtop
Water Tank capacity: 30 L
Output of Pure water: ≥ 30 L / hr.
Process: Single Pass RO system
Configuration: Benchtop
Water Tank capacity: 30 L
Output of Pure water: ≥ 40 L / hr.
Process: Single Pass RO system
Configuration: Floor Standing
Water Tank capacity: 80 L
Output of Pure water: ≥ 50 L / hr.
Process: Single Pass RO system
Configuration: Floor Standing
Water Tank capacity: 80 L
Output of Pure water: ≥ 10 L / hr.
Process: Double Pass RO system
Configuration: Benchtop
Water Tank capacity: 30 L
Output of Pure water: ≥ 20 L / hr.
Process: Double Pass RO system
Configuration: Benchtop
Water Tank capacity: 30 L
Output of Pure water: ≥ 30 L / hr.
Process: Double Pass RO system
Configuration: Benchtop
Water Tank capacity: 30 L
Output of Pure water: ≥ 40 L / hr.
Process: Double Pass RO system
Configuration: Floor standing
Water Tank capacity: 80 L
Output of Pure water: ≥ 50 L / hr.
Process: Double Pass RO system
Configuration: Floor Standing
Water Tank capacity: 80 L
Water Output Rate: 10L/Hr
Water Flow Rate: 1.5 to 2L/min (with pressure barrel)
Water Temperature: 5 to 40°C
Inlet Water Pressure: 0.15 to 0.5mpa
Water Output Rate: 20L/Hr
Water Flow Rate: 1.5 to 2L/min (with pressure barrel)
Water Temperature: 5 to 40°C
Inlet Water Pressure: 0.15 to 0.5mpa
Water Output Rate: 30L/Hr
Water Flow Rate: 1.5 to 2L/min (with pressure barrel)
Water Temperature: 5 to 40°C
Inlet Water Pressure: 0.15 to 0.5mpa
Output of type 2 water: 20 L/H
Output of type 1 water: 1 to 1.5 L/min
Water type: Type 1 & 2
Process: Double pass RO system
Capacity: 10 L per hour
Production Speed: 1.5 to 2 L (with pressure barrel)
Water Requirements: Urban tap water, Inlet pressure: 0.15 to 0.5 MPa, Temperature: 5℃ to 40℃
RO Water Ion Rejection Rate: 97% to 99% (using a new RO membrane)
Water quality: One stage (Type I)
Feed water: RO water /Distilled water Water temperature: 5 ~ 40℃
Resistivity: 18.25 MΩ.cm @ 25 ℃
TOC: < 5ppb
Water quality: Two stage(Type III and type I)
Feed water: Tap waterTDS≤400ppm Water temperature: 5-40℃ Type 3 water ≥10L/h
Conectivity:
Resistivity: 18.25 MΩ.cm @ 25 ℃
Output 2nd stage RO water: 90 liters/hour
Output ultrapure water: Up to 2 liters/minute (when tank is full)
Ultrapure Water Quality: Resistivity (25°C) 18.2 M Ω cm TOC: < 3ppb Bacteria: 0.2 µm):
RO Water Quality: Conductivity 1st stage RO water: Feed water Conductivity ×5 % Conductivity 2nd stage RO water: 1 to 5 µs/cm
Output 2nd stage RO water: 90 liters/hour
Output ultrapure water: Up to 2 liters/minute (when tank is full)
Ultrapure Water Quality: Resistivity (25°C) 18.2 M Ω cm TOC: < 3ppb Bacteria: 0.2 µm):
EDI: Resistivity >10.2 M Ω cm TOC: < 30ppb Silicone rejection rate: >99.9 %
Output (25°C): 15 Litres/hour
Flow rate: Up to 2 litres/minute (with pressure tank)
Pure water outlet: 1 : reverse osmosis water
RO water quality: Ion rejection rate96 to 99 % (with new RO membrane)Organics rejection rate> 99 % (when MW > 200Dalton)Particles and bacteria rejection rate> 99%Bacteria< 0.1 cfu/ml (with optional 0.45+0.1 μm PES terminal filter)Particle( >0.1μm)< 1/ml (with optional 0.45 + 0.1 μm PES terminal filter)
Output (25°C): 30 Litres/hour
Flow rate: Up to 2 litres/minute (with pressure tank)
Pure water outlet: 1 : reverse osmosis water
RO water quality: Ion rejection rate: 96 to 99 % (with new RO membrane)Organics rejection rate: > 99 % (when MW > 200Dalton)Particles and bacteria rejection rate: > 99%Bacteria: < 0.1 cfu/ml (with optional 0.45+0.1 μm PES terminal filter)Particle( >0.1μm): < 1/ml (with optional 0.45 + 0.1 μm PES terminal filter)
Address:Labtron Equipment Ltd., Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom
Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608