Biosafety Cabinet Class II A2 LBS2-A23 offers maximum opening of 550 mm (22 inch) and tested opening of safety height 200 mm (8 inch). Incorporated with interlock function for blower and front window, UV lamp and front window, UV lamp and blower and LED lamp. Built in with foot switch to avoid airflow turbulence caused by arm movement, motorized front window of two layered laminated toughened glass and anti UV, UV lamp for most efficient decontamination and remote control with all functions for easier and convenient operation. Designed with UV life indicator and ULPA Filter, Two in number, 99.999 % efficiency at 0.12 um. Features airflow system of 30% air exhaust and 70 % air recirculation and three protection such as sample, environment and operator.
Request QuoteTested Opening | Safety height of 200 mm (8 inch) |
Maximum Opening | 550 mm (22 inch) |
Inflow Velocity | 0.53 ± 0.025 m/s |
Down Flow Velocity | 0.33 ± 0.025 m/s |
ULPA Filter | Two, 99.999 % efficient at 0.12 um, filter life indicator |
Front Window | Motorized, two-layer laminated toughened glass ≥ 5 mm, anti UV |
Noise | EN12469 ≤ 58 dB / NSF49 ≤ 61 dB |
UV Lamp | 40 W×1 UV timer, UV life indicator, emission of 253.7 nanometres for most efficient decontamination |
Illuminating Lamp | 16 W×2 LED Lamp |
Illumination | ≥ 1000 Lux |
Consumption | 900 W |
Waterproof Sockets | Two, total load of two sockets: 500 W |
Display | LCD display: exhaust filter and down flow filter pressure, filter and UV lamp working time, inflow and down flow velocity, filter life, humidity and temperature, system working time etc. |
Control System | Microprocessor |
Airflow System | 70 % air recirculation, 30 % air exhaust |
Visual and audio alarm | Filter replacement, front window at unsafe height, abnormal airflow velocity |
Material | Work Zone: 304 stainless steel; Main Body: Cold-rolled steel with anti-bacteria powder coating |
Work Surface Height | 750 mm |
Caster | Foot master caster |
Power Supply | AC220V±10 %, 50/60 hz; 110V ± 10 %, 60 hz |
Internal Size (W×D×H) | 1150×600×660 mm |
External Size (W×D×H) | 1700×600×660 mm |
Package Size (W×D×H) | 2000×950×1820 mm |
Gross Weight | 395 kg |
Biosafety Cabinet Class II A2 is widely used in pathology, research laboratories, universities, colleges and hospitals. It is suitable to use for microbiology research in absence of volatile, toxic chemicals and radionuclide.
Sr. No | Name of the Accessory | Unit |
1. | Illumination LED Lamp | 2 |
2. | UV Lamp | 1 |
3. | Base Stand | 1 |
4. | Remote Control | 1 |
5. | Foot Switch | 1 |
6. | Drain Valve | 1 |
7. | Waterproof Sockets | 2 |
Electric Height Adjustable Base Stand
Model | Tested Opening | Maximum Opening | Inflow Velocity | Down Flow Velocity | ULPA Filter | Front Window | Noise | UV Lamp | Illuminating Lamp | Illumination | Consumption | Waterproof Sockets | Display | Control System | Airflow System | Visual and audio alarm | Material | Work Surface Height | Caster | Power Supply | Internal Size (W×D×H) | External Size (W×D×H) | Package Size (W×D×H) | Gross Weight |
LBS2-B20 | Safety Height 200 mm(8 inch) | - | 0.53 ± 0.025 m/s | - | 99.999 % efficiency at 0.12 μm, filter life indicator | Motorized, two-layer laminated toughened glass ≥ 5 mm, anti UV | NSF49 ≤ 61 dB / EN1246949 ≤ 58 dB | 30 W × 1 UV timer, UV life indicator, emission of 253.7 nano meters for most efficient decontamination | LED Lamp 12 W × 2 | ≥ 1000 Lux | 700 W | Two, total load of two sockets 500 W | LCD display, exhaust filter and down flow filter pressure, filter and UV lamp working time, inflow and down flow velocity, filter life, humidity and temperature, system working time etc. | Microprocessor | 0 % air recirculation, 100 % air exhaust | - | - | 750 mm | Foot master caster | - | - | - | - | - |
