Octane & Cetane Analyzer LOCT-B10 is a portable device for rapid petroleum products quality monitoring in fields and lab environment conditions. Glass detector has a built in element sensitive to fuel sample temperature detection. The instrument electronic computing module processes detector signals, performs all necessary calculations, and constantly tests the main function modules. It is ideal used in the determination of octane, cetane numbers, our point depressants and break down time in the oil and petroleum industries.
Request QuoteOctane number range | 40 to 125 ON |
Maximum error limit octane number | ±0.5 ON |
Maximum parallel ON difference | ±0.2 |
Antiknock range | 0.5 to 15 % |
Maximum antiknock error limit | 0.001 |
Petrol breakdown time | 50 to 2400 min |
Maximum time error limit | 0.05 |
Volume resistivity | 106 to 1014 Ohm |
Volume error limit | 0.03 |
Cetane number range | 20 to 100 CN |
Maximum error limit cetane number | ±1.0 CN |
Maximum parallel CN difference | ± 0.5 CN |
Diesel pour point error limit | 2˚C |
Kerosene content range | 0 to 50 % |
Kerosene error limit | 0.03 |
Pour-point depressants content | 0.2 to 1 % |
Pour point depressant error limit | 0.0001 |
Oil clarity error limit | 50 to 100 % |
Maximum parallel oil clarity difference | 0.001 |
Dielectric permeability range | 1 to 5 units |
Maximum error limit dielectric permeability | 0.001 units |
Maximum parallel dielectric permeability difference | 0.001 units |
Oils base number range | 3 to 24 unit |
Oil base error limit | 1 BN unit |
Oil voltage measurement range | 5 to 100 kV |
Voltage error limit | 1 kV |
Maximum parallel voltage difference | 0.2 kV |
Oil loss angle tangent range | 0.01 to 40 % |
Loss angle tangent error limit | 0.0001 |
Maximum parallel loss angle tangent difference | 0.001 units |
Mechanical impurities range | 97 % to 100 % |
Mechanical impurities error limit | 0.0001 |
Water in oil content range | 0 % to 30 % |
Water in oil error limit | 0.01 |
Time measurement | 1 sec to 5 sec |
Storage temperature | 5°C to 40°C |
Relative humidity | 98 % RH |
Instrument useful life | 6 |
Voltage supply | 5.4 V |
Dimension | 100 × 210 × 40 mm |
Sensor 1 and 2 | 60 × 100 mm |
Net Weight | 0.68 kg |
Gross weight | 0.85 kg |
Octane & Cetane Analyzer is used in oil and petroleum industries for determination of octane numbers, cetane numbers, petrol breakdown time, antiknock compounds, pour-point depressants, oil clarity, dielectric permeability, kerosene content, oil volume resistivity, etc.
Available Range :
Test Liquids : Diesel, Gasoline Measurement item : motor gasoline and diesel Octane number range : 40 to 125 ONRelated Models :
Model | Octane number range | Maximum error limit octane number | Maximum parallel ON difference | Antiknock range | Maximum antiknock error limit | Petrol breakdown time | Maximum time error limit | Volume resistivity | Volume error limit | Cetane number range | Maximum error limit cetane number | Maximum parallel CN difference | Diesel pour point error limit | Kerosene content range | Kerosene error limit | Pour-point depressants content | Pour point depressant error limit | Oil clarity error limit | Maximum parallel oil clarity difference | Dielectric permeability range | Maximum error limit dielectric permeability | Maximum parallel dielectric permeability difference | Oils base number range | Oil base error limit | Oil voltage measurement range | Voltage error limit | Maximum parallel voltage difference | Oil loss angle tangent range | Loss angle tangent error limit | Maximum parallel loss angle tangent difference | Mechanical impurities range | Mechanical impurities error limit | Water in oil content range | Water in oil error limit | Time measurement | Storage temperature | Relative humidity | Instrument useful life | Voltage supply | Dimension | Sensor 1 and 2 | Net Weight | Gross weight |
LOCT-A10 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | 320 × 250 × 160 mm | - | - | - |
LOCT-A20 | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - | - |
LOCT-B10 | 40 to 125 ON | ±0.5 ON | ±0.2 | 0.5 to 15 % | 0.001 | 50 to 2400 min | 0.05 | 106 to 1014 Ohm | 0.03 | 20 to 100 CN | ±1.0 CN | ± 0.5 CN | 2˚C | 0 to 50 % | 0.03 | 0.2 to 1 % | 0.0001 | 50 to 100 % | 0.001 | 1 to 5 units | 0.001 units | 0.001 units | 3 to 24 unit | 1 BN unit | 5 to 100 kV | 1 kV | 0.2 kV | 0.01 to 40 % | 0.0001 | 0.001 units | 97 % to 100 % | 0.0001 | 0 % to 30 % | 0.01 | 1 sec to 5 sec | 5°C to 40°C | 98 % RH | 6 | 5.4 V | 100 × 210 × 40 mm | 60 × 100 mm | 0.68 kg | 0.85 kg |