ESR Analyzer LESR-A10 offers a rapid detection rate of 80 samples per hour with a measurement range of 0 to 150mm. It utilizes an infrared detection method for measurement. Samples can be loaded at any moment and measurements can be taken at any desired time. Utilizes advanced optical testing principles to overcome reading errors commonly found in manual methods.
Request QuoteMeasurement Method | Infrared detection |
Analysis Result | Westergren ESR value (mm/hour) |
Measurement Range | 0 to 150mm/h |
Analysis Time | 30 minutes or 60 minutes selectable |
Sampling Interval | 3 min |
Throughput | Maximum 80 tests/hour |
Analysis Channels | 40 |
Loading Capacity | 40 samples at the same time |
Temperature Compensation | Refer to 18℃ automatically (selectable) |
Result Resolution | 1mm/1h and 1mm/2h |
Blood Level Range | 46mm to 64mm |
HCT Range | 0.2 to 1.0 |
Repeatability and Consistency | 0 to 10 mm/h, SD≤ 1.5 mm/h, >10 mm/h, CV≤15% |
Reading Accuracy | 0.2mm |
Coincidence | ≥ 90% |
Display | 7-inch color LCD touchscreen |
Communication Interface | RS232 serial interface |
Printer | Built-in thermal printer |
Power Supply | AC 100 – 240,220V 50/60Hz |
External Size (W × D × H) | 360 × 300 × 180mm |
Package Size (W × D × H) | 395 × 335 × 375mm |
Net Weight | 7.3kg |
Gross Weight | 10Kg |
ESR Analyzer analyses the erythrocyte sedimentation rate analysis, and it is suitable for use in hospital inspection departments, medical laboratories, research institutes, universities, disease control centers, and similar settings.
Related Models :
Model | Measurement Method | Analysis Result | Measurement Range | Analysis Time | Sampling Interval | Throughput | Analysis Channels | Loading Capacity | Temperature Compensation | Result Resolution | Blood Level Range | HCT Range | Repeatability and Consistency | Reading Accuracy | Coincidence | Display | Communication Interface | Printer | Power Supply | External Size (W × D × H) | Package Size (W × D × H) | Net Weight | Gross Weight |
LESR-A11 | - | - | - | - | - | Up to 80 samples per hour | - | - | - | - | - | - | - | - | - | Touch screen LCD display | - | - | - | - | - | - | - |
LESR-A10 | Infrared detection | Westergren ESR value (mm/hour) | 0 to 150mm/h | 30 minutes or 60 minutes selectable | 3 min | Maximum 80 tests/hour | 40 | 40 samples at the same time | Refer to 18℃ automatically (selectable) | 1mm/1h and 1mm/2h | 46mm to 64mm | 0.2 to 1.0 | 0 to 10 mm/h, SD≤ 1.5 mm/h, >10 mm/h, CV≤15% | 0.2mm | ≥ 90% | 7-inch color LCD touchscreen | RS232 serial interface | Built-in thermal printer | AC 100 – 240,220V 50/60Hz | 360 × 300 × 180mm | 395 × 335 × 375mm | 7.3kg | 10Kg |