Labtron comprises a wide range of Water Testing Equipment for analyzing water quality. They ensure precise measurement of water parameters for data integrity. We provide durable equipment with integrated data logging and connectivity options. These are designed to ensure safety and compliance across industries. Our Water Testing Equipment features user-friendly interfaces and supports effective water management across diverse settings.
pH measurement range : 0.00 to 14.00 pH
pH accuracy : ± 0.01 pH
pH resolution : 0.01 pH
Calibration points : 2 points
pH measurement range : -1.00 to 15.00 pH
pH accuracy : ± 0.01 pH
pH resolution : 0.01 pH
Calibration points : 1-3 points
pH measurement range : -2.000 to 20.000 pH
pH accuracy : ± 0.002 pH
Calibration points : 1-5 points
Calibration solutions : USA, NIST, DIN or user defined
Temperature compensation : 0 to 100°C, 32°F to 212°F Manual or Automatic
Hold function : Manual or automatic endpoint detection
Stability criteria : Standard or High-accuracy
Interval readings : 10, 30, 60 seconds, 10, 30 minutes or Off
pH Range : -2.000 to 20.000 pH
pH Resolution : 0.1, 0.01, 0.001pH
pH Accuracy : ±0.002 pH
pH Calibration Points : Up to 5
Conductivity measurement range : 0 - 20.0, 200.0, 2000 µS / cm, 200.0 mS / cm
Conductivity accuracy : ± 1 % F.S.
Conductivity resolution : 0.01, 0.1, 1
Conductivity calibration solutions : 10 µS / cm , 84 µS / cm, 1413 µS / cm, 12.88 mS / cm, 111.8 mS / cm
Conductivity Range : 0.000 µS/cm to 3000 mS/cm
Conductivity Resolution : 0.001 µS/cm minimum
Conductivity Accuracy : ±0.5% FS
Conductivity Reference Temperature : 5, 10, 15, 18, 20, 25 ºC
Conductivity measurement range : 0.000 μS/cm to 3000mS/cm
Resistivity measurement range : 5.00 Ω·cm to 100.0 MΩ·cm
TDS measurement range : 0.000 mg/L to 1000g/L
Salinity measurement range : 0.00 to 8.00 %
Cell constant : K=0.1, 1, 10
Power requirements : DC 9 V, using AC adapter, AC 220 V, 50 Hz
Dimension (L×W×H) : 210 × 205 × 75 mm
Weight : 1.5 kg
Dissolved oxygen range : 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy : ± 0.5 mg / L
Resolution : 0.1 mg / L
Calibration points : 1 - 2 points
Dissolved oxygen range : 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy : ± 0.2 mg / L
Resolution : 0.01 mg / L
Calibration points : 1 - 2 points
Ion measurement range : K range: 1×106 - 1M, 0.04 -39000 ppm
Ion measurement accuracy : ± 1 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Ion measurement range : Ag range: 1 × 107 - 1 M, 0.01 - 107900 ppm
Ion measurement accuracy : ± 1 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Ion measurement range : Br range: 0 to 19990 g/L
Ion measurement accuracy : 0.005
Ion measurement Resolution : 4 significant digits (expressed in scientific notation)
mV range : 1999.9 to1999.9 mV
Ion measurement range : Br range: 5 × 106 - 1 M, 0.4 - 79900 ppm
Ion measurement accuracy : ± 0.5 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Ion measurement range : Ca range: 0 to 19990 g/L
Ion measurement accuracy : 0.005
Ion measurement Resolution : 4 significant digits (expressed in scientific notation)
mV range : 1999.9 to1999.9 mV
Ion measurement range : Ca range: 5 × 107 - 1 M, 0.02 - 4000 ppm
Ion measurement accuracy : ± 0.5 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Ion measurement range : Cd range: 1×106– 1M, 0.01-11200 ppm
Ion measurement accuracy : ± 1 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Ion measurement range : Cl range: 0 to 19990 g/L
Ion measurement accuracy : 0.005
Ion measurement Resolution : 4 significant digits (expressed in scientific notation)
mV range : 1999.9 to1999.9 mV
Ion measurement range : Cl range: 5 × 106 - 1 M, 1.8 - 35500 ppm
