LMPWM-A30
|
pH range |
-2.00 to 20.00 pH |
pH Accuracy |
± 0.002 pH |
pH Resolution |
0.1/0.01/0.001 pH, selectable |
pH Calibration Points |
1 to 5 Points |
pH Buffer Solutions |
USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers |
|
- |
mV Range |
-1999.9 to 1999.9 mV |
mV Accuracy |
± 0.2 mV |
mV Resolution |
0.1/1 mV, selectable |
mV Calibration Points |
1 Point |
|
- |
- |
- |
Conductivity Range |
0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm |
Conductivity Accuracy |
± 0.5% F.S. |
Conductivity Resolution |
0.01/0.1/1 |
Conductivity Calibration Points |
1 to 5 Points |
Conductivity Solutions |
10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm |
Conductivity Temperature coefficient |
0.0 to 10.0 %/°C |
Compensation mode |
Linear or Pure Water |
Cell Constant |
K=0.1, 1, 10 or Custom |
Reference temperature |
20 or 25°C |
|
TDS Range |
0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt) |
TDS Accuracy |
± 1 % F.S. |
TDS Factor |
0.1 to 1.0 (default 0.5) |
|
- |
- |
- |
0 to 105°C, 32 to 221°F |
± 0.5°C |
0.1°C |
1 Point |
Manual or Automatic |
Manual or Automatic Endpoint Detection |
Low or High |
1 to 31 Days |
Yes |
Stores Up to 500 data sets |
USB interface |
BNC, 6-pin mini plug |
LCD |
DC5 V, AC 220 V, 50 Hz |
210 × 188 × 60 mm |
1.5 kg |
LMPWM-A31
|
pH range |
-2.00 to 20.00 pH |
pH Accuracy |
± 0.002 pH |
pH Resolution |
0.1/0.01/0.001 pH, selectable |
pH Calibration Points |
1 to 5 Points |
pH Buffer Solutions |
USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers |
|
- |
mV Range |
-1999.9 to 1999.9 mV |
mV Accuracy |
± 0.2 mV |
mV Resolution |
0.1/1 mV, selectable |
mV Calibration Points |
1 Point |
|
- |
- |
- |
Conductivity Range |
0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm |
Conductivity Accuracy |
± 0.5% F.S. |
Conductivity Resolution |
0.01/0.1/1 |
Conductivity Calibration Points |
1 to 5 Points |
Conductivity Solutions |
10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm |
Conductivity Temperature coefficient |
0.0 to 10.0 %/°C |
Compensation mode |
Linear or Pure Water |
Cell Constant |
K=0.1, 1, 10 or Custom |
Reference temperature |
20 or 25°C |
|
TDS Range |
0 to 10.00, 100.0, 1000 ppm, 10.00, 100 ppt (Max. 200 ppt) |
TDS Accuracy |
± 1 % F.S. |
TDS Factor |
0.1 to 1.0 (default 0.5) |
|
Salinity Range |
0 to 10 ppt (maximum 80 ppt) |
Salinity Accuracy |
± 1 % F.S. |
Measurement modes |
Seawater or practical salinity |
|
Resistivity Range |
0 to 100 MΩ |
Resistivity Accuracy |
± 1 % F.S. |
Resistivity Resolution |
0.01, 0.1, 1 |
|
- |
0 to 105°C, 32 to 221°F |
± 0.5°C |
0.1°C |
1 Point |
Manual or Automatic |
Manual or Automatic Endpoint Detection |
Low or High |
1 to 31 Days |
Yes |
Stores Up to 500 data sets |
USB interface |
BNC, 6-pin mini plug |
LCD |
DC5 V, AC 220 V, 50 Hz |
210 × 188 × 60 mm |
1.5 kg |
LMPWM-A32
|
pH range |
-2.00 to 20.00 pH |
pH Accuracy |
± 0.002 pH |
pH Resolution |
0.1/0.01/0.001 pH, selectable |
pH Calibration Points |
1 to 5 Points |
pH Buffer Solutions |
USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers |
