info@labtron.com +44 2080 043608
HPLC system LHLC-A10

HPLC system LHLC-A10

This HPLC system is equipped with high-pressure constant-current pump and UV detector. Pressure pulsation is controlled by diaphragmatic damper in seconds. The UV detectors helps in identification of samples and elutes that are colourless, odourless in nature. There is auto boot detection function available in this HPLC system.

Request Quote
High pressure pump Single pump
Flow rate range 0.001 - 9.999 mL / min (0.001 mL / min increment)
Pressure range ≤ 0.5 MPa (0 - 42 MPa)
Flow rate precision RSD < 0.06 %
Pulsation ≤ 0.1 MPa (flow rate 1 ml / min, Pressure 5 - 10 MPa)
Qualitative analysis RSD 6 ≤ 0.1 % (naphthalene methyl alcohol solvent)
Quantitative repeatability RSD 6 ≤ 0.3 % (naphthalene methyl alcohol solvent)
Flow rate setting error Ss ≤ 2 % (1 mL / min water, 5 - 10 MPa, room temperature)
Mixing accuracy ± 1 %
Mixing precision ± 0.2 %
Size (W × H × D) 450 × 300 × 160 mm
UV Detector
Wavelength range190 - 680 nm
Flow cell8 µL
Spectrum band width8 nm
Baseline noise≤ ± 0.25 × 10-5 AU (empty cell)
Wavelength accuracy± 1 nm
Baseline drift≤ ± 0.4 × 10-4 AU (empty cell)
Wavelength precision< 0.1 nm
Limit of detection3 × 10-9 g / mL (naphthalene methyl alcohol solvent)
Size (W × H × D)450 × 300 × 160 mm
  • Limit baseline noise can be ensured using electronic pulse suppression technique
  • High pressure single pump
  • Easy to change gasket ring & automatic washing function for the column
  • User-friendly software for smooth operations

The HPLC has applications in separation of mixture of compounds in chemical analysis, poison analysis, environmental analysis, protein food detection, medicine testing, and polymer analysis.

Compare Models

Model High pressure pump Flow rate range Pressure range Flow rate precision Pulsation Qualitative analysis Quantitative repeatability Flow rate setting error Air tightness of the pump Mixing accuracy Mixing precision Size (W × H × D)
LHLC-B11 High pressure constant-current infusion pump 0.001 - 9.999 mL / min (in 0.001 mL / min increments) - - - - - - - - - 260 × 130 × 420 mm
LHLC-A10 Single pump 0.001 - 9.999 mL / min (0.001 mL / min increment) ≤ 0.5 MPa (0 - 42 MPa) RSD < 0.06 % ≤ 0.1 MPa (flow rate 1 ml / min, Pressure 5 - 10 MPa) RSD 6 ≤ 0.1 % (naphthalene methyl alcohol solvent) RSD 6 ≤ 0.3 % (naphthalene methyl alcohol solvent) Ss ≤ 2 % (1 mL / min water, 5 - 10 MPa, room temperature) - ± 1 % ± 0.2 % 450 × 300 × 160 mm
LHLC-A11 Two sets of pump 0.001 - 9.999 mL / min (0.001 mL / min increments) ≤ 0.5 MPa (0 - 42 MPa) RSD < 0.06 % ≤ 0.1 MPa (flow rate 1 ml / min, Pressure 5 - 10 MPa) RSD 6 ≤ 0.1 % (naphthalene methyl alcohol solvent) RSD 6 ≤ 0.3 % (naphthalene methyl alcohol solvent) Ss ≤ 2 % (1 mL / min water, 5 - 10 MPa room temperature) Pressure 42 MPa, 10 min time, Pressure drop < 0.5 MPa ± 1 % ± 0.2 % 450 × 300 × 160 mm
LHLC-B10 High pressure gradient pump 0.001 - 9.999 mL / min - ± 5 % - - - - - - - 520 × 420 × 160 mm

Most Viewed

Customer Enquiry Form

Ask Expert

Address: Labtron Equipment Ltd. Quatro House, Lyon Way, Camberley, Surrey GU16 7ER United Kingdom

Email: info@labtron.com Whatsapp: +44 20 8004 3587 Phone: +44 2080 043608