Ion measurement accuracy : ± 0.5 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Ion measurement range : Cn range: 5 × 106 – 0.01 M, 0.2 – 260 ppm
Ion measurement accuracy : ± 1 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Ion measurement range : Cu range: 0 to 19990 g/L
Ion measurement accuracy : 0.005
Ion measurement resolution : 4 significant digits (expressed in scientific notation)
mV range : 1999.9 to 1999.9 mV
Ion measurement range : Cu range: 1×108 - 1M, 0.06-6400 ppm
Ion measurement accuracy : ± 1 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Ion measurement range : F range: 0 to 19990 g/L
Ion measurement accuracy : 0.005
Ion measurement Resolution : 4 significant digits (expressed in scientific notation)
mV range : 1999.9 to1999.9 mV
Ion measurement range : F range: 1 × 106M – saturation, 0.02 ppm to saturation
Ion measurement accuracy : ± 0.5 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Ion measurement range : I range: 0 to 19990 g/L
Ion measurement accuracy : 0.005
Ion measurement resolution : 4 significant digits (expressed in scientific notation)
mV range : 1999.9 to 1999.9 mV
Ion measurement range : I range: 1×108- 1M, 0.06 -127000 ppm
Ion measurement accuracy : ± 1 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Ion measurement range : K range: 0 to 19990 g/L
Ion measurement accuracy : 0.005
Ion measurement resolution : 4 significant digits (expressed in scientific notation)
mV range : 1999.9 to 1999.9 mV
Ion measurement range : Na range: 0 to 19990 g/L
Ion measurement accuracy : 0.005
Ion measurement Resolution : 4 significant digits (expressed in scientific notation)
mV range : 1999.9 to1999.9 mV
Ion measurement range : Na range: 1 × 105 - 1 M, 0.1 - 23000 ppm
Ion measurement accuracy : ± 0.5 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Ion measurement range : NH range: 0 to 19990 g/L
Ion measurement accuracy : 0.005
Ion measurement resolution : 4 significant digits (expressed in scientific notation)
mV range : 1999.9 to 1999.9 mV
Ion measurement range : NH3 range: 1 × 106 - 1 M, 0.02 - 17000 ppm
Ion measurement accuracy : ± 1 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Ion measurement range : NH4 range: 5 × 106 – 1 M, 0.1 – 18000 ppm
Ion measurement accuracy : ± 0.5 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Test Parameters : pH/ISE/Temp. (mV/pX)
pH Range : -2.00 to 20.00 pH
pH Resolution : 0.1, 0.01 pH
pH Accuracy : ±0.01 pH
Ion measurement range : Pb range: 1×108 – 0.1M, 0.2-20700 ppm
Ion measurement accuracy : ± 1 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Ion measurement range : S range: 1×107 - 1M, 0.003-32100 ppm
Ion measurement accuracy : ± 1 % F.S.
Resolution : 0.001, 0.01, 0.1, 1
Calibration points : 2 to 5 points
Water hardness range : 0.05 mmol / L -0.2 mol / L (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
Accuracy : ± 1 % F.S.
Calibration points : 2 to 5 points
Calibration solution : 0.001, 0.01, 0.1 mmol/L, 0.001, 0.01, 0.1 mol/L
Thermal Conductivity Range : 0.0001 to 1.5 w/mk
Operational Temperature : Hot Plate: 100 °C, 90 °C Cold Plate: -10°C,-20°C, -40°C
Accuracy : ± 3%
Precision : 0.2
Conductivity measurement range : 1.0 to 199.9 µS/cm
Type of conductivity : Low range conductivity
Conductivity accuracy : ± 1 % F.S.
Conductivity calibration points : 1 point
Conductivity measurement range : 10 to 1999 µS/cm
Type of conductivity : Mid-range conductivity
Conductivity accuracy : ± 1 % F.S.
Conductivity calibration points : 1 point
Conductivity measurement range : 0.1 to 19.99 mS/cm
Type of conductivity : High range conductivity
Conductivity accuracy : ± 1 % F.S.