|
- |
mV Range |
-1999.9 to 1999.9 mV |
mV Accuracy |
± 0.2 mV |
mV Resolution |
0.1/1 mV, selectable |
mV Calibration Points |
1 Point |
|
- |
- |
- |
Conductivity Range |
0.01 to 20.00, 200.0, 2000 µS/cm, 20.00, 200.0 mS/cm |
Conductivity Accuracy |
± 0.5% F.S. |
Conductivity Resolution |
0.01/0.1/1 |
Conductivity Calibration Points |
1 to 5 Points |
Conductivity Solutions |
10, 84, 1413 µS/cm, 12.88, 111.8 mS/ cm |
Conductivity Temperature coefficient |
0.0 to 10.0 %/°C |
Compensation mode |
Linear or Pure Water |
Cell Constant |
K=0.1, 1, 10 or Custom |
Reference temperature |
20 or 25°C |
|
- |
- |
- |
Dissolved Oxygen Range |
0.00 to 20.00 mg/ L |
Dissolved Oxygen Accuracy |
± 0.2 mg/ L |
Dissolved Oxygen Resolution |
0.1/ 0.01 mg/ L, selectable |
Dissolved Oxygen Calibration Points |
1 or 2 Points |
% Saturation Range |
0.0 to 200.0 % with ± 2 % accuracy |
Pressure correction |
60 to 112.5 kPa, 450 to 850 mmHg |
Salinity correction |
0 to 50 g/ L |
|
0 to 105°C, 32 to 221°F |
± 0.5°C |
0.1°C |
1 Point |
Manual or Automatic |
Manual or Automatic Endpoint Detection |
Low or High |
1 to 31 Days |
Yes |
Stores Up to 500 data sets |
USB interface |
BNC, 6-pin mini plug |
LCD |
DC5 V, AC 220 V, 50 Hz |
210 × 188 × 60 mm |
1.5 kg |
LMPWM-A40
|
pH range |
-2.00 to 20.00 pH |
pH Accuracy |
± 0.002 pH |
pH Resolution |
0.1/0.01/0.001 pH, selectable |
pH Calibration Points |
1 to 5 Points |
pH Buffer Solutions |
USA (pH 4.0/7.00/10.01) or NIST (pH 4.01/6.86/9.18) or DIN buffers |
|
mV Range |
± 2000 mV |
mV Accuracy |
± 0.2 mV |
mV Resolution |
0.1 mV, selectable |
mV Calibration Points |
1 Point, only for relative mode |
|
- |
Ion measurement range |
0.01 to 30000 ppm, mg/l, mol/l, mmol/l (refer Range of ion selection) |
Ion measurement accuracy |
±0.5% F.S (Monovalent), ±1% F.S (Divalent) |
Ion measurement resolution |
0.001/0.01/0.1/1 |
Ion measurement calibration points |
2 to 5 points |
Ion measurement calibration solutions |
0.001/0.01/0.1/1/10/100/1000/10000 ppm, mg/L, mol/L |
Ion measurement methods |
Direct reading, Known addition, Known subtraction, Sample addition, Sample subtraction |
|
Water hardness measurement range |
0.05-200mmol/L, 0-1120°dH, 0-1404°e, 0-2000°fH, 0-8000mg/L (Ca2+), 0~19999mg/L (CaCO3) |
Water hardness measurement accuracy |
±1% F.S |
Water hardness measurement resolution |
0.001/0.01/0.1/1 |
Water hardness calibration points |
2 to 5 points |
Water hardness calibration solutions |
0.01/0.1/1/10/100 mmol/L |
|
Temperature measurement range |
0 to 105°, 32 to 212°F |
Temperature measurement accuracy |
± 0.5°C, ± 0.9°F |
Temperature measurement resolution |
0.1°C, 0.1°F |
Temperature measurement calibration points |
1 point |
|
- |
- |
- |
- |
- |
0 to 100°C, 32 to 221°F |
- |
- |
- |
Manual or Automatic |
Manual or Automatic end point detection |
Standard or high accuracy |
1 to 31 days |
Yes |
Stores up to 1000 sets data |
USB communication interface |
BNC Connector |
7 inch TFT LCD display |
DC 12 V, AC adapter, AC 220 V, 50 Hz |
240 × 220 × 80 mm |
1.7 kg |