Chromatography is a powerful analytical tool that is widely used in research, quality control, and various industries. It allows scientists to identify, quantify, and purify substances within complex mixtures, making it an essential technique in fields such as pharmaceuticals, food and beverage, forensics, and environmental monitoring. There are many different types of chromatography, including gas chromatography (GC), gas chromatography-mass spectrometry (GC-MS), ion chromatography (IC), and liquid chromatography-mass spectrometry (LC-MS). Each type of chromatography has its own strengths and weaknesses, and the best type to use will depend on the specific application.

LHLC-A10 HPLC system LHLC-A10

High pressure pump : Single pump

Flow rate range : 0.001 - 9.999 mL / min (0.001 mL / min increment)

Pressure range : ≤ 0.5 MPa (0 - 42 MPa)

Flow rate precision : RSD < 0.06 %

LHLC-A11 HPLC system LHLC-A11

High pressure pump : Two sets of pump

Flow rate range : 0.001 - 9.999 mL / min (0.001 mL / min increments)

Pressure range : ≤ 0.5 MPa (0 - 42 MPa)

Flow rate precision : RSD < 0.06 %

LHLC-B10 HPLC system LHLC-B10

High pressure pump : High pressure gradient pump

Peak operating pressure : 45 MPa, Stainless steel pump

Pressure : ± 0.02 MPa

Flow rate range : 0.001 - 9.999 mL / min

LHLC-B11 HPLC system LHLC-B11

High pressure pump : High pressure constant-current infusion pump

Infusion Way : Micro volume series dual-piston

Infusion pressure : 0 - 9999 Psi

Flow rate : ≤ 0.5 %

LAHS-A10 Analytical HPLC System LAHS-A10

Pump Type : Quaternary Low-Pressure Pump

Pump Flow Rate Range : 0.001 to 10.000 ml/min, in 0.001ml increments

Pump Flow Accuracy : ≤ ± 0.2% (1.00 ml/min, H2 O, R.T., 8.5 MPa)

Pump Flow Precision : RSD ≤ 0.06% (1.00 ml/min, H2 O, R.T., 8.5MPa)

LAHS-D10 Analytical HPLC System LAHS-D10

Pump Flow Range : 0.001 to 10.000mL/min

Pump Set Step : 0.001mL/min

Pump Pressure Range : 0 to 42 MPa

Pump Pressure Pulsation : 0.1MPa (10MPa, C18, methanol 1mL/min)

HPLC-A7832 Analytical HPLC-A7832

Detector Specifications : Model No HPD-A20 HPD-A21 Wavelength range Single wavelength ( 190 to 800 nm ) Dual wavelength ( 190 to 800 nm ) Wavelength accuracy ± 0.5 nm ± 2 nm Wavelength repeatability 0.15 nm 0.3 nm Band width 8 nm 8 nm Optical path 10 nm 10 nm Deuterium lamp 190 to 400 nm 190 to 400 nm Tungsten lamp 400 to 800 nm 400 to 800 nm Baseline noise ( Static ) Au ≤ ± 0.35 × 10-5 ≤ ± 0.5 × 10-5 Baseline drift ( Static ) Au / h ≤ 1 × 10-4 ≤ 1.5 × 10-4 Minimum detection limit ≤ 4 × 10-8 ≤ 4 × 10-8 Power 100 W 100 W Power supply 90 V / 50 to 60 Hz 90 V / 50 to 60 Hz Dimension 460 × 315 × 180 mm 460 × 315 × 180 mm Weight 9.5 kg 9.5 kg

LC-MS-310 Liquid Chromatograph Mass Spectrometer LC-MS-310

Mass Range : m/z 2 to 2,000

Resolution : R < 0.7 u FWHM and adjustable to 0.5 u

Scan Speed : ≥2,0000 amu/s