Conductivity calibration points : 1 point
Dissolved oxygen range : 0.0 to 20.0 mg/L (or ppm)
Dissolved oxygen accuracy : ± 0.5 mg/L
% of saturation of oxygen : 0.0 to 200.0%
Sensor type : Polarographic dissolved oxygen probe
Sensor type : Platinum sensor
Connector : 6 pin
ORP measurement range : (-999) to 999 mV
ORP accuracy : ± 2 mV
Connector : BNC
ORP measurement range : (-999) to 999 mV
ORP accuracy : ± 2 mV
ORP resolution : 1 mV
pH measurement range : pH range: (-1.00) to 15.00 pH
Shape of electrode : Different electrodes can be connceted via BNC Connector
pH measurement accuracy : ± 0.01 pH
Calibration point : 1 - 3 points
pH measurement range : 0.0 - 14.00 pH
Shape of electrode : Round glass pH electrode
pH measurement accuracy : ± 0.1 pH
Calibration point : 2 points
pH measurement range : 0.0 - 14.00 pH
Shape of electrode : Flat pH electrode
pH measurement accuracy : ± 0.1 pH
Calibration point : 2 points
pH measurement range : 0.0 - 14.00 pH
Shape of electrode : Long distance planar pH electrode
pH measurement accuracy : ± 0.1 pH
Calibration point : 2 points
pH measurement range : pH range: (-1.00) to 15.00 pH
Shape of electrode : Round glass pH electrode
pH measurement accuracy : ± 0.01 pH
Calibration point : 1 - 3 points
pH measurement range : pH range: (-1.00) to 15.00 pH
Shape of electrode : Flat pH electrode
pH measurement accuracy : ± 0.01 pH
Calibration point : 1 - 3 points
pH measurement range : pH range: (-1.00) to 15.00 pH
Shape of electrode : Long distance planar pH electrode
pH measurement accuracy : ± 0.01 pH
Calibration point : 1 - 3 points
pH measurement range : pH range: (-1.00) to 15.00 pH
Shape of electrode : Round glass pH electrode
pH measurement accuracy : ± 0.01 pH
Calibration point : 1 - 3 points
pH measurement range : pH range: (-1.00) to 15.00 pH
Shape of electrode : Flat pH electrode
pH measurement accuracy : ± 0.01 pH
Calibration point : 1 - 3 points
pH measurement range : pH range: (-1.00) to 15.00 pH
Shape of electrode : Long distance planar pH electrode
pH measurement accuracy : ± 0.01 pH
Calibration point : 1 - 3 points
Salinity measurement range : 0.00 to 10.00 ppt
Salinity accuracy : ± 1 % F.S
Conductivity range : 0 - 20.00, 200.0, 2000 µS/cm, 20.00 mS/cm
Calibration solutions : 84 µS/cm, 1413 µS/cm, 12.88 mS/cm
Salinity measurement range : 0.00 to 80.00 ppt
Salinity accuracy : ± 1 % F.S
Conductivity range : 0 - 200.0 µS/cm, 100 - 2000 µS/cm, 20.00 mS/cm
Calibration solutions : 1413 µS/cm, 12.88 mS/cm, 111.8 mS/cm
TDS range : 0 - 20 ppt
TDS accuracy : ± 1 % F.S.
TDS factor : 0.1 to 1.0 (default 0.5)
Calibration points : 1 - 3 points
TDS range : 0.5 - 100.0 ppm
TDS accuracy : ± 1 % F.S.
TDS factor : 0.4 to 1.0 (default 0.5)
Calibration points : 1 point
TDS range : 5 - 1000 ppm
TDS accuracy : ± 1 % F.S.
TDS factor : 0.4 to 1.0 (default 0.5)
Calibration points : 1 point
TDS range : 0.05 - 10.00 ppt
TDS accuracy : ± 1 % F.S.