LBS2-B21 | Safety Height 200 mm(8 inch) | - | 0.53 ± 0.025 m/s | - | 99.999 % efficiency at 0.12 μm, filter life indicator | Motorized, two-layer laminated toughened glass ≥ 5 mm, anti UV | NSF49 ≤ 61 dB / EN1246949 ≤ 58 dB | 30 W × 1 UV timer, UV life indicator, emission of 253.7 nano meters for most efficient decontamination | LED Lamp 14 W × 2 | ≥ 1000 Lux | 850 W | Two, total load of two sockets 500 W | LCD display, exhaust filter and down flow filter pressure, filter and UV lamp working time, inflow and down flow velocity, filter life, humidity and temperature, system working time etc. | Microprocessor | 0 % air recirculation, 100 % air exhaust | - | - | 750 mm | Foot master caster | - | - | - | - | - |
LBS2-B22 | Safety Height 200 mm(8 inch) | - | 0.53 ± 0.025 m/s | - | 99.999 % efficiency at 0.12 μm, filter life indicator | Motorized, two-layer laminated toughened glass ≥ 5 mm, anti UV | NSF49 ≤ 61 dB / EN1246949 ≤ 58 dB | 30 W × 1 UV timer, UV life indicator, emission of 253.7 nano meters for most efficient decontamination | LED Lamp 16 W × 2 | ≥ 1000 Lux | 900 W | Two, total load of two sockets 500 W | LCD display, exhaust filter and down flow filter pressure, filter and UV lamp working time, inflow and down flow velocity, filter life, humidity and temperature, system working time etc. | Microprocessor | 0 % air recirculation, 100 % air exhaust | - | - | 750 mm | Foot master caster | - | - | - | - | - |
LBS2-B23 | Safety Height 200 mm(8 inch) | - | 0.53 ± 0.025 m/s | - | 99.999 % efficiency at 0.12 μm, filter life indicator | Motorized, two-layer laminated toughened glass ≥ 5 mm, anti UV | NSF49 ≤ 61 dB / EN1246949 ≤ 58 dB | 30 W × 1 UV timer, UV life indicator, emission of 253.7 nano meters for most efficient decontamination | LED Lamp 16 W × 2 | ≥ 1000 Lux | 1200 W | Two, total load of two sockets 500 W | LCD display, exhaust filter and down flow filter pressure, filter and UV lamp working time, inflow and down flow velocity, filter life, humidity and temperature, system working time etc. | Microprocessor | 0 % air recirculation, 100 % air exhaust | - | - | 750 mm | Foot master caster | - | - | - | - | - |
LBS2-A30 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
LBS2-A31 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
LBS2-A32 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
LBS2-A33 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
LBS2-A24 | Safety height of 200 mm (8 inch) | 370 mm (15 inch) | 0.53 ± 0.025 m/s | 0.33 ± 0.025 m/s | - | Motorized, toughened glass, anti UV | EN12469 ≤ 58 dB / NSF49 ≤ 61 dB | 15 W×1 UV timer, UV life indicator, emission of 253.7 nanometres for most efficient decontamination | 8 W×2 LED Lamp | ≥ 1000 Lux | 500 W | - | LCD display | Microprocessor | 70 % air recirculation, 30 % air exhaust | Filter replacement, window over height, abnormal air flow velocity | Work Zone: 304 stainless steel Main Body: Cold-rolled steel with anti-bacteria powder coating | 750 mm with optional base | - | AC 220 V ± 10 %, 50/60 Hz; 110 V ± 10 %, 60 Hz | - | - | - | - |
LBS2-A20 | Safety height of 200 mm (8 inch) | 420 mm (17 inch) | 0.53 ± 0.025 m/s | 0.33 ± 0.025 m/s | Two, 99.999 % efficient at 0.12 um, filter life indicator | Motorized, two-layer laminated toughened glass ≥ 5 mm, anti UV | EN12469 ≤ 58 dB / NSF49 ≤ 61 dB | 30 W×1 UV timer, UV life indicator, emission of 253.7 nanometres for most efficient decontamination | 12 W×2 LED Lamp | ≥ 1000 Lux | 760 W | Two, total load of two sockets: 500 W | LCD display: exhaust filter and down flow filter pressure, filter and UV lamp working time, inflow and down flow velocity, filter life, humidity and temperature, system working time etc. | Microprocessor | 70 % air recirculation, 30 % air exhaust | Filter replacement, front window at unsafe height, abnormal airflow velocity | Work Zone: 304 stainless steel; Main Body: Cold-rolled steel with anti-vvbacteria powder coating | 750 mm | Foot master caster | AC 220 V ± 10 %, 50/60 hz; 110 V ± 10 %, 60 hz | 940×600×660 mm | 1100×750×2250 mm | 1220×1000×1840 mm | 243 kg |