TDS factor : 0.4 to 1.0 (default 0.5)
Calibration points : 1 point
Dissolved oxygen range : 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen accuracy : ± 0.5 mg / L
Resolution : 0.1 mg / L
Calibration points : 1 - 2 points
Dissolved oxygen range : 0.0 - 20.0 mg / L (or ppm)
Dissolved oxygen accuracy : ± 0.2 mg / L
Resolution : 0.01 mg / L
Calibration points : 1 - 2 points
pH Measurement Range : (-2.000) to 20.000 pH
pH Accuracy : ± 0.002 pH
pH Calibration Points : 1 - 5 points
pH Calibration Solutions : USA, NIST, DIN or user defined
pH mode : pH measurement range (-2.000) to 20.000 pH pH accuracy ± 0.002 pH pH calibration points 1 to 5 points pH calibration solutions USA, NIST, DIN or user defined
ORP measurement : ORP measurement range -1999.9 to 1999.9 mV ORP accuracy ±0.2 mV ORP calibration points 1 point ORP calibration solutions mV & relative mV
Conductivity measurement : Conductivity measurement range 0 to 20.00, 200.0, 2000 µS / cm, 20.00, 200.2 mS / cm Conductivity accuracy ± 0.5 % F.S. Conductivity calibration points 1 to 5 points Conductivity calibration solutions 10 µS / cm, 84 µS / cm, 1413 µS / cm, 12.88mS / cm, 111.8mS / cm Temperature coefficient 0.0 to 10.0 % / °C Compensation modes Linear or pre water Cell constant K = 0.1, 1, 10 or user-defined Normalization temperature 20 °C or 25 °C
TDS measurement : TDS range 0 to 100 ppt. (max. 200 ppt., depending on factor setting) TDS accuracy ± 1 % F.S. TDS factor 0.1 - 1.0 (default 0.5)
Temperature compensation : 0 to 100 °C, 32 to 212 °F, Manual or Automatic
Stability conditions : Low or high
Calibration due : 0 to 31 days
Memory : Stores up to 500 data sets
Temperature compensation : 0 to 100 °C, 32 to 212 °F, Manual or Automatic
Stability conditions : Low or high
Calibration due : 0 to 31 days
Memory : Stores up to 500 data sets
Absorbance Detection Range : 0 to 3Abs
Absorbance Resolution : 0.001Abs
Optical Path Stability : ≤ ±0.005Abs/30min
Operation Repeatability : ≤ ±0.01Abs
pH Range : -2.000 to 20.000 pH
pH Resolution : 0.1, 0.01, 0.001 pH
pH Accuracy : ± 0.002 pH
pH Calibration Points : Up to 8
pH range : (-2.00) to 16.00 pH
pH accuracy : ± 0.01 pH
pH resolution : 0.01 pH
Calibration points : 2 points
pH range : (-2.00) to 20.00 pH
pH accuracy : ± 0.002 pH
pH resolution : 0.1, 0.01, 0.001 pH
Calibration points : 1 - 5 points
Water hardness range : 0.05 mmol / L - 0.2 mol / L (CaCO3) 0 - 19999 mg / L, (CaO) 0 - 11220 mg / L, (boiler) 0 - 400 mmol / L, (Ca) 0 - 8020 mg / L (German degree) 0 - 1122 °dH, (English degree) 0 - 1404 °e, (French degree) 0 - 2000 °f
Accuracy : ± 1 % F.S.
Calibration points : 2 to 5 points
Calibration solution : 0.001, 0.01, 0.1 mmol / L, 0.001, 0.01, 0.1 mol / L
COD Measurement Range : 2 to 10000 mg/ L
COD Measurement Accuracy : < 50 mg/ L, ≤ ± 10% > 50 mg/ L, ≤ ± 5%
COD Minimum Detection Limit : 0.1 mg/ L
COD Measurement Time : 20 minutes
COD Measurement Range : 5 to 5000 mg/ L
COD Measurement Accuracy : < 50 mg/ L, ≤ ± 10% > 50 mg/ L, ≤ ± 5%
COD Minimum Detection Limit : 0.1 mg/ L
COD Measurement Time : 20 minutes
Measuring range (NTU) : 0 to 100, 0 to 200
Minimum readout value (NTU) : 0.01
Calibration point : 2
Sample volume : 18 to 20 ml
Measuring range (NTU) : 0 to 100, 0 to 200, 0 to 500
Minimum readout value (NTU) : 0.01
Calibration point : 3
Sample volume : 18 to 20 ml
Measuring range (NTU) : 0 to 10, 0 to 100, 0 to 200, 0 to 500
Minimum readout value (NTU) : 0.001
Calibration point : 4
Sample volume : 18 to 20 ml
Measuring range (NTU) : 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000
Minimum readout value (NTU) : 0.01
Calibration point : 5
Sample volume : 18 to 20 ml
Measuring range (NTU) : 0 to 10, 0 to 100, 0 to 200, 0 to 500, 0 to 1000
Minimum readout value (NTU) : 0.001
Calibration point : 5
Sample volume : 18 to 20 ml
Measuring range (NTU) : 0 to 10, 0 to 100
Minimum readout value (NTU) : 0.001
Calibration point : 2
Sample volume : 18 to 20 ml
Measuring range (NTU) : 0 to 100
Minimum readout value (NTU) : 0.01, 0.1
Calibration point : 1
Sample volume : 5 to 10 ml
Measuring range (NTU) : 0 to 50, 0 to 100, 0 to 200
Minimum readout value (NTU) : 0.01, 0.1
Calibration point : 3
Sample volume : 5 to 10 ml
Measuring range (NTU) : 0 to 50, 0 to 100, 0 to 200, 0 to 400
Minimum readout value (NTU) : 0.01, 0.1
Calibration point : 4
Sample volume : 5 to 10 ml
Measuring range (NTU) : 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800
Minimum readout value (NTU) : 0.01, 0.1
Calibration point : 5
Sample volume : 5 to 10 ml
Measuring range (NTU) : 0 to 50, 0 to 100, 0 to 200, 0 to 400, 0 to 800, 0 to 1000
Minimum readout value (NTU) : 0.01, 0.1
Calibration point : 6
Sample volume : 5 to 10 ml
Measuring range (NTU) : 0.000 to 20.00, 20.01 to 200.0, 200 to 2000, 2001 to 4000
Minimum readout value (NTU) : 0.001
Calibration point : 1 to 8
Sample volume : 20 to 30 ml
Measuring range (NTU) : 0 to 200
Minimum readout value (NTU) : 0.1
Calibration point : Nil
Sample volume : 5 to 10 ml
Measuring range (NTU) : 0 to 100, 0 to 200
Minimum readout value (NTU) : 0.01, 0.1
Calibration point : 4
Sample volume : 5 to 10 ml
Measuring range (NTU) : 0 to 100, 100 to 400
Minimum readout value (NTU) : 0.01, 0.1
Calibration point : 5
Sample volume : 5 to 10 ml
Measuring range (NTU) : 0 to 100, 100 to 500
Minimum readout value (NTU) : 0.01, 0.1
Calibration point : 6
Sample volume : 5 to 10 ml
Measuring range (NTU) : 0 to 100, 100 to 800
Minimum readout value (NTU) : 0.01, 0.1
Calibration point : 6
Sample volume : 5 to 10 ml
Measuring range (NTU) : 0 to 100, 100 to 1000
Minimum readout value (NTU) : 0.01, 0.1
Calibration point : 7
Sample volume : 5 to 10 ml
Light source : LED/860 nm (Wavelength)
Readings display : LCD
Unit switches : NTU, FTU, EBC, ASBC
Measurement range : 0.00-20.0; 20.01-200; 200.01-1000 NTU
Measuring Range (NTU) : 0 to 1000 NTU
Accuracy : ±0.3 NTU or ±8% NTU
Repeatability :
Calibration Point : 8
pH measurement range : 01.00 to 15.00 pH
pH calibration points : 1 to 3 points
pH Buffer Solutions : USA (pH 4.01, 7.00, 10.01) or NIST (pH 4.01, 6.86, 9.18)
pH accuracy : ± 0.01 pH
Dissolved oxygen range : 0.0 to 20.0 mg / L (or ppm)
Dissolved oxygen Calibration points : 1 - 2 points
Dissolved oxygen accuracy : ± 0.5 mg / L
Dissolved oxygen resolution : 0.1 mg / L
Conductivity measurement range : 0.01 to 20.00, 200.0, 2000 µS/ cm, 20.00, 200.0 mS/ cm
Conductivity calibration points : 1 to 3 points
Conductivity accuracy : ±1 % F.S.