LBS2-A21 | Safety height of 200 mm (8 inch) | 420 mm (17 inch) | 0.53 ± 0.025 m/s | 0.33 ± 0.025 m/s | Two, 99.999 % efficient at 0.12 um, filter life indicator | Motorized, two-layer laminated toughened glass ≥ 5 mm, anti UV | EN12469 ≤ 58 dB / NSF49 ≤ 61 dB | 30 W×1 UV timer, UV life indicator, emission of 253.7 nanometres for most efficient decontamination | 12 W×2 LED Lamp | ≥ 1000 Lux | 800 W | Two, total load of two sockets: 500 W | LCD display: exhaust filter and down flow filter pressure, filter and UV lamp working time, inflow and down flow velocity, filter life, humidity and temperature, system working time etc. | Microprocessor | 70 % air recirculation, 30 % air exhaust | Filter replacement, front window at unsafe height, abnormal airflow velocity | Work Zone: 304 stainless steel; Main Body: Cold-rolled steel with anti-bacteria powder coating | 750 mm | Foot master caster | AC220V±10 %, 50/60 hz; 110V ± 10 %, 60 hz | 1150×600×660 mm | 1300×750×2250 mm | 1460×1050×1800 mm | 280 kg |
LBS2-A22 | Safety height of 200 mm (8 inch) | 500 mm (20 inch) | 0.53 ± 0.025 m/s | 0.33 ± 0.025 m/s | Two, 99.999 % efficient at 0.12 um, filter life indicator | Motorized, two-layer laminated toughened glass ≥ 5 mm, anti UV | EN12469 ≤ 58 dB / NSF49 ≤ 61 dB | 40 W×1 UV timer, UV life indicator, emission of 253.7 nanometres for most efficient decontamination | 16 W×2 LED Lamp | ≥ 1000 Lux | 900 W | Two, total load of two sockets: 500 W | LCD display: exhaust filter and down flow filter pressure, filter and UV lamp working time, inflow and down flow velocity, filter life, humidity and temperature, system working time etc. | Microprocessor | 70 % air recirculation, 30 % air exhaust | Filter replacement, front window at unsafe height, abnormal airflow velocity | Work Zone: 304 stainless steel; Main Body: Cold-rolled steel with anti-bacteria powder coating | 750 mm | Foot master caster | AC 220 V ± 10 %, 50/60 hz; 110 V ± 10 %, 60 hz | 940×600×660 mm | 1350×600×660 mm | 1630×1000×1820 mm | 315 kg |
LBS2-A23 | Safety height of 200 mm (8 inch) | 550 mm (22 inch) | 0.53 ± 0.025 m/s | 0.33 ± 0.025 m/s | Two, 99.999 % efficient at 0.12 um, filter life indicator | Motorized, two-layer laminated toughened glass ≥ 5 mm, anti UV | EN12469 ≤ 58 dB / NSF49 ≤ 61 dB | 40 W×1 UV timer, UV life indicator, emission of 253.7 nanometres for most efficient decontamination | 16 W×2 LED Lamp | ≥ 1000 Lux | 900 W | Two, total load of two sockets: 500 W | LCD display: exhaust filter and down flow filter pressure, filter and UV lamp working time, inflow and down flow velocity, filter life, humidity and temperature, system working time etc. | Microprocessor | 70 % air recirculation, 30 % air exhaust | Filter replacement, front window at unsafe height, abnormal airflow velocity | Work Zone: 304 stainless steel; Main Body: Cold-rolled steel with anti-bacteria powder coating | 750 mm | Foot master caster | AC220V±10 %, 50/60 hz; 110V ± 10 %, 60 hz | 1150×600×660 mm | 1700×600×660 mm | 2000×950×1820 mm | 395 kg |
LBS1-A10 | - | - | - | - | - | - | ≤ 60 dB | - | - | - | - | - | - | - | - | - | PMMA | - | - | - | - | - | - | - |
LBS2-A40 | - | - | - | - | - | - | ≤ 65 dB | 30 W | - | ≥1000 Lux | - | - | Color Touch Screen | - | - | - |
Working Area: 304 stainless steel, Side window glass Frame and decorative plate: Cold-rolled steel with anti-bacteria powder coating |
- | - | - | - | - | - | - |