Conductivity resolution : 0.001/ 0.01/ 0.1/ 1
Measurement range : 20000 mg/L 0.01 mg/L ~ 45000 mg/L 0.01 mg/L ~ 120000 mg/L
Measurement accuracy : ± 2 % F.S. of its range ( Depending on the homogeneity of sludge)
Pressure range : ≤ 0.4 Mpa
Flow rate : ≤ 2.5 m/s, 8.2 ft./s
pH Mode : pH range -2.00 to 20.00 pH pH Accuracy ± 0.002 pH pH Resolution 0.1/0.01/0.001 pH, selectable pH Calibration Points 1 to 5 Points pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode : mV Range -1999.9 to 1999.9 mV mV Accuracy ± 0.2 mV mV Resolution 0.1/1 mV, selectable mV Calibration Points 1 Point
Conductivity Mode : Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm Conductivity Accuracy ± 0.5% F.S. Conductivity Resolution 0.01/0.1/1 Conductivity Calibration Points 1 to 5 Points Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm Conductivity Temperature coefficient 0.0 to 10.0 %/°C Compensation mode Linear or Pure Water Cell Constant K=0.1, 1, 10 or Custom Reference temperature 20 or 25°C
TDS Mode : TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt) TDS Accuracy ± 1 % F.S. TDS Factor 0.1 to 1.0 (default 0.5)
pH Mode : pH range -2.00 to 20.00 pH pH Accuracy ± 0.002 pH pH Resolution 0.1/0.01/0.001 pH, selectable pH Calibration Points 1 to 5 Points pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode : mV Range -1999.9 to 1999.9 mV mV Accuracy ± 0.2 mV mV Resolution 0.1/1 mV, selectable mV Calibration Points 1 Point
Conductivity Mode : Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm Conductivity Accuracy ± 0.5% F.S. Conductivity Resolution 0.01/0.1/1 Conductivity Calibration Points 1 to 5 Points Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm Conductivity Temperature coefficient 0.0 to 10.0 %/°C Compensation mode Linear or Pure Water Cell Constant K=0.1, 1, 10 or Custom Reference temperature 20 or 25°C
TDS Mode : TDS Range 0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt) TDS Accuracy ± 1 % F.S. TDS Factor 0.1 to 1.0 (default 0.5)
pH Mode : pH range -2.00 to 20.00 pH pH Accuracy ± 0.002 pH pH Resolution 0.1/0.01/0.001 pH, selectable pH Calibration Points 1 to 5 Points pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
mV Mode : mV Range -1999.9 to 1999.9 mV mV Accuracy ± 0.2 mV mV Resolution 0.1/1 mV, selectable mV Calibration Points 1 Point
Conductivity Mode : Conductivity Range 0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm Conductivity Accuracy ± 0.5% F.S. Conductivity Resolution 0.01/0.1/1 Conductivity Calibration Points 1 to 5 Points Conductivity Solutions 10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm Conductivity Temperature coefficient 0.0 to 10.0 %/°C Compensation mode Linear or Pure Water Cell Constant K=0.1, 1, 10 or Custom Reference temperature 20 or 25°C
Dissolved Oxygen Mode : Dissolved Oxygen Range 0.00 to 20.00 mg/ L Dissolved Oxygen Accuracy ± 0.2 mg/ L Dissolved Oxygen Resolution 0.1/ 0.01 mg/ L, selectable Dissolved Oxygen Calibration Points 1 or 2 Points % Saturation Range 0.0 to 200.0 % with ± 2 % accuracy Pressure correction 60 to 112.5 kPa, 450 to 850 mmHg Salinity correction 0 to 50 g/ L
pH Mode : pH range -2.00 to 20.00 pH pH Accuracy ± 0.002 pH pH Resolution 0.1/0.01/0.001 pH, selectable pH Calibration Points 1 to 5 Points pH Buffer Solutions USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers
ORP Mode : mV Range ± 2000 mV mV Accuracy ± 0.2 mV mV Resolution 0.1 mV, selectable mV Calibration Points 1 Point, only for relative mode
Ion Mode : Ion measurement range 0.01 to 30000 ppm, mg/l, mol/l, mmol/l (refer Range of ion selection) Ion measurement accuracy ±0.5% F.S (Monovalent), ±1% F.S (Divalent) Ion measurement resolution 0.001/0.01/0.1/1 Ion measurement calibration points 2 to 5 points Ion measurement calibration solutions 0.001/0.01/0.1/1/10/100/1000/10000 ppm, mg/L, mol/L Ion measurement methods Direct reading, Known addition, Known subtraction, Sample addition, Sample subtraction
Water Hardness Mode : Water hardness measurement range 0.05-200mmol/L, 0-1120°dH, 0-1404°e, 0-2000°fH, 0-8000mg/L (Ca2+), 0~19999mg/L (CaCO3) Water hardness measurement accuracy ±1% F.S Water hardness measurement resolution 0.001/0.01/0.1/1 Water hardness calibration points 2 to 5 points Water hardness calibration solutions 0.01/0.1/1/10/100 mmol/L
pH : Range -2.00 to 20.00pH Resolution 0.1, 0.01 pH Accuracy ±0.01 pH Calibration Points Up to 5 Standard Customization Yes Standard Recognition NIST, GB, USA and DIN buffers Slope Limit Yes
Ion Measurement : Unit μg/L, mg/L, g/L, mmol/L, and PX Methods Fˉ, Clˉ, Brˉ, Iˉ, NO³ˉ, BF⁴ˉ, NH⁴⁺, K⁺, Na⁺, Ca²⁺, Cu²⁺, Pb²⁺, Ag⁺
mV : Range -2000.0 to 2000.0 mV Resolution 0.1 mV Accuracy ±0.3 mV or ±0.1%
pX : Range -2.00 to 20.00 pX Resolution 0.1, 0.01 pX Accuracy ±0.01 pX Calibration Points Up to 5
Determination range : 0 to 35 mg/L, 0 to 70 mg/ L, 0 to 350 mg/L, 0 to 700 mg/L (without dilution) 0 to 4000 mg/ L (need to dilute) (subsection measurement)
Measurement error : Less or less than 10 %
Sample container/ bottle quantity : 1 to 6
Sample container/ bottle Capacity : 1000 ml
Temperature compensation : 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Temperature coefficient : Linear
Reference temperature : 25 °C
Stability conditions : Low or high
Temperature compensation : 0 to 100 °C, Manual or Automatic
Temperature coefficient : Linear and Pure water compensation
Reference temperature : 20 °C or 25 °C
Stability conditions : Low or high
Temperature compensation : 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Temperature coefficient : Linear and Pure water compensation
Reference temperature : 20 °C or 25 °C
Stability conditions : Low or high
Temperature compensation : 0 to 100 °C, 32 to 212 ° F, Manual or Automatic
Temperature coefficient : Linear and Pure water compensation
Reference temperature : 20 °C or 25 °C
Stability conditions : Low or high
Range : 0 to 1.0 aw
Resolution : 0 to 1.0 aw
Accuracy : ± 0.02 aw
Sensor : Nonconductive humidity sensor
Measuring range : Water activity 0 to 0.980 aw (no condensing )
Temperature range : 0 to 50°C
Measurement accuracy : ± 0.015 aw
Temperature accuracy : ± 0.5°C
Light source : LED
Wavelength of light : 515 nm
Dimension : 230 × 86 × 47 mm
Power supply : AA Battery or 5V DC 1A
Testing Items : Free Chlorine, Chlorine Dioxide
Testing Range : Free Chlorine: 0.01 to 5.00 mg/L Chlorine Dioxide: 0.02 to 10.00 mg/L
Precision : 3% ± 0.01
Testing Method : DPD Spectrophotometry
Sample volume : 1.2L
Diameter : 4.8inch/118mm
Max. sample depth : 98.4 feet/30m
Point or Profile sampling : Point sampling
HOCl Measuring Range : 0 to 10.00 mg/L
Cl Measuring Range : 0 to 20.00 mg/L
pH Range : 0 to 14 pH
Temperature Range : 0 to 60°C
Measuring principle : Dichromate colorimetric method
COD range : 0.0 to 1500 mg/L
Accuracy : ±8%
Repeatability : 0.03
Measurement range : 0.01 to 20000 mg/L 0.01 to 45000 mg/L 0.01 to 120000 mg/L
Operating temperature : 0 to 50℃(Non-freezing)
Storage temperature : -15 to 60 ℃
Measurement accuracy : Less than the ±5 % of measured value. (Depending on the homogeneity of sludge)
Measurement Range : 0.001 to 100000 mg/L (Customizable)
Measurement Accuracy :
Resolution Rate : 0.001/0.01/0.1/1 mg/L
Sensor Material : SUS316L + POM
Moisture Permeance Layer : 1
Measuring Glass : 8 pieces
Temperature Range : 18℃ to 50 ℃
Temperature Resolution : 0.